건축도시공간연구소

Architecture & Urban Research Institute

pdf원문보기 에러 해결방법 바로가기



문헌홈 > 연구논문 > 상세

[원문보기시 소비되는 포인트 : 100 포인트] 미리보기 인용

한국콘크리트학회|IJCSM 2022년 5월

논문명 Probabilistic Repair Cost Simulation for RC Structures Repaired With Bacteria Coating Material Under Sulfate Attack
저자명 (Hyun-Sub Yoon) ; (Seung-Jun Kwon) ; (Yong-Sik Yoon) ; (Keun-Hyeok Yang)
발행사 한국콘크리트학회
수록사항 IJCSM, Vol.16 No.3 (2022-05)
페이지 시작페이지(365) 총페이지(12)
ISSN 1976-0485
주제분류 재료 / 구조
주제어 ; MFP (maintenance-free period); bacteria repair material; service life; repair cost; maintenance
요약2 Concrete sewage structures are difficult to maintain since they are constructed under the ground and their surfaces inside are exposed to various deteriorations such as acid and sulfate ingress. In this study, their repair costs were evaluated both deterministically and probabilistically considering the extended service life through repairing of conventional repair mortar and a newly developed bacteria repair material. Unlike the conventional deterministic method, the probabilistic manner evaluates repair cost continuously, taking into account variations in the initial service life and extended service life through repair. For the work, variations in the sulfate ion diffusion coefficient and protection parameters (cover depth and repair layer thickness) were obtained experimentally. Based on the target service life (60 years), the repair cost increased to 123% as the maintenance-free period (MFP) decreased by half, and decreased to 77% as the MFP increased to 1.5 times. As the extended service life through repair decreased by half, the repair cost increased to 180% due to the increasing repair frequency. When the repair-extended service life increased to 1.5 times, the repair cost decreased to 73%. Considering exterior sulfate concentrations (120 and 200 ppm) and entire sewage pipelines (3268 m), the bacteria repair material showed the lowest repair cost (1376 K$ and 1498 K$ with the deterministic and probabilistic method, respectively) since the repair-service life increased from 10.4 to 25.3 years and the number of repairs decreased from 9 to 4 due to the low diffusion coefficient of the bacteria repair material.
소장처 한국콘크리트학회
언어 영어
DOI https://doi.org/10.1186/s40069-022-00509-9