°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

Çѱ¹»ýÅÂȯ°æ°ÇÃàÇÐȸ|KIEAE Journal 2024³â 2¿ù

³í¹®¸í ±×¸°¸®¸ðµ¨¸µ ´ë»ó °Ç¹°ÀÇ ³Ã³­¹æ ½Ã½ºÅÛ ¿îÀüÇöȲ ½ÇÅÂÁ¶»ç - ³Ã³­¹æ ¼³Á¤¿Âµµ¿Í ü°¨ ¹× ¸¸Á·µµ¸¦ Áß½ÉÀ¸·Î - / A Survey on the Operation Status of Heating and Cooling System in Green Remodeling Buildings - Focused on the Heating and Cooling Set Point Temperature and Comfort and Satisfaction -
ÀúÀÚ¸í ¼º³²Ã¶(Namchul Seong)½Äº°ÀúÀÚ ; È«±¸Ç¥(Goopyo Hong)½Äº°ÀúÀÚ
¹ßÇà»ç Çѱ¹»ýÅÂȯ°æ°ÇÃàÇÐȸ
¼ö·Ï»çÇ× KIEAE Journal, Vol.24 No.1(Åë±Ç 125È£) (2024-02)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(137) ÃÑÆäÀÌÁö(7)
ISSN 2288-968X
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î ±×¸°¸®¸ðµ¨¸µ; °Ç¹° ¿îÀü; ³Ã³­¹æ ¼³Á¤¿Âµµ; ü°¨ ¹× ¸¸Á·µµ; ¼³¹®Á¶»ç ; Green Remodeling; Building Operation; Cooling and Heating Set Point; Feeling and Satisfaction; Survey
¿ä¾à2 Purpose: Green remodeling was performed on public buildings according to government policies to improve the energy performance of old buildings. However, to improve the energy performance of old buildings and save energy, it is very important to operate them properly after remodeling. Therefore, the purpose of this study is to understand the current status and actual condition of the building where green remodeling was performed. Method: A survey was conducted to understand the operating status and actual condition of the building where green remodeling has been completed. The survey was conducted in a total of 8 items to investigate the use of the building, the operating time of the building, the set point temperature of the heating and cooling, the feeling of the building users, and the satisfaction of the heating and cooling system. Result: To summarize the results of the study, As for the use of the building, 36% of daycare centers and 61% of public health centers or hospitals were surveyed. According to a survey of the building's operating hours, 63% of the buildings operated for nine hours. The average cooling set point temperature was 24.8¡É, and the average heating set point temperature was 24.3¡É. When using the heating and cooling system, more than 80% of the respondents said it was 'moderate', and the feeling of the occupants in the building was pleasant. In the satisfaction survey with the remodeled heating and cooling system, 79% of the cooling system and 68% of the heating system were satisfied.
¼ÒÀåó Çѱ¹»ýÅÂȯ°æ°ÇÃàÇÐȸ
¾ð¾î Çѱ¹¾î
DOI https://doi.org/10.12813/kieae.2024.24.1.137
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
2025³â Àǹ«È­ ·Îµå¸Ê¿¡ µû¸¥ °ø°ø½Ã¼³ Á¦·Î¿¡³ÊÁö°ÇÃ๰ ÀÎÁõÁ¦µµ ½ÃÀå ¼ö¿ë¼º
À̽¹Î(Lee, Seung-Min) ; ±èÁøÈ£(Kim, Jin-Ho) ; ½Å±¤¼ö(Shin, Gwang-Su) ; ±èÀÇÁ¾(Kim, Eui-Jong) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.12 No.6 (201812)
±â°èÇнÀ ±â¹Ý ÀÚµ¿È­ ¾Ë°í¸®ÁòÀ» Ȱ¿ëÇÑ °øÁ¶±â ±Þ±â ¿Âµµ ¿¹Ãø
¾ÈÀ¯¼±(Yusun Ahn) ; È«±¸Ç¥(Goopyo Hong) ; ±èº´¼±(Byungseon Sean Kim) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.32 No.1 (202001)
°¡¿ì½Ã¾È ÇÁ·Î¼¼½º ¸ðµ¨À» ÀÌ¿ëÇÑ ³Ã°¢Å¾ ÃÖÀûÁ¦¾î
±èÀç¹Î(Kim, Jae-Min) ; ½ÅÇѼÖ(Shin, Han-Sol) ; ÃßÇѰæ(Chu, Han-Gyeong) ; À̵¿Çõ(Yi, Dong-Hyuk) ; ¹Ú¼ºÈ£(Park, SungHo) ; ¿©¸í¼®(Yeo, Myoung-Souk) ; ¹Úö¼ö(Park, Cheol-Soo) - Ãß°èÇмú¹ßÇ¥´ëȸ : 2018 (201811)
³Ã°¢¼ö À¯·® Á¦¾î¸¦ ÅëÇÑ ³Ã¹æ½Ã½ºÅÛÀÇ ¿¡³ÊÁö Àý°¨ È¿°ú¿¡ °üÇÑ °ËÅä
±èÇý¹Ì(Kim, Hyemi) ; ¼Û¿µÇÐ(Song, Young-hak) - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.37 No.1 (201704)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ´ë¼öÁ¦¾î¸¦ ÅëÇÑ ³Ãµ¿±â °Åµ¿ Ư¼º ¹× ¿¡³ÊÁö Àý°¨ È¿°ú ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; ¼ÕÁ¤Àº(Jeong-Eun Son) ; À̱¤È£(Kwang Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.28 No.04 (201604)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ºÎºÐºÎÇÏÀ² ¹× ³Ã¹æ ¿¡³ÊÁö ¼º´É Ư¼º ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; À¯º´È£(Byeong-Ho Yu) ; À̱¤È£(Kwang-Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.27 No.11 (201511)
°ÇÃ๰ÀÇ ¿¡³ÊÁöÀý¾à¼³°è±âÁØ °­È­¿¡ µû¸¥ ¾÷¹«¿ë °Ç¹°ÀÇ ¿¡³ÊÁö¼º´É °³¼± È¿°ú
±èÁöÇý(Kim, Ji-Hye) ; ¼ºÁ¦Àº(Sung, Jea-Eun) ; ±èÇý±â(Kim, Hye-Gi) ; ¹Ú´öÁØ(Park, Duk-Joon) ; ±è¼±¼÷(Kim, Sun-Sook) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.14 No.1 (202002)
IoTÁ¤º¸±â¹Ý Modelica-EnergyPlus Co-simulationÀ» ÅëÇÑ ¿¡³ÊÁö¼Òºñ·® ÃßÁ¤
±èÇýÁø(Kim, Hye-Jin) ; ¼­µ¿Çö(Seo, Dong-Hyun) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.13 No.5 (201910)
Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner
À̰ÇÈ£(Keon-ho Lee) ; Á¶µ¿¿ì(Dong-woo Cho) ; ±èÇý¹Ì(Hyemi Kim) ; ¼Û¿µÇÐ(Young-hak Song) - ARCHITECTURAL RESEARCH(´ëÇѰÇÃàÇÐȸ ³í¹®Áý) : Vol.19 No.4 (201712)
Blower Door¸¦ ÀÌ¿ëÇÑ ±¹³» ÁÖ°Å¿ë °Ç¹°ÀÇ ±â¹Ðµµ ½ÇÃø »ç·Ê ºÐ¼®
±Ç¿ÀÇö(Kwon Oh-Hyun) ; ±èÁøÈ¿(Kim, Jin-Hyo) ; ±è¹ÎÈÖ(Kim Min-Hwi) ; ¼®À±Áø(Seok Yoon-Jin) ; Á¤Àç¿ø(Jeong Jae-Weon) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.07 (201007)
¡á Á¦ 1 ÀúÀÚÀÇ ´Ù¸¥ ¹®Çå ½Äº°ÀúÀÚ´õº¸±â
ÅëÇÕ ±â°èÇнÀ ±â¹Ý ±Þ±â¿Âµµ ÃÖÀû ¿îÀü¿¡ µû¸¥ HVAC ½Ã½ºÅÛ ¿¡³ÊÁö Àý°¨ È¿°ú ºÐ¼®
¼º³²Ã¶(Namchul Seong) ; ±è´ë¿õ(Daeung Kim) - KIEAE Journal : Vol.26 No.2(Åë±Ç 138È£) (202604)
LSTM ±â¹Ý ¾÷¹«¿ë °Ç¹° ³Ã¹æºÎÇÏ ¿¹Ãø ¸ðµ¨ÀÇ ´Ü°èÀû ¼º´É ÃÖÀûÈ­ ¹æ¹ý
¼º³²Ã¶(Namchul Seong) ; ±è´ë¿õ(Daeung Kim) - KIEAE Journal : Vol.26 No.2(Åë±Ç 138È£) (202604)
¾÷¹«¿ë °Ç¹° ȯ±â½Ã½ºÅÛÀÇ CO2 ³óµµ ¼³Á¤ Á¶°Ç º¯È­¿¡ µû¸¥ ¿¡³ÊÁö ¼º´É ºÐ¼®
¼º³²Ã¶(Namchul Seong) ; ±è´ë¿õ(Daeung Kim) - KIEAE Journal : Vol.26 No.1(Åë±Ç 137È£) (202602)
¸ðµâ·¯ ÃʵîÇб³ °Ç¹°ÀÇ ¿¡³ÊÁö ¼º´É ºÐ¼®
±èÇýÁø;±è´ë¿õ;ÀÌÁ¾¼º;¼º³²Ã¶ - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.45 No.2 (202510)
¸ðµâ·¯ ÃʵîÇб³ °Ç¹°ÀÇ ¿¡³ÊÁö ¼º´É ºÐ¼®
ºí·Î¾î µµ¾î ½ÇÇèÀ» ÅëÇÑ À̵¿½Ä ¸ðµâ·¯ ±³»ç ħ±â·® ºÐ¼®
±èÇýÁø;¼º³²Ã¶;±è´ë¿õ - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.45 No.1 (202504)
ÅëÇÕ ±â°èÇнÀ ¾Ë°í¸®Áò(IMLA)À» ÀÌ¿ëÇÑ °øÁ¶¼³ºñÀÇ ÃÖÀûÁ¦¾î ¹æ¹ý
¼º³²Ã¶;±è´ë¿õ - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.44 No.2 (202410)
°øµ¿ÁÖÅà ³Ã¹æ±â¿Í Àü¿­±³È¯±â µ¿½Ã°¡µ¿ ½Ã ±Þ¡¤¹è±â±¸ À§Ä¡¿¡ µû¸¥ ¿Â¿­ ¼º´É ºÐ¼®
±èÇýÁø;¼º³²Ã¶;±è´ë¿õ - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.44 No.2 (202410)
CFD¸¦ ÀÌ¿ëÇÑ °øµ¿ÁÖÅà Àü¿­±³È¯±â ±Þ¡¤¹è±â±¸ À§Ä¡¿¡ µû¸¥ ȯ±â È¿À²
±èÇýÁø;±è´ë¿õ;¼º³²Ã¶ - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.44 No.1 (202404)
³Ã¹æ¼³ºñ ¿ë·® »êÁ¤À» À§ÇÑ ÃÖ±Ù ±â»óµ¥ÀÌÅÍ ºÐ¼® ¹× ¿Ü±â¿Âµµ »êÁ¤
½ÉÂùÇü;¼º³²Ã¶;È«±¸Ç¥ - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.43 No.2 (202310)