°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

´ëÇÑ°ÇÃàÇÐȸ|³í¹®Áý 2021³â 11¿ù

³í¹®¸í Äڷγª½Ã´ë¿¡ ´ëÀÀÇÏ´Â ¿Á¿Ü°ø°£À¸·Î¼­ ±¹³»¿Ü ¹ßÄÚ´Ï ºñ±³ ¿¬±¸ / Case Studies and Implications of Residential Building's Balcony Standards on COVID-19 Era
ÀúÀÚ¸í ³²¼º¿ì ; Á¶»ó±Ô½Äº°ÀúÀÚ
¹ßÇà»ç ´ëÇÑ°ÇÃàÇÐȸ
¼ö·Ï»çÇ× ´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý, Vol.37 No.11 (2021-11)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(121) ÃÑÆäÀÌÁö(10)
ISSN 2733-6247
ÁÖÁ¦ºÐ·ù ÀÌ·Ð / °èȹ¹×¼³°è
ÁÖÁ¦¾î Äڷγª-19; ÁÖ°Å¿ë °ÇÃ๰; °³¹æÇü ¹ßÄÚ´Ï; ¼³Ä¡ ±âÁØ; Á¦µµ °³¼± ; COVID-19; Residential Building; Open Balcony; Standards of Establishment; System Improvement
¿ä¾à1 º» ¿¬±¸¿¡¼­´Â ±¹³»¿Í ÇØ¿Ü ÁÖ¿ä±¹¿¡¼­ »çÀû ¿Á¿Ü°ø°£À¸·Î ±â´ÉÇÒ ¼ö ÀÖ´Â °³¹æÇü ¹ßÄÚ´ÏÀÇ ±âÁØ°ú »ç·Ê¸¦ ºñ±³ ºÐ¼®ÇÏ¿´´Ù. ±× °á°ú ù°, ±¹³»¿¡¼­´Â µµ½Ã°æ°ü¿¡ ´ëÇÑ Æ¯È­ ¹æ¾ÈÀÇ Çϳª·Î °³¹æÇü ¹ßÄڴϸ¦ ¼³Ä¡ÇÏ´Â ¹æ½ÄÀ¸·Î ¿î¿µµÇ´Â ¹Ý¸é, ÇØ¿Ü¿¡¼­´Â ÄèÀûÇÑ ÁÖ°Åȯ°æ µî ¹ßÄÚ´Ï º»¿¬ÀÇ ±â´ÉÀ» ¼öÇàÇÏ°í, ´ëÇǸ¦ À§ÇÑ °ø°£À¸·Î ¿î¿µµÇ°í ÀÖ´Ù´Â Á¡°ú µÑ°, ±¹³»¿¡¼­´Â ¹Ù´Ú¸éÀûÀ» Æ÷ÇÔÇÏÁö ¾Ê´Â ±ÔÁ¤À¸·Î ¹ßÄÚ´Ï ¼³Ä¡ ±Ô¸ð°¡ Á¦ÇѵǾî ÀÖ´Â ¹Ý¸é, ÇØ¿Ü¿¡¼­´Â µ¹ÃâµÈ Æø, ±æÀÌ µî °³¹æÇü ¹ßÄÚ´ÏÀÇ ±¸Ã¼Àû ±âÁØÀ» Á¦½ÃÇÏ°í ÀÖÀ½À» µµÃâÇÏ¿´´Ù.
¿ä¾à2 This study seeks to overcome COVID-19 and re-examine the balcony as a new, differentiated residential space that requires change in the
coming post-corona era. In this study, theoretical considerations on the concept and definition of the balcony and the original purpose and
function are reviewed. This study compares and analyzes standards and cases for open balconies that can function as private outdoor spaces
in Korea and major foreign countries. The key results of this study are as follows. First, while in Korea, the system is operated to install an
open balcony as one of the specialized measures in terms of urban landscape, overseas, the system is designed to perform the original
function of the balcony, such as a comfortable living environment and space for evacuation that it is operating. Second, while in Korea, the
scale of installation of balconies is limited through regulations that exclude the inclusion of floor area, in overseas countries, specific
standards for the shape of open balconies, such as the protruding width and length, are prepared. As a follow-up to this study, institutional
research should be conducted to specify the standard for the shape and size of external balconies, and safety and performance standards.
¼ÒÀåó ´ëÇÑ°ÇÃàÇÐȸ
¾ð¾î Çѱ¹¾î
DOI https://doi.org/10.5659/JAIK.2021.37.11.121
ºÐ¼®¼­Áö
°ÇÃà°èȹ ¹× ¼³°è > ÁÖ°Å°ÇÃà °èȹ > ÁÖ°Å·Ð ÀϹÝ

¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
Æ÷½ºÆ® Äڷγª ½Ã´ë¿¡ ´ëÇÑ °ÇÃà °èȹÀû ´ëÀÀ ¹æ¾È ¿¬±¸
±è¹Î¼®(Kim, Minseok) - ´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý : Vol.37 No.02 (202102)
[½Ã·Ð] 4Â÷ »ê¾÷Çõ¸í ½Ã´ë, °ÇÃàÀÇ ´ëÀÀ
À̸í½Ä(Lee, Myung-Sik) - °ÇÃà(´ëÇÑ°ÇÃàÇÐȸÁö) : Vol.61 No.05 (201705)
Æ÷½ºÆ® Äڷγª¿¡ ´ëÀÀÇÑ ÁÖ°Å¿ë °ÇÃ๰ °³¹æÇü ¹ßÄÚ´Ï Á¶¼º ¹æ¾È
Á¶»ó±Ô;±è¿µÇö;³²¼º¿ì;±è½Å¼º - AURI BRIEF : No. 225 (202101)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
Æ÷½ºÆ® Äڷγª¿¡ ´ëÀÀÇÑ ÁÖ°Å¿ë °ÇÃ๰ ¿ÜºÎ ¹ßÄÚ´Ï È°¼ºÈ­ ¹æ¾È
Á¶»ó±Ô ; ±è¿µÇö ; ³²¼º¿ì ; ±è½Å¼º - ¿¬±¸º¸°í¼­(Á¤Ã¥) : 2020 No.06 (202012)
·½ ÄðÇϽº¿Í Ä«Áî¿ä ¼¼Áö¸¶ °ÇÃà¿¡¼­ ³ªÅ¸³ª´Â ÇÁ·Î±×·¥ÀÇ Á¶Á÷°ú °ø°£±¸¼º ¹æ¹ýÀÇ ºñ±³ºÐ¼®
±Ç°æ¹Î ; ±èÁ¾Áø - Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ ³í¹®Áý : v.16 n.6(Åë±Ç 65È£) (200712)
½Ã·Ð: Äڷγª ÀÌÈÄ, °ÇÃà°ú µµ½Ã°ø°£ÀÇ º¯È­¸¦ »ý°¢ÇÏ´Ù
¹Ú¼ÒÇö - °ÇÃà°ú µµ½Ã°ø°£ : Vol.38 (202006)
[ƯÁý] Äڷγª19 µî °¨¿°°ú Àü¿°, ¿¹¹æ°ú Ä¡·áÀ» À§ÇÑ °ÇÃàÀû ´ëÀÀ
À̸í½Ä(Lee, Myung-Sik) - °ÇÃà(´ëÇÑ°ÇÃàÇÐȸÁö) : Vol.64 No.06 (202006)
°ÇÃࡤµµ½Ã°ø°£ÀÇ Çö´ëÀû °ø°ø¼º¿¡ °üÇÑ ±âÃÊ ¿¬±¸
¿°Ã¶È£ ; ½É°æ¹Ì ; Á¶Áعè - ¿¬±¸º¸°í¼­(±âº») : 2008 n.8 (200902)
»ç¶÷ Á᫐ °¡·Î Á¶¼ºÀ» À§ÇÑ µµ½Ã¼³°è ¿¬±¸
ÀÓÀ¯°æ(Lim, Yookyoung) ; ¼ºÀº¿µ(Seong, Eunyoung) ; ÀÓ°­·û(Lim, Kang Ryoon) - ¿¬±¸º¸°í¼­(±âº») : 2015 No.06 (201510)