¿ä¾à1 |
º» ¿¬±¸´Â ±âȹ´Ü°è¿¡¼ °ÇÃ๰ÀÇ ÀÌ»êÈź¼Ò ¹èÃâ·® Æò°¡¿¡ °³·«Æò°¡¸ðµ¨ÀÎ I-O LCA ¸ðµ¨ÀÇ È°¿ë °¡´É¼ºÀ» ÆÄ¾ÇÇÏ´Â °ÍÀ» ¸ñÀûÀ¸·Î ÇÑ´Ù. À̸¦ À§ÇÏ¿©, I-O LCA ¸ðµ¨°ú Hybrid LCA ¸ðµ¨À» Á¤ÀÇÇϰí, µÎ LCA ¸ðµ¨À» ÀÌ¿ëÇÏ¿© ¾ÆÆÄÆ® 3°³ ´ÜÁö¿Í 3°³ ±³À°½Ã¼³¹°¿¡ ´ëÇÑ ÀÌ»êÈź¼Ò ¹èÃâ·®À» Æò°¡Çϰí, °á°ú¸¦ ºñ±³ÇÏ¿´´Ù. »ç·ÊºÐ¼® °á°ú, I-O LCA ¸ðµ¨À» ÅëÇØ »êÃâµÈ ÀÌ»êÈź¼Ò ¹èÃâ·®Àº Hybrid LCA ¸ðµ¨À» ÅëÇØ »êÃâµÈ ÀÌ»êÈź¼Ò ¹èÃâ·®°ú »ó´çÈ÷ À¯»çÇÏ¿´´Ù. ¾ÆÆÄÆ® ´ÜÁöÀÇ °æ¿ì 78.2-86.3%ÀÇ À¯»çµµ¸¦ ³ªÅ¸³»¾ú°í, Çб³ °ÇÃ๰ÀÇ °æ¿ì 59.9-84.8%ÀÇ À¯»çµµ¸¦ ³ªÅ¸³»¾ú´Ù. ÇÏÁö¸¸, Àü¹ÝÀûÀ¸·Î I-O LCA ¸ðµ¨¿¡ ÀÇÇØ »êÃâµÈ ÀÌ»êÈź¼Ò ¹èÃâ·®Àº Hybrid LCA ¸ðµ¨ÀÇ °á°ú¿¡ ºñÇØ ÀÛ¾Ò´Ù. ±×·³¿¡µµ ºÒ±¸Çϰí, »ç·ÊºÐ¼® °á°ú´Â ÃѰø»çºñ¸¦ À¯ÀÏÇÑ ÀԷ¿ä¼Ò·Î ÇÏ´Â °£´ÜÇÑ ¸ðµ¨ÀÎ, I-O LCA ¸ðµ¨ÀÌ »ó´çÈ÷ ³ôÀº Á¤È®µµ¸¦ °¡Áø´Ù´Â »ç½ÇÀ» º¸¿©ÁÖ¾ú´Ù. I-O LCA ¸ðµ¨Àº ÇÁ·ÎÁ§Æ®ÀÇ Ãʱ⠱âȹ´Ü°è¿¡ °ÇÃ๰ÀÇ ÀÌ»êÈź¼Ò ¹èÃâ·®À» ¿¹ÃøÇϴµ¥ Ȱ¿ëµÉ ¼ö ÀÖÀ» °ÍÀ¸·Î ±â´ëµÈ´Ù. |
¿ä¾à2 |
This study aims to determine whether or not the input output life cycle assessment (I-O LCA) model can be used to assess the carbon dioxide (CO2) emission of buildings in initial planning phase. To ensure this end, this study proposed I-O LCA model which is the simplified LCA model and Hybrid LCA model which is the detailed LCA model, and then assessed and compared the CO2 emission of six case projects (three apartment complexes and three educational facilities) using the two LCA model. The results of the case study showed that the CO2 emissions assessed by the I-O LCA is significantly similar to the CO2 emission assessed by the Hybrid LCA model. The similarity of results from both LCA models was 78.2-86.3% in apartment complexes and 59.9-84.8% in educational facilities. However, the CO2 emissions from I-O LCA model were smaller than the CO2 emissions from Hybrid LCA model in case study. Nevertheless, the case study showed that the I-O LCA model was capable of assessing the CO2 emission of buildings quite appropriately although the I-O LCA model is the simplified LCA model which considers only the construction cost. The I-O LCA model is expected to be a useful tool for assessing the CO2 emission of buildings in initial planning phase. |