³í¹®¸í ¿Á¿Ü¼ÒÈ­Àü ¾Ð·Â¼Õ½Ç½ÃÇè ¹× ±âÁØ µµÀÔ¿¡ °üÇÑ ¿¬±¸ / A study on the adoption of standard and testing of outdoor fire hydrant pressure loss test
ÀúÀÚ¸í ÇÑ¿ëÅà ; ¹æÃ¢ÈÆ
¹ßÇà»ç Çѱ¹ÁÖ°Åȯ°æÇÐȸ
¼ö·Ï»çÇ× Çѱ¹ÁÖ°Åȯ°æÇÐȸ ³í¹®Áý <ÁÖ°Åȯ°æ>, Vol.19 No.1(Åë±Ç Á¦51È£) (2021-03)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(215) ÃÑÆäÀÌÁö(10)
ISSN 17380316
ÁÖÁ¦ºÐ·ù µµ½Ã
ÁÖÁ¦¾î ¿Á¿Ü¼ÒÈ­Àü; ¾Ð·Â¼Õ½Ç; È­Àç¾ÈÀü±âÁØ ; Outdoor fire hydrant; Pressure loss; NFSC
¿ä¾à1 ¿Á¿Ü¼ÒÈ­ÀüÀº È­Àç¹ß»ý ½Ã ¼Ò¹æÈ£½º¸¦ ÀÌ¿ëÇÏ¿© Á÷Á¢ È­À縦 Áø¾ÐÇÒ ¼ö ÀÖµµ·Ï ÀûÁ¤ ¾Ð·Â ¹× À¯·®ÀÇ ¼ÒÈ­¿ë¼ö¸¦ Á¦°øÇϰųª ¼Ò¹æÀÚµ¿Â÷¿¡ ¼ÒÈ­¿ë¼ö¸¦ °ø±ÞÇØ ÁÖ´Â ¿ªÇÒÀ» ÇÑ´Ù. º» ¿¬±¸¿¡¼­´Â ±¹³»¿¡¼­ Á¦Á¶ ÆÇ¸ÅµÇ´Â 4°³»çÀÇ ¿Á¿Ü¼ÒÈ­Àü¿¡ ´ëÇÑ ¾Ð·Â¼Õ½Ç ÃøÁ¤ ½ÇÇèÀ» ÅëÇÑ ¾Ð·Â¼Õ½Ç °ªÀ» ºñ±³ ºÐ¼®ÇÏ¿´À¸¸ç, ¼±Áø ÇØ¿Ü±âÁØÀÎ UL ¹× FM µî¿¡¼­ Á¤Çϰí ÀÖ´Â ¾Ð·Â ¼Õ½Ç °ªÀ» ºñ±³ÇÏ¿© ´ÙÀ½°ú °°Àº °á·ÐÀ» ¾òÀ» ¼ö ÀÖ¾ú´Ù. ÇöÀç ±¹³»ÀÇ ¿Á¿Ü¼ÒÈ­Àü¼³ºñÀÇ ¼³°è¿¡´Â Áö»ó½Ä ¿Á¿Ü¼ÒÈ­Àü¿¡ ´ëÇÑ ¾Ð·Â¼Õ½Ç °ªÀÌ ÀüÇô ¹Ý¿µµÇÁö ¾Ê°Å³ª, ½ÇÇè°á°ú ¼±Áø ÇØ¿Ü ±Ô°Ý¿¡¼­ Á¤ÇÑ Æ¯Á¤ À¯·® °ª¿¡¼­ÀÇ 13.7 kPaÀÇ ¾Ð·Â¼Õ½ÇÀÇ ±âÁØÀ» ÃʰúÇÏ´Â ¾Ð·Â¼Õ½Ç °á°ú¸¦ ¾òÀ» ¼ö ÀÖ¾ú´Ù. Çü½Ä½ÂÀÎ ¹× Á¦Ç°°Ë»çÀÇ ±â¼ú±âÁØÀ» °í½Ã¡¤¿î¿µÇÏ´Â ¼Ò¹æÃ»°ú Çѱ¹¼Ò¹æ»ê¾÷±â¼ú¿øÀº ¡¸¼ÒÈ­ÀüÀÇ Çü½Ä½ÂÀÎ ¹× Á¦Ç°°Ë»çÀÇ ±â¼ú±âÁØ¡¹¿¡ Áö»ó½Ä ¿Á¿Ü¼ÒÈ­Àü¿¡ ´ëÇÑ ¾Ð·Â¼Õ½Ç ±âÁØÀ» Á¶¼ÓÈ÷ µµÀÔÇÏ¿©¾ß ÇÑ´Ù.
¿ä¾à2 The outdoor fire hydrant system is one of the fire extinguishing systems that are operated and managed on the basis of the separate facility standards in the national fire safety standards. The most representative product among the outdoor fire hydrant systems is the ground type outdoor fire hydrant system. Therefore, in the domestic market, the outdoor fire hydrant is designated as a type approval subject to the laws and regulations, and only the products that meet the standards are installed and operated. However, the research on outdoor fire hydrants is very poor compared to other fire extinguishing products. Especially, although pressure loss is a very important characteristic and factor in outdoor fire hydrant. Even the people in public fire hydrants and producers do not know the loss of pressure on products. In fact, the design of the outdoor fire hydrant system does not reflect the pressure loss value for the ground type outdoor fire hydrant, or reflects the minimum pressure loss value defined by the UL standard at once. So, in this study, the pressure loss values of the four representative products manufactured and produced in Korea were measured and compared with the measured pressure loss values. The pressure loss values in domestic outdoor fire hydrant The standards UL, FM and the reference values were compared. As a result of this, it is possible to introduce the standard value of pressure loss in advanced domestic and foreign fire hydrants as soon as possible and to be able to effectively cope with the actual performance and response in the early and mid-term fire, Suggest that. In addition, manufacturers of outdoor fire hydrant are expected to secure accurate pressure loss data in order to secure competitiveness for their products.