´ëÇѼ³ºñ°øÇÐȸ|¼³ºñ°øÇÐ³í¹®Áý 2020³â 5¿ù

³í¹®¸í µ¥ÀÌÅͼ¾ÅÍ °øÁ¶¡¤³Ã°¢½Ã½ºÅÛ ¹æ½Ä±¸ºÐ ¹× ÀûÇÕ¼º ¼º´É½ÃÇè ¹æ¹ý/±âÁØ¿¡ ´ëÇÑ ¿¬±¸ / A Study on Performance Standard and Test Method of CRAC/H(Computer Room Air Conditioning/Handling) Units for Data Centers
ÀúÀÚ¸í Á¶Áø±Õ½Äº°ÀúÀÚ ; ±è¼±Á¤ ; Á¤¿ë´ë ; ¹Úº´¿ë½Äº°ÀúÀÚ
¹ßÇà»ç ´ëÇѼ³ºñ°øÇÐȸ
¼ö·Ï»çÇ× ¼³ºñ°øÇÐ³í¹®Áý, Vol.32 No.5 (2020-05)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(235) ÃÑÆäÀÌÁö(14)
ISSN 1229-6422
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î µ¥ÀÌÅͼ¾ÅÍ; °øÁ¶?³Ã°¢½Ã½ºÅÛ; µ¥ÀÌÅͼ¾ÅÍ ³Ã°¢±â±â; ¼º´É½ÃÇè; IT±â±â ¿î¿µÈ¯°æ ; Data center; Cooling system; CRAC/H units; Performance testing; IT environment
¿ä¾à1 µ¥ÀÌÅͼ¾ÅÍ ¿î¿µ?¼­ºñ½º Áß½ÉÀÇ ±¹³»½ÃÀå Æ¯¼º ¹× ÇØ¿Ü ±â¼ú°úÀÇ °ÝÂ÷¿¡ µû¸¥ »õ·Î¿î µ¥ÀÌÅͼ¾ÅÍ °ü·Ã ITȯ°æ Áö¼Ó°¡´É ±â¼úÀ» È®º¸Çϱâ À§Çؼ­´Â µ¥ÀÌÅͼ¾ÅÍ È¯°æ¿¡ ¸Â´Â ³Ã°¢½Ã½ºÅÛÀÇ ¼º´É±âÁØÀÌ ¸íÈ®ÇÏ°Ô Á¦½ÃµÇ¾î¾ß ÇÑ´Ù. ½Å»ê¾÷ µ¿·ÂÀÎ IT±â¼úÀÇ ±¸ÇöÀ» À§ÇÑ Áß¿äÇÑ µ¥ÀÌÅͼ¾ÅÍÀÇ »óÈ£ ¿¬°èµÈ Á¾ÇÕÀûÀÎ ³Ã°¢ ¼Ö·ç¼ÇÀÇ ¼º´ÉÆò°¡¿Í ½ÃÇè±âÁØ °³¹ßÀÌ ¿ä±¸µÇ°í ÀÖ´Ù. º» ¿¬±¸´Â Àü¿ë µ¥ÀÌÅͼ¾ÅÍ ³Ã¹æ±â±âÀÎ CRAC/H À¯´ÖÀÇ ¼º´É Æò°¡, ¿¡³ÊÁöÈ¿À² µî ½ÃÇèÆò°¡¸¦ À§ÇÑ Ã¼°èÀûÀÎ °øÁ¶?³Ã°¢½Ã½ºÅÛ À¯ÇüºÐ·ù, ±¹?³»¿Ü Ç¥ÁØ ¹× ½ÃÇè¹æ¹ýÀ» ºÐ¼®ÇÏ¿© ½ÇÁúÀûÀÎ µ¥ÀÌÅͼ¾ÅÍ ITȯ°æÀ¯Áö¿¡ ºÎÇÕÇÑ ½ÃÇè±âÁØ ¹× ¹æ¹ýÀ» Á¦¾ÈÇÏ¿´´Ù. ±× °á°ú¸¦ Á¤¸®ÇÏ¸é ´ÙÀ½°ú °°´Ù.
(1) µ¥ÀÌÅͼ¾ÅÍÀÇ ÀûÁ¤ ITȯ°æÀ» À¯ÁöÇϰí ITÀåºñ¿¡¼­ ¹ß»ýÇÏ´Â ¿­-¿¡³ÊÁö¸¦ ½Ç¿Ü·Î Àü´ÞÇÏ´Â ³Ã°¢¹æ½ÄÀº ¨ç°ø·©½Ä, ¨è¼ö³Ã½Ä, ¨é±Û¸®ÄݽÄÀ» »ç¿ëÇÏ´Â CRAC À¯´Ö°ú, Áß¾Ó¿­¿ø¿¡¼­ »ý»êµÈ ³Ã¼ö¸¦ ÀÌ¿ëÇÏ´Â ¨êÁ߾ӳüö½Ä CRAH À¯´ÖÀÇ 4°¡Áö ¹æ½ÄÀ¸·Î ±¸ºÐµÇ°í °¡Àå º¸ÆíÀûÀ¸·Î Àû¿ëµÇ´Â ¹æ½ÄÀÌ´Ù.
(2) µ¥ÀÌÅͼ¾ÅÍ °øÁ¶(°ø±âºÐ¹è)¹æ½ÄÀº IT¼­¹ö·ë Àüü¸¦ Á¦¾îÇÏ´Â ¨ç°ø´Ü´ÜÀ§ °øÁ¶¹æ½Ä, ·¢-¼­¹ö°¡ ¹è¿­µÈ ÀϺÎÀÇ ±¸¿ªÀ» ´ã´çÇÏ´Â ¨è±¸¿ª´ÜÀ§ °øÁ¶¹æ½Ä, ¸¶Áö¸·À¸·Î °³º° ·¢-¼­¹ö¿¡ ´ëÀÀÇÏ´Â ¨éITÀåºñ´ÜÀ§ °øÁ¶¹æ½ÄÀÇ 3°¡Áö ¹æ½ÄÀ¸·Î ±¸ºÐµÇ°í, ITÀåºñÀÇ ÁýÀûµµ°¡ ³ô¾ÆÁö¸é¼­ ±¸¿ª´ÜÀ§ ¹× ITÀåºñ´ÜÀ§ °øÁ¶¹æ½ÄÀ¸·Î ÀüȯµÇ°í ÀÖ´Ù.
(3) CRAC/H À¯´ÖÀÇ À¯ÇüÀº ¼³Ä¡À§Ä¡¿¡ µû¶ó ¨ç»óÄ¡Çü°ú ¨èõÁ¤ÇüÀ¸·Î ±¸ºÐµÇ°í ´Ù½Ã ±Þ±â(SA) ¹× ȯ±â(RA)¿¡ µû¶ó¼­ »óÇâ½Ä, ÇÏÇâ½Ä, ¼öÆò½ÄÀ¸·Î ºÐ·ùµÈ´Ù. ´õ ¼¼ºÎÀûÀ¸·Î´Â ´öÆ®Çü°ú ¹«´öÆ®ÇüÀ¸·Î ³ª´¶´Ù.
(4) ±¹³»ÀÇ °øÁ¶?³Ã°¢½Ã½ºÅÛ ¼º´ÉÆò°¡ ±â¼úÇ¥ÁØÀº ´öÆ®¾ø´Â ¿¡¾îÄÁ°ú ¿­ÆßÇÁ(KS B ISO 5151), ¿¡¾îÄÁµð¼Å³Ê(KS C 9306) ¹× Ç׿ÂÇ×½À±â(SPS-KARSE B 0001-164) µî À¯»ç ǰ¸ñÀÌ ÀÖÀ¸³ª, ITȯ°æ ¹× ¿î¿µÆ¯¼ºÀ» ¹Ý¿µÇÑ µ¥ÀÌÅͼ¾ÅÍ CRAC/H À¯´Ö¿¡ ºÎÇÕÇÏ´Â ½ÃÇè¹æ¹ý ¹× ±âÁØÀº ¾ÆÁ÷±îÁö´Â ¾ø´Ù.
(5) ÇØ¿Ü´Â ANSI/ASHRAE Standard 127°ú AHRI Standard 1361 µî ITȯ°æÀ» °í·ÁÇÑ °øÁ¶?³Ã°¢ ¹æ½ÄÀÇ ±¸ºÐ ¹× ¸ðµç CRAC/H À¯´Ö À¯ÇüÀ» Æ÷ÇÔÇÏ´Â ±â¼úÇ¥ÁØÀÌ ÀÖ´Ù.
(6) ±¹¿ÜÀÇ µ¥ÀÌÅͼ¾ÅÍ Àü¿ë CRAC/H À¯´Ö¿¡ Àû¿ëµÇ´Â ƯȭµÈ ½ÃÇèÁ¶°Ç°ú ±¹³»ÀÇ °øÁ¶?³Ã°¢ ½Ã½ºÅÛÀÇ ½ÃÇè±âÁØÀ» °ËÅäÇÏ¿© ÇÕ¸®ÀûÀÎ ¼º´ÉÆò°¡¸¦ À§ÇÑ ´ë¾ÈÁ¶°ÇÀ» Á¦½ÃÇÏ¿´°í, À̸¦ ¹ÙÅÁÀ¸·Î ½ÇÇè´ë»ó CRAC À¯´ÖÀº ±× »ç¿ë ¸ñÀû¿¡ ¸Â´Â ITȯ°æÀ» ¹Ý¿µÇÑ ¿î¿µÁ¶°Ç¿¡¼­ ½ÇÁ¦·Î ¾ò°íÀÚ ÇÏ´Â ³Ã¹æ´É·ÂÀ» È®º¸ÇÒ ¼ö ÀÖÀ½À» È®ÀÎ ÇÒ ¼ö ÀÖ¾ú´Ù.




±¹³» IT±â¼ú°ú À̸¦ ±¸ÇöÇÏ´Â µ¥ÀÌÅͼ¾ÅÍ °Ç¼³ ¿£Áö´Ï¾î¸µ ±â¼úÀº ¾çÀû, ÁúÀûÀ¸·Î ¼¼°èÀûÀÎ ¼öÁØÀÌ´Ù. ±×·¯³ª ½ÇÁúÀûÀÎ ¿î¿µ´Ü°è °øÁ¶?³Ã°¢¼º´ÉÀ» È®º¸¸¦ À§ÇÑ µ¥ÀÌÅͼ¾ÅÍ¿¡ Ư¼ö¼ºÀÌ ¹Ý¿µµÈ ÀåºñÀÇ ¼º´ÉÆò°¡ ½ÃÇè ¹× ±âÁØÀÌ ¹ÌÈíÇß´Ù. ÇâÈÄ ±¹°¡Ç¥Áذú ¿¬°èÇÏ¿© ¼º´ÉÆò°¡¸¦ À§ÇÑ ½ÃÇèÀýÂ÷¸¦ º¸´Ù ±¸Ã¼È­ÇÔÀ¸·Î½á ±âÃÊÀÚ·á·Î Ȱ¿ëÀÌ °¡´ÉÇÒ °ÍÀ¸·Î ÆÇ´ÜµÈ´Ù.
¿ä¾à2 he purpose of this study was to establish a uniform set of requirements for rating computer room air conditioning/handling (CRAC/H) units for dedicated cooling systems in data centers. With the revolution of Industry 4.0, there are many options for data center infrastructure. The next generation of hyper-scale data centers will no longer be limited to past cooling facilities, but will seamlessly integrate the new cooling systems becoming increasingly optimized and mission-critical. For data centers, there are four basic heat removal methods, with air-cooled, water-cooled, glycol-cooled, and chilled-water system, to cool IT equipment and to transport unwanted heat to the outdoor environment. And air distribution systems, room-based, row-based, and rack-based cooling methods, have been developed to address cooling problems. Data center cooling technology is also advancing and improving and new types of CRAC/H units and cooling procedures are being developed. But performance tests of cooling systems do not fully reflect all types of CRAC/H units, data center cooling mechanisms, and data center thermal guidelines for IT environments. Standards and guidelines for performance testing were analyzed by foreign and domestic cases. In this paper, a suggested performance test condition is included in the CRAC/H classification, test requirements, and rating requirements.
¼ÒÀåó ´ëÇѼ³ºñ°øÇÐȸ
¾ð¾î Çѱ¹¾î
DOI https://doi.org/10.6110/KJACR.2020.32.5.235
ºÐ¼®¼­Áö
°ÇÃàȯ°æ ¹× ¼³ºñ > °ÇÃ༳ºñ > ¿­¿ø¼³ºñ

°ÇÃàȯ°æ ¹× ¼³ºñ > °ÇÃ༳ºñ > °øÁ¶¼³ºñ

¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
µ¥ÀÌÅͼ¾ÅÍ ±â°è¼³ºñ ¼³°è½Ã °í·Á»çÇ×
±èÀçÇå(Jae Heon Kim) ; À̼º±¸(Sung Goo Lee) ; ¿¬Ã¢±Ù(Chang Kum Yeon) - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (201711)
[ƯÁý¿ø°í] µ¥ÀÌÅͼ¾ÅÍ ¼³°è±âÁØ ¹× ¿¡³ÊÁö È¿À²È­
Á¶Áø±Õ - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : Vol.34 No.03 (201703)
[ƯÁý¿ø°í] µ¥ÀÌÅͼ¾ÅÍ °ÇÃà°èȹ
¼ÕÁö¼ö - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : Vol.34 No.03 (201703)
[ƯÁý¿ø°í] µ¥ÀÌÅͼ¾ÅÍ ³Ã¹æ½Ã½ºÅÛ ¼³°è»ç·Ê ºñ±³
±è¿µ¹ü - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.27 n.05 (201005)
¿Ü±â³Ã¹æ½Ã½ºÅÛÀÌ Àû¿ëµÈ µ¥ÀÌÅͼ¾ÅÍ CRAHÀÇ ±Þ±â¿Âµµ¿Í ¼³°è dz·®¿¡ µû¸¥ ¿¡³ÊÁö¼º´É ºÐ¼®
±èÁöÇý(Kim, Ji-Hye) ; ¾öÅÂÀ±(Aum, Tae-Yun) ; Á¤Â÷¼ö(Jeong, Cha-Su) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý ±¸Á¶°è : Vol.35 No.11 (201911)
¿Ü±â°£Á¢Áõ¹ß ³Ã°¢¿¡ ÀÇÇÑ ¿¡³ÊÁöÀý¾à µ¥ÀÌÅͼ¾ÅÍ ¼³°è»ç·Ê
ÀÌÁ¾Çü(Jong Hyung Lee) ; °­È­¿µ(Hwa Young Kang) - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (201711)
[ƯÁý¿ø°í] µ¥ÀÌÅͼ¾ÅÍ °øÁ¶½Ã½ºÅÛ ¼Ò°³
ÃÖº´³² - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : Vol.34 No.03 (201703)
±âÁ¸ µ¥ÀÌÅͼ¾ÅÍÀÇ ±¸¿ª´ÜÀ§ ¿¡³ÊÁö È¿À²Æò°¡ ¹æ¹ý ¹× PUE ±â¹Ý M&V º£À̽º¶óÀÎ ¸ðµ¨ °³¹ß
Á¶Áø±Õ(Jinkyun Cho) ; È«¿øÇ¥(Won-Pyo Hong) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.32 No.2 (202002)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
µ¥ÀÌÅͼ¾ÅÍÀÇ ±Þ±â¿Âµµ º¯È­°¡ ¼­¹ö ³Ã°¢ ¼º´É¿¡ ¹ÌÄ¡´Â ¿µÇâ¿¡ ´ëÇÑ ¿¬±¸
ÀåÇöÀç(Hyun Jae Chang) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.30 No.02 (201802)
¡á Á¦ 1 ÀúÀÚÀÇ ´Ù¸¥ ¹®Çå ½Äº°ÀúÀÚ´õº¸±â
[ÇØ¿Ü¹®Çå] ASHRAE Standards90.1 ¹× 90.4ÀÇ µ¥ÀÌÅͼ¾ÅÍ ¿¡³ÊÁö °ü·Ã Áؼö»çÇ×
Á¶Áø±Õ - ¼³ºñÀú³Î(´ëÇѼ³ºñ°øÇÐȸÁö) : Vol.51 No.3 (202203)
¿­È¸¼öÇüȯ±âÀåÄ¡ÀÇ ¼º´É ÇöȲ ¹× Æò°¡¹æ¹ý¿¡ °üÇÑ ¿¬±¸
¹Úº´¿ë(Beungyong Park) ; Á¶Áø±Õ(Jinkyun Cho) ; ¿Àº´Ã¶(Byoungchull Oh) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.34 No.03 (202203)
È¿À²ÀûÀÎ ±¹°¡ °¨¿°º´ ´ëÀÀÀ» À§ÇÑ À̵¿Çü À½¾Ð°Ý¸®º´½Ç ±âÁظ𵨠¹× °øÁ¶½Ã½ºÅÛ ¼³°è¹æ¹ý¿¡ °üÇÑ ¿¬±¸
Á¶Áø±Õ(Cho, Jinkyun) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý : Vol.38 No.1 (202201)
¹ßÀüÇ÷£Æ® ³Ã°¢¼ö °èÅë Ãë¼ö½Ã½ºÅÛÀÇ ÇØ¾ç»ý¹° ¹× ÇØÀúÅðÀû¹° À¯ÀÔ¿¡ ´ëÇÑ ¼öÄ¡ÇØ¼® »ç·Ê¿¬±¸
Á¶Áø±Õ(Jinkyun Cho) ; ±èÁøÈ£(Jinho Kim) ; ¹Úâ¿í(Chang Wook Park) ; ¼ºº´Ã¤(Byung Chae Sung) ; ¼Õ¹Î¼®(Minseok Son) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.33 No.12 (202112)
[ÇØ¿Ü¹®Çå] ±³Å俪¿¡³ÊÁö °³º¸¼ö»ç·Ê
Á¶Áø±Õ - ¼³ºñÀú³Î(´ëÇѼ³ºñ°øÇÐȸÁö) : Vol.50 No.12 (202112)
³ëÈÄ °ø°ø°ÇÃ๰ÀÇ ¿¡³ÊÁö¼º´É °³¼±À» À§ÇÑ ±×¸° ¸®¸ðµ¨¸µ Àû¿ë¼º ºÐ¼® ? A º¸°Ç¼Ò »ç·Ê¿¬±¸
Á¶Áø±Õ; Àå½Â¹Î; ÀÌÅ¿¬; À̼۹Î; À̽Âȯ - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (202111)
±³Â÷°¨¿°¹æÁö¸¦ À§ÇÑ ºñÁ¢ÃË COVID-19 ¼±º°Áø·á¼Ò ȯ±â¼º´É Æò°¡
Á¶Áø±Õ; ¹Úº´¿ë; ±èÁøÈ£; ¼ÛÁ¾¿î - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (202111)
µ¥ÀÌÅͼ¾ÅÍ ¿¡³ÊÁö¼Òºñ ±¸Á¶ ºÐ¼®
Á¶Áø±Õ - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (202111)
¼ö¹è°ü ½Ã½ºÅÛ ÃÖÀûÈ­¸¦ ÅëÇÑ µ¥ÀÌÅͼ¾ÅÍ ³Ã°¢ ¿¡³ÊÁöÀý¾à ¼³°è¹æ¾È
¹Úµ¿ÀÏ; Á¶Áø±Õ - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (202111)
Àü·Â»ç¿ë·® ±â¹ÝÀÇ ³Ãµ¿±â ÃøÁ¤°ËÁõ(M&V)À» À§ÇÑ º£À̽º¶óÀÎ ºÐ¼®¿¡ °üÇÑ ¿¬±¸
¹Úº´¿ë; Á¶Áø±Õ; ÃÖÁ¾¹Î - ´ëÇѼ³ºñ°øÇÐȸ µ¿°èÇмú¹ßǥȸ ³í¹®Áý : (202111)