°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

´ëÇѰÇÃàÇÐȸ|³í¹®Áý 2022³â 10¿ù

³í¹®¸í °øµ¿ÁÖÅÃÀÇ ½Ã°øÇ°Áú °ü¸® ¹× Çâ»óÀ» À§ÇÑ ¡®Ç°ÁúÁ¡°Ë¡¯Á¦µµ ½ÇÈ¿¼º Á¦°í¹æ¾È / A Study on the Effectiveness of the ¡®Quality Inspection¡¯ System for Construction Quality Improvement and Control of Apartment Buildings
ÀúÀÚ¸í ±èÇüÁØ(Kim, Hyoung-Jun) ; ÀåÇö½Â(Jang, Hyoun-Seung)½Äº°ÀúÀÚ ; ¿ÁÁ¾È£(Ock, Jong-Ho)
¹ßÇà»ç ´ëÇѰÇÃàÇÐȸ
¼ö·Ï»çÇ× ´ëÇѰÇÃàÇÐȸ³í¹®Áý, Vol.38 No.10 (2022-10)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(301) ÃÑÆäÀÌÁö(11)
ISSN 2733-6247
ÁÖÁ¦ºÐ·ù ½Ã°ø(Àû»ê)
ÁÖÁ¦¾î °øµ¿ÁÖÅÃ; ½Ã°øÇ°Áú; ǰÁúÁ¡°Ë(°Ë¼ö)Á¦µµ; Á¦µµ°³¼±; µ¨ÆÄÀ̱â¹ý; IPA ±â¹ý ; Apartment house; Construction Quality; Quality Inspection System; System Improvement; Delphi Technique; Importance- Performance Analysis
¿ä¾à1 ǰÁú°Ë¼öÁ¦µµ´Â 2006³â °æ±âµµ¸¦ Áß½ÉÀ¸·Î '°¨¸®¡¤»ç¿ë°Ë»ç' Á¦µµ¸¦ º¸¿ÏÇϱâ À§ÇØ µµÀÔµÈ ÀÌÈĺÎÅÍ ÁֹεéÀÇ ±àÁ¤ÀûÀÎ ¹ÝÀÀÀ¸·Î Àü±¹ Áö¹æÀÚÄ¡´Üü¿¡ º¸±Þ¡¤¿î¿µµÇ°í ÀÖ´Ù. ±×·¯´Ù 2020³â 1¿ù 23ÀÏ ÁÖÅùý Á¦48Á¶ÀÇ2°¡ ½Å¼³µÇ¾î ±âÁ¸¿¡ Á¦±âµÇ¾ú´ø ¹®Á¦Á¡À» °³¼±ÇÏ¿´´Ù. µû¶ó¼­ º» ³í¹®Àº Áö¹æÀÚÄ¡´Üü Á¶·Ê¿Í ÁÖÅùý °£ÀÇ 'ǰÁú°Ë¼ö' Á¦µµ¸¦ ºñ±³ ºÐ¼®Çϰí, Àü¹®ÀûÀÎ µ¨ÆÄÀÌ ¹æ½ÄÀ¸·Î ¼³¹®ÁöÇ¥¸¦ ¼±Á¤Çϰí, IPA ºÐ¼®À» ÅëÇØ ¼³¹®Á¶»ç °á°ú¸¦ »ìÆìº¸°íÀÚ ÇÏ¿´´Ù.
¿ä¾à2 The quality inspection system of local governments, which was introduced in 2006, was newly established in the Housing Act in 2021 and
implemented nationwide. Therefore, this paper compared and analyzed the previous quality inspection system and the subsequent quality
inspection system, and created an expert Delphi-style questionnaire. Finally, it was intended to present a plan to improve the quality
inspection system by analyzing the satisfaction, expected effects, and side effects of the quality inspection system through IPA. It is
summarized in three ways: First, in the visual-centered inspection method, it is necessary to introduce equipment inspection and destruction
inspection for necessary construction. Second, it should be operated as a complementary role with the supervision and use inspection system.
Third, it is also necessary to check the background construction between the structure and the finishing material.
¼ÒÀåó ´ëÇѰÇÃàÇÐȸ
¾ð¾î Çѱ¹¾î
DOI https://doi.org/10.5659/JAIK.2022.38.10.301
ºÐ¼®¼­Áö
°Ç¼³°ü¸® > ÇÁ·ÎÁ§Æ®°ü¸® > ǰÁú°ü¸®

¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[½Ã·Ð] 4Â÷ »ê¾÷Çõ¸í ½Ã´ë, °ÇÃàÀÇ ´ëÀÀ
À̸í½Ä(Lee, Myung-Sik) - °ÇÃà(´ëÇѰÇÃàÇÐȸÁö) : Vol.61 No.05 (201705)
Ȱµ¿±âÁØ¿ø°¡°è»ê¹ý(Actvitiy-Based Costing)¿¡ ÀÇÇÑ ¸ðµâ·¯ °ÇÃ๰ °øÀåÁ¦ÀÛ´Ü°è °£Á¢ºñ »êÁ¤ ¹æ¾È
ÀÌÁ¤ÈÆ(Lee, JeongHoon) ; ¹Ú¹®¼­(Park, Moonseo) ; ÀÌÇö¼ö(Lee, Hyun-Soo) ; À̱¤Ç¥(Lee, Kwang-Pyo) ; ÇöÈ£»ó(Hyun, Hosang) - Çѱ¹°Ç¼³°ü¸®ÇÐȸ ³í¹®Áý : Vol.16 No.4 (201507)
[ƯÁý] ¹æ¼ö°ø»çÀÇ Á¾·ù¿Í ½Ã°ø±â¼úÀÇ ÀÌÇØ
¾È»ó·Î ; °û±Ô¼º ; ÃÖ¼º¹Î ; ¿À»ó±Ù - Çѱ¹°ÇÃà½Ã°øÇÐȸÁö : v.10 n.4(Åë±Ç Á¦42È£) (201008)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
[±â¼úÁ¤º¸] È븷À̰¡½Ã¼³ÀÇ Á¾·ù ¹× ÃֽŰø¹ý ¼Ò°³
À±¼ºÇÊ - °Ç¼³±â¼ú¤Ó½Ö¿ë : 2010. °¡À»È£(v.56) (201009)
°øµ¿ÁÖÅà ÄÜÅ©¸®Æ® ±Õ¿­ÀÇ ¹Ì°ü»ó ÇÏÀÚ ÆÇÁ¤±âÁØ¿¡ °üÇÑ ¿¬±¸
Ç㼺ȸ(Hur Seong-Hoe) ; ±è¿µ¾Ö(Kim Young-Ae) ; Ȳ¹®È¯(Hwang Moon-Hwan) ; ±è¿ë¼ö(Kim Yong-Su) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý ±¸Á¶°è : v.26 n.04 (201004)
°Ç¼³±â¾÷ ¿ø°¡°ü¸® ÆÐÅÏÀÇ ÇöȲ ¹× º¯È­ ºÐ¼®
Á¤¿µ¼ö(Jung, Youngsoo) ; ÁÖ¹ÌÈñ(Joo, Mihee) - Çѱ¹°Ç¼³°ü¸®ÇÐȸ ³í¹®Áý : Vol.12 No.4 (201107)
[¿¬±¸³í¹®-°ÇÃࡤÁÖÅÃ] °øµ¿ÁÖÅà ÁöÇÏÁÖÂ÷Àå °á·Î ¹æÁö ¹æ¾È
È«¼®Áø ; ¼º±âö ; ±èÁöÇö - ´ë¿ì°Ç¼³±â¼ú : Åë±Ç Á¦32È£ (201008)
ÅØ½ºÆ® ¸¶ÀÌ´× ±â¹ýÀ» ÀÌ¿ëÇÑ °øµ¿ÁÖÅà ÇÏÀÚÀÇ À¯Áö°ü¸® ¿ä¼Ò ºÐ¼®
¹æÈ«¼ø(Bang, Hong-Soon) ; ÇãÇѰá(Heo, Han-Kyul) ; ±è¿Á±Ô(Kim, Ok-kyue) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý : Vol.38 No.9 (202209)
°Ç¼³»ç¿Í ÀÔÁÖ¹ÎÀÇ °øµ¿ÁÖÅà ÇÏÀÚºÐÀï ÀïÁ¡ ¹× °³¼± ¹æ¾È
¹æÈ«¼ø(Bang, Hong-Soon) ; ±è¿Á±Ô(Kim, Ok-Kyue) - Çѱ¹°ÇÃà½Ã°øÇÐȸ ³í¹®Áý : Vol.22 No.1 (202202)