°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

´ëÇѰÇÃàÇÐȸ|´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è 2004³â 5¿ù

³í¹®¸í ¹Ù´Ú°øÁ¶½Ã½ºÅÛ°ú õÀå°øÁ¶½Ã½ºÅÛÀÇ ½Ç³»È¯°æ ºñ±³ Æò°¡ / Comparative Evaluation of Indoor Environment of Office Buildings with An Underfloor Air Distribution System and A Ceiling Based Air Conditioning System
ÀúÀÚ¸í À¯±âÇü ; Á¶µ¿¿ì½Äº°ÀúÀÚ ; À¯Áö¿ë½Äº°ÀúÀÚ ; ÀÌÁø¿µ½Äº°ÀúÀÚ ; À̻󿱽ĺ°ÀúÀÚ
¹ßÇà»ç ´ëÇѰÇÃàÇÐȸ
¼ö·Ï»çÇ× ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è, v.20 n.5 (2004-05)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(185) ÃÑÆäÀÌÁö(8)
ISSN 12269093
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î ¹Ù´Ú°øÁ¶½Ã½ºÅÛ ; ½Ç³»È¯°æ ; Underfloor Air Distribution System ; Indoor Environment
¿ä¾à1 º» ¿¬±¸´Â ¹Ù´Ú°øÁ¶½Ã½ºÅÛÀÌ Àû¿ëµÈ »ç¹«¼Ò °Ç¹°À» ´ë»óÀ¸·Î µ¿Àý±â ¹× ÇÏÀý±â¿¡ ÇöÀå ÃøÁ¤ ¹× Àç½ÇÀÚ ¼³¹®Á¶»ç¸¦ ÅëÇÏ¿© ¹Ù´Ú°øÁ¶½Ã½ºÅÛ°ú õÀå°øÁ¶½Ã½ºÅÛÀÇ ºñ±³ Ư¼ºÀ» µµÃâÇϰíÀÚ ÇÑ´Ù. ÃøÁ¤ °á°ú, °Ü¿ïö ½Ç³» ¿Â¿­È¯°æÀÇ °æ¿ì, ¹Ù´Ú°øÁ¶½Ã½ºÅÛÀÌ ÃµÀå°øÁ¶½Ã½ºÅÛ¿¡ ºñÇÏ¿© ¼öÁ÷¿ÂµµºÐÆ÷ Â÷À̵µ Àû°í, Àç½ÇÀÚ ¸¸Á·µµµµ ³ôÀº °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ȯ±âÈ¿À² ÃøÁ¤°á°ú´Â ¹Ù´Ú±Þ±â/õÀåȯ±â ¹æ½ÄÀÇ ¹Ù´Ú°øÁ¶½Ã½ºÅÛÀÌ °Ü¿ïö ¹× ¿©¸§Ã¶ ¸ðµÎ õÀå°øÁ¶½Ã½ºÅÛ¿¡ ºñÇÏ¿© ȯ±âÈ¿À²ÀÌ ³ôÀº °ÍÀ¸·Î ÃøÁ¤µÇ¾ú´Ù. ¹Ù´Ú°øÁ¶½Ã½ºÅÛÀÇ °æ¿ì, °Ü¿ïö ±Þ±â±¸ ÁÖº¯ÀÇ ±â·ù°¨¿¡ ÀÇÇÑ Àç½ÇÀÚ ºÒÄè°¨ÀÌ ³ô¾ÆÁú ¼ö ÀÖ´Â °æ¿ì°¡ ¹ß»ýÇÏ¿© À̰Ϳ¡ ´ëÇÑ °³¼±¹æ¾ÈÀÌ ¿ä±¸µÈ´Ù.
¿ä¾à2 The purpose of this study was to evaluate the indoor environment of office building with??underfloor air distribution system and ceiling based air conditioning system. The underfloor air distribution system was introduced to use access floor and aim to economical motive such as reducing floor to height level. Researches were not sufficient to preserve the characteristics between ceiling based air conditioning system and underfloor air distribution system. Experiments have been carried out to indoor environment in the summer and winter. As the result, thermal environment of the underfloor air distribution system is better than ceiling based air conditioning system in the winter. Ventilation effectiveness of the underfloor air distribution system is bigger than ceiling based air conditioning system.
¼ÒÀåó ´ëÇѰÇÃàÇÐȸ
¾ð¾î Çѱ¹¾î
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
»ï¼ºÀüÀÚ°­³²»ç¿Á¹Ù´Ú°øÁ¶½Ã½ºÅÛ
ÀÌÁ¾Çö - ¼³ºñÀú³Î(´ëÇѼ³ºñ°øÇÐȸÁö) : v.37 n.10 (200810)
[ƯÁý¿ø°í] ÅëÇÕÇü ¹Ù´Ú°øÁ¶ ½Ã½ºÅÛ ¼Ò°³
Á¶È£Á¤ ; ±èÁ¾¹Î ; Á¶Á¾¼± - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.29 n.09 (201209)
ÅëÇÕÇü ¹Ù´Ú°øÁ¶ ½Ã½ºÅÛ
Á¶È£Á¤ ; Á¶Á¾¼± ; ±èÁ¾¹Î ; ÀÌÁ¤Çõ ; ¹ÚÂù¼® - ´ëÇѼ³ºñ°øÇÐȸ ÇϰèÇмú¹ßǥȸ ³í¹®Áý : (201206)
±¹³» ÆÐ½Ãºê°ÇÃ๰ ¼³°è ¹× ½Ã°ø»ç·Ê
À̸íÁÖ - Çѱ¹±×¸°ºôµùÇùÀÇȸ Ãß°èÇмú°­¿¬È¸ ³í¹®Áý : (200911)
[ÁýÁß±âȹ] ½Ç³»°ø±âÁú Çâ»óÀ» À§ÇÑ È¯°æÄ£È­Çü ¹Ù´Ú°øÁ¶½Ã½ºÅÛ
Á¶µ¿¿ì - ¼³ºñÀú³Î(´ëÇѼ³ºñ°øÇÐȸÁö) : v.33 n.8 (200408)
¹Ù´Ú°øÁ¶ ½Ã½ºÅÛÀÌ Àû¿ëµÈ »ç¹«°ø°£ÀÇ °ÅÁÖÈÄ ¼º´ÉÆò°¡
À±¼ºÈÆ ; ÀåÇâÀÎ ; Á¤ÇØ±Ç ; ÃÖ¼±±Ô ; À¯±âÇü - ž翡³ÊÁö(Çѱ¹Å¾翡³ÊÁöÇÐȸ ³í¹®Áý) : v.31 n.6 (201112)
³», ¿Ü´Ü¿­ ½Ã½ºÅÛ Àû¿ë½ÃÀÇ °øµ¿ÁÖÅà ±âÁØÃþ Àü¸é ¿Üº®-½½¶óºê Á¢ÇպΠ¹× Ãøº®-½½¶óºê Á¢ÇպΠ´Ü¿­¼º´É ºñ±³ Æò°¡
¼Û½Â¿µ(Song Seung-Yeong) ; ±¸º¸°æ(Koo Bo-Kyoung) ; ÃÖº¸Çý(Ch i Bo-Hye) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.24 n.8 (200808)
[ƯÁý] ģȯ°æ °ÇÃ๰ÀÇ °³³ä ¹× °èȹ ¹æ¹ý
À±Á¾È£ - °ÇÃàȯ°æ¼³ºñ(Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸÁö) : v.1 n.2 (200710)
¡Û¡Û¾÷¹«½Ã¼³ÀÇ ¹Ù´Ú°øÁ¶ ¼³°è ¹× ±¸Çö»ç·Ê
ÃÖµµ¼® ; Á¤¼öÇö ; À̼ö¿¬ - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (201411)