| ³í¹®¸í |
±â´É¼öÇà¼öÁØÀÇ ÁöÁø¿¡ ´ëÇÑ °íÃþ º®½Ä°øµ¿ÁÖÅà ¿ÜºÎ º®Ã¼¿Í º¸ÀÇ ¼Õ»óÁ¤µµºÐ¼® / Damage Analysis of Exterior Walls and Beams of High-Rise Wall-type Apartment Buildings Under Operational Performance Level Earthquakes |
| ÀúÀÚ¸í |
È«³ª·¡(Hong, Na-Rae) ; ±è¼ºÇö(Kim, Sung-Hyun) ; ¹Ú¿øÀÏ(Park, Won-Il) ; °¼ö¹Î(Kang, Su-Min) ; ÃÖ°æ±Ô(Choi, Kyoung-Kyu) ; ¹ÚÈ«±Ù(Park, Hong-Gun) |
| ¼ö·Ï»çÇ× |
´ëÇѰÇÃàÇÐȸ³í¹®Áý, Vol.38 No.11 (2022-11) |
| ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(327) ÃÑÆäÀÌÁö(12) |
| ÁÖÁ¦¾î |
°íÃþ°øµ¿ÁÖÅà ¿Üº® ¹× ¼öÆò¿ä¼Ò; ºñ±¸Á¶¿ä¼Ò ±Õ¿; ±â´É¼öÇà ¼º´É¼öÁØ; ¼±Çü ½Ã°£ÀÌ·ÂÇØ¼®; ¼º´É±â¹Ý³»Áø¼³°è ; Exterior RC walls and horizontal components; Cracks of non-structural members; Operational performance level; Linear time history analysis; Performance based seismic design |
| ¿ä¾à1 |
¼º´É±â¹Ý³»Áø¼³°è¿¡¼ °íÃþ °øµ¿ÁÖÅà ¿ÜºÎ º®Ã¼ ¹× ¼öÆò ¿ä¼Ò¸¦ ºñ±¸Á¶Àç·Î Ãë±ÞÇÏ¿© ¼³°èÇÒ °æ¿ì, ÀÛÀº ÁöÁø¿¡µµ ±Õ¿ ¹× ¼Õ»óÀÌ ¹ß»ýÇÏ¿© ¾ÆÆÄÆ® °ÅÁÖÀÚµéÀÇ ºÒ¾È°¨À» Á¶¼ºÇÒ °¡´É¼ºÀÌ ÀÖ´Ù. µû¶ó¼ º» ¿¬±¸¿¡¼´Â ¼±Çü ½Ã°£ÀÌ·Â ÇØ¼®À» ¼öÇàÇÏ¿© °íÃþ °øµ¿ÁÖÅÃÀÇ ºñ±¸Á¶ ¿Üº® ¹× ¼öÆò¿ä¼ÒÀÇ ±Õ¿¾ç»óÀ» ºÐ¼®ÇÏ°í ³»Áø Ãë¾àºÎÀ縦 ºÐ·ùÇÏ¿´´Ù. ¼±Çü ½Ã°£ÀÌ·ÂÇØ¼® ½Ã ÁöÁøÇÏÁß ¸ðµ¨¸µÀº ±â´É¼öÇà ¼öÁØÀÇ ÀÛÀº ÁöÁøÇÏÁßÀ» »ç¿ëÇÏ¿´´Ù. ¶ÇÇÑ, ¼³°è ½Ã ºñ±¸Á¶Àç·Î Ãë±ÞµÈ ¿Üº® ¹× ¼öÆò¿ä¼Ò¸¦ ÇØ¼®¸ðµ¨¿¡ ¹Ý¿µÇÏ¿´´Ù. ÇØ¼®°á°ú, º®Ã¼ÀÇ °æ¿ì ÀÌÇüº®Ã¼¿Í ºñ±¸Á¶Àç·Î ¼³°èµÈ º®Ã¼°¡ Ãë¾àºÎÀç·Î ÆÇº°µÇ¾ú´Ù. ¶ÇÇÑ, ¼öÆò¿ä¼ÒÀÇ °æ¿ì Å« °³±¸ºÎ »óÇϺÎÀÇ ¼öÆò¿ä¼Ò¿Í ÄÚ¾î¿Í ÀÎÁ¢ÇÑ ¼öÆò¿ä¼Ò°¡ Ãë¾àºÎÀç·Î ÆÇº°µÇ¾ú´Ù. |
| ¿ä¾à2 |
In a performance based seismic design (PBD) of a high-rise apartment building, the exterior RC walls are designed as non-structural members; severe cracks and damages could occur even from a small earthquake which is a cause for anxiety for residents. In this study, vulnerable members to seismic load were classified and the occurrence of cracking in the exterior walls regarded as non-structural members of high-rise apartments were investigated by a linear time history analysis. In the linear time history analysis, a small seismic load of the operational performance level was used. A numerical analysis model was applied to the exterior walls and horizontal components regarded as non-structural members. The analysis results showed that the non-planar walls and the non-structured walls were classified as vulnerable members to seismic loads. Furthermore, the horizontal components located in the upper and lower parts of the large opening and the connecting beams adjacent to the core walls were also classified as vulnerable members to seismic load. |