³í¹®¸í Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ Àǹ«È­¿¡ µû¸¥ °øµ¿ÁÖÅà ´ÜÀ§ ³Ã³­¹æºÎÇÏ ±âÁØ¿¡ °üÇÑ ¿¬±¸ / A Study on Unit Heating and Cooling Load Standard for Apartment Houses according to the Mandatory of Zero Energy Building Certification
ÀúÀÚ¸í Á¶È«Àç ; ÃÖ½½°Ç½Äº°ÀúÀÚ ; Ȳµ¿°ï
¹ßÇà»ç ´ëÇѼ³ºñ°øÇÐȸ
¼ö·Ï»çÇ× ¼³ºñ°øÇÐ³í¹®Áý, Vol.35 No.12 (2023-12)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(633) ÃÑÆäÀÌÁö(13)
ISSN 1229-6422
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î °øµ¿ÁÖÅÃ; °ÇÃ๰ÀÇ ¿¡³ÊÁöÀý¾à¼³°è±âÁØ; Åë°èÀû Ç¥Áظðµ¨; ´ÜÀ§ ³Ã³­¹æºÎÇÏ; Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ ; Apartment house; Standard for energy conservation design in buildings; Theoretical reference building model; Unit heating and cooling load; Zero energy building certification
¿ä¾à1 º» ¿¬±¸¿¡¼­´Â °øµ¿ÁÖÅÿ¡ ´ëÇÑ Åë°èÀû Ç¥Áظðµ¨À» ±¸ÃàÇÑ ÈÄ ÇöÇà ¿¡³ÊÁöÀý¾à¼³°è±âÁØ°ú Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ °¡À̵å¶óÀÎ ±âÁØ Àû¿ë¿¡ µû¸¥ ´ÜÀ§ ³Ã³­¹æºÎÇϸ¦ »êÁ¤ÇÏ¿´´Ù. ÀÌÈÄ 17°³ µµ½Ã¿¡ ´ëÇÑ Áö¿ªº°, 3°³ ŸÀÔ¿¡ ´ëÇÑ Àü¿ë¸éÀûº°, 9°³ ŸÀÔÀÇ ¼¼´ë ¹èÄ¡º°, ÇöÇà ¿¡³ÊÁöÀý¾à¼³°è±âÁØ ¹× Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ °¡À̵å¶óÀÎ ±âÁغ°, ³Ã¹æºÎÇÏ ¹× ³­¹æºÎÇÏ ±¸¼º ¿ä¼Òº°·Î ±¸ºÐÇÏ¿© ºÐ¼®À» ÁøÇàÇÏ¿´´Ù. À̸¦ ÅëÇØ µµÃâµÈ °á·ÐÀº ´ÙÀ½°ú °°ÀÌ Á¤¸®ÇÒ ¼ö ÀÖ´Ù.
(1) ±¹³» 17°³ ÁÖ¿ä µµ½Ã¸¦ Áö¿ªº°·Î ºÐ·ùÇÏ¿© »ìÆ캻 °á°ú ´ÜÀ§ ³Ã¹æºÎÇÏÀÇ Áö¿ªº° Â÷À̴ Ưº°ÇÑ °æÇ⼺À» º¸ÀÌÁö ¾Ê´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù. ÇÏÁö¸¸, ´ÜÀ§ ³­¹æºÎÇÏÀÇ °æ¿ì ÁߺÎ1Áö¿ª, ÁߺÎ2Áö¿ª, ³²ºÎÁö¿ª, Á¦ÁÖÁö¿ªÀ¸·Î °¥¼ö·Ï Áö¿ªº° ºÎÇÏ Â÷ÀÌ´Â Áõ°¡ÇÏ´Â °æÇ⼺À» º¸ÀÌ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
(2) °øµ¿ÁÖÅÃÀÇ ´ÜÀ§¼¼´ë Àü¿ë¸éÀû¿¡ µû¸¥ ´ÜÀ§ ³Ã³­¹æºÎÇÏ´Â Àü¿ë¸éÀûÀÌ Áõ°¡ÇÒ¼ö·Ï AVºñ(¿ÜÇǸéÀû ´ë üÀûºñ)°¡ ÀÛ¾ÆÁö¹Ç·Î ´ÜÀ§ ³Ã³­¹æºÎÇÏ´Â ÁÙ¾îµå´Â Ư¡À» º¸¿´´Ù.
(3) ´ÜÀ§ ³Ã¹æºÎÇÏ´Â Ãþº° ¹èÄ¡º¸´Ù´Â Àϻ縦 ¹Þ´Â Ãø¼¼´ë ¶Ç´Â Áß°£¼¼´ë ¹èÄ¡ À¯¹«°¡ ºÎÇÏ°ª¿¡ Å« ¿µÇâÀ» ¹ÌÄ¡´Â °ÍÀ¸·Î ³ªÅ¸³­ ¹Ý¸é ´ÜÀ§ ³­¹æºÎÇÏ´Â °Ç¹°ÀÇ ±¸Á¶Ã¼°¡ ¿ÜºÎ¿Í Á¢ÇÏ´Â ¸éÀûÀÌ Å« ÃÖ»óÃþ, ÃÖÇÏÃþ, Áß°£Ãþ ¹èÄ¡ ¿©ºÎ°¡ ºÎÇÏ°ª¿¡ ´õ Å« ¿µÇâÀ» ÁÖ´Â °ÍÀ¸·Î ³ªÅ¸³µ´Ù.
(4) ÇöÇà ¹ýÀû ¼³°èÁ¶°ÇÀÎ °ÇÃ๰ÀÇ ¿¡³ÊÁöÀý¾à¼³°è±âÁØ¿¡ µû¸¥ ´ÜÀ§ ³Ã¹æºÎÇÏ´Â 55.1~65.1 W/m2·Î ³ªÅ¸³µÀ¸¸ç, ÀÌ´Â ÇöÀç ±¹³»¿¡ Åë¿ëµÇ°í ÀÖ´Â ´ÜÀ§ ³Ã¹æºÎÇÏ ±âÁØÀÎ(KS C 9306) 145 W/m2 ±âÁØ ´ëºñ 55.1~62.0% Àú°¨ÀÌ °¡´ÉÇÒ °ÍÀ¸·Î ÆǴܵȴÙ. ¶ÇÇÑ ´ÜÀ§ ³­¹æºÎÇÏÀÇ °æ¿ì´Â 27.2~31.5 W/m2·Î ÇöÀç Çѱ¹Áö¿ª³­¹æ°ø»ç ?¿­»ç¿ë½Ã¼³±âÁØ? 43.2~46.1 W/m2 ±âÁØ ´ëºñ 31.7~37.0% Àú°¨ÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î º¸ÀδÙ.
(5) ÇöÇà ¿¡³ÊÁöÀý¾à¼³°è±âÁØ ´ëºñ Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ °¡À̵å¶óÀÎ Àû¿ë¿¡ µû¸¥ ´ÜÀ§ ³Ã³­¹æºÎÇÏ Àú°¨ È¿°ú´Â ³Ã¹æÀÇ °æ¿ì 8.6~12.3%, ³­¹æÀÇ °æ¿ì 14.0~15.2%·Î ³ªÅ¸³µÀ¸¸ç, ÀÌ´Â ÇöÇà ¿¡³ÊÁöÀý¾à¼³°è±âÁØÀÇ ´Ü¿­ ¼º´ÉÀÌ Á¦·Î¿¡³ÊÁö °ÇÃ๰¿¡ ±ÙÁ¢ÇÏ´Â ¼öÁØ¿¡ µµ´ÞÇßÀ½À» ÀǹÌÇÑ´Ù.
(6) ´Ü¿­ ±âÁØ °­È­¸¦ ÅëÇÑ ´ÜÀ§ ³Ã³­¹æºÎÇÏ Àú°¨Àº ÀÏÁ¤ ¼öÁØ ÇÑ°è¿¡ À̸¥ °ÍÀ¸·Î º¸ÀÌ¸ç ¹Ì·¡¿¡´Â °í¼º´É âȣ °³¹ß ¹× ¾×ƼºêÇü Â÷¾çÀ» ÅëÇØ ´ÜÀ§ ³Ã³­¹æºÎÇϸ¦ Àú°¨ÇÒ ¼ö ÀÖÀ» °ÍÀ¸·Î ÆǴܵȴÙ. ¶ÇÇÑ Ä§±â ¹× ´©±â¿¡ µû¸¥ ´ÜÀ§ ³Ã³­¹æºÎÇÏ°¡ Å« ¿äÀÎÀÎ ¸¸Å­ °í±â¹Ð¼º È®º¸¸¦ ÅëÇÑ ºÎÇÏ Àú°¨ ¶ÇÇÑ Áß¿äÇÑ ±â¼ú¿ä¼Ò°¡ µÉ °ÍÀ¸·Î º¸ÀδÙ.


º» ¿¬±¸¸¦ ÅëÇØ Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ Àǹ«È­¿¡ µû¶ó °øµ¿ÁÖÅÿ¡¼­ ¿ä±¸µÇ´Â ´ÜÀ§ ³Ã³­¹æºÎÇÏ ¼öÁØÀº ÇöÇà ´ÜÀ§ ³Ã³­¹æºÎÇÏ ±âÁØ°úÀÇ Å« °ÝÂ÷°¡ ÀÖÀ½À» Á¤·®ÀûÀ¸·Î Á¦½ÃÇÏ¿´´Ù. ÀÌ·¯ÇÑ ¿¬±¸ °á°ú¸¦ ÅëÇØ ÇöÇà ´ÜÀ§ ³Ã³­¹æºÎÇÏ ±âÁØÀ» Á¦½ÃÇÏ´Â Çѱ¹Áö¿ª³­¹æ°ø»ç ?¿­»ç¿ë½Ã¼³±âÁØ?°ú »ê¾÷Ç¥ÁØ±Ô°Ý KS C 9306ÀÇ ´ÜÀ§ ³Ã³­¹æºÎÇÏ ±âÁØ °³¼±¿¡ ÁÁÀº ÀÚ·á·Î½á È°¿ëµÉ ¼ö ÀÖ±æ ¹Ù¶ó¸ç, ÃßÈÄ Á¦·Î¿¡³ÊÁö ÁÖÅÃÀ» À§ÇÑ ´ÜÀ§ ³Ã³­¹æ ºÎÇÏ ±âÁØ Á¦Á¤¿¡ ÀÖ¾î ÁÁÀº Âü°íÀÚ·á°¡ µÉ ¼ö ÀÖÀ» °ÍÀ¸·Î »ç·áµÈ´Ù. ´Ù¸¸, ÇÑ °¡Áö ¾Æ½¬¿î Á¡Àº ÇöÇà ¿¡³ÊÁöÀý¾à¼³°è±âÁØ°ú Á¦·Î¿¡³ÊÁö °ÇÃ๰ ÀÎÁõ °¡À̵å¶óÀο¡ µû¸¥ ´ÜÀ§ ³Ã³­¹æºÎÇÏ °á°ú¸¦ µµÃâÇÔ¿¡ ÀÖ¾î ¿­°ü·ùÀ²°ú Á¶¸í¹Ðµµ µÎ °¡Áö¸¦ ¼³°è º¯¼ö·Î ÇÑÁ¤ÇÔ¿¡ µû¶ó ±× ÇÑ°è°¡ Á¸ÀçÇß´Ù. ÇÏ¿© ÃßÈÄ ¿¬±¸¿¡¼­´Â ´Ù¾çÇÑ ¼³°è º¯¼öµéÀ» °´°üÀûÀ¸·Î Á¤·®È­ÇÏ¿© ¹æÀ§º°, ¾ÆÆÄÆ® Ãþ¼ö, â¸éÀûºñ, SHGC, ħ±â ¹× ¿Ü±â¿¡ µû¸¥ ¿µÇâµéµµ »ìÆ캼 ¼ö ÀÖÀ» °ÍÀ¸·Î ÆǴܵȴÙ.
¿ä¾à2 In this study, theoretical reference building model for apartment house was established, and heating and cooling loads per unit were calculated in accordance with the current standard for energy conservation design in buildings and zero-energy building certification guidelines. Subsequently, an analysis was conducted, categorizing the results by region for 17 different cities, by floor area for 3 unit types, and by unit layout for 9 unit types. The analysis also considered heating and cooling load components based on both the current standard for energy conservation design in buildings and zero-energy building certification guidelines. The significant conclusions derived from this analysis can be summarized as follows. According to the current standard for energy conservation design in buildings, it is possible to achieve a reduction of 55.1% to 62.0% in cooling load compared to KS C 9306. For heating, a load reduction of 31.7% to 37.0% is achievable compared to the heat utilization facilities standard of the Korea District Heating Corporation. Application of zero-energy building certification guidelines, in comparison to the current standard for energy conservation design in buildings, results in a cooling load reduction of 8.6% to 12.3% and a heating load reduction of 14.0% to 15.2%. These findings indicate that the insulation performance of current standard for energy conservation design in buildings is approaching the level required for zero-energy buildings. In the future, in order to reduce the energy demand of apartment house in compliance with mandatory zero-energy building certification, it can be concluded that a reduction in heating and cooling load through the mitigation of factors other than insulation will be necessary.
¼ÒÀåó ´ëÇѼ³ºñ°øÇÐȸ
¾ð¾î Çѱ¹¾î
DOI https://doi.org/10.6110/KJACR.2023.35.12.633
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
±¹³» Æнúê°ÇÃ๰ ¼³°è ¹× ½Ã°ø»ç·Ê
À̸íÁÖ - Çѱ¹±×¸°ºôµùÇùÀÇȸ Ãß°èÇмú°­¿¬È¸ ³í¹®Áý : (200911)
È£ÅÚ, º´¿ø, ¾÷¹«¿ë °Ç¹°ÀÇ ¿¡³ÊÁö ºÎÇÏ Æ¯¼º ºñ±³
¹ÚÈ­Ãá(Hwa-Choon Park) ; Á¤¸ð(Mo Chung) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.21 No.10 (200910)
½Ç¹«ÀÚ¸¦ À§ÇÑ º´¿ø¼³ºñÀÇ ÀÌÇØ
¹ÚÀºµ¿ ; ±èÈ¿ÁØ - ´ëÇѼ³ºñ°øÇÐȸ ÇÏ°èÇмú¹ßǥȸ ³í¹®Áý : (201206)
Á¦·Î¿¡³ÊÁö°ÇÃ๰(ZEB/H) ¼³ºñ½Ã½ºÅÛ ±â¼ú·Îµå¸Ê ¼ö¸³À» À§ÇÑ ¼±Ç࿬±¸ ºÐ¼®: ÃÖ±Ù 10³â ÇØ¿Ü¿¬±¸»ç·Ê
Àå½Â¹Î(Seungmin Jang) ; Àå¾Æ¹Î(Ahmin Jang) ; µµ¼º·Ï(Sung Lok Do) ; Á¶Áø±Õ(Jinkyun Cho) ; ±èö(Chul Kim) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.35 No.09 (202309)
°øµ¿ÁÖÅà °á·Î ÇÏÀÚ »ç·Ê¸¦ ÅëÇÑ °³¼±¹æ¾È µµÃâ
¿À¼¼¹Î(Se Min Oh) ; ¹Ú¼±È¿(Sun Hyo Park) ; Á¤±¤¼·(Kwang Sub Joung) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.29 No.02 (201702)
[ƯÁý] ¹æ¼ö°ø»çÀÇ Á¾·ù¿Í ½Ã°ø±â¼úÀÇ ÀÌÇØ
¾È»ó·Î ; °û±Ô¼º ; ÃÖ¼º¹Î ; ¿À»ó±Ù - Çѱ¹°ÇÃà½Ã°øÇÐȸÁö : v.10 n.4(Åë±Ç Á¦42È£) (201008)
[ƯÁý¿ø°í] µ¥ÀÌÅͼ¾ÅÍ °ÇÃà°èȹ
¼ÕÁö¼ö - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : Vol.34 No.03 (201703)
[ƯÁý¿ø°í] À¯·®Á¶Àý ½Ã½ºÅÛÀÇ Àû¿ë»ç·Ê
ÀÌâ±Ù ; ¹Ú±â¹ü - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.26 n.06 (200906)
Á¦·Î¿¡³ÊÁöºôµù ÀÎÁõÀ¸·Î ÀÎÇÑ ¾ÆÆÄÆ® ¿­¿ø ¼±Á¤ ¿µÇ⠺м®¿¡ °üÇÑ ¿¬±¸
ÃÖ½½°Ç(Sul Geon Choi); ¹ÚµÎ¿ë(Doo Yong Park) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.33 No.6 (202106)