°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

´ëÇÑ°ÇÃàÇÐȸ|ARCHITECTURAL RESEARCH(³í¹®Áý) 2017³â 12¿ù

³í¹®¸í Investigation on the Reduction Effect on Cooling Power Consumption and Operating Cost of Mist-spray Outdoor Units in Air Conditioner
ÀúÀÚ¸í ÀÌ°ÇÈ£ ; Á¶µ¿¿ì½Äº°ÀúÀÚ ; ±èÇý¹Ì½Äº°ÀúÀÚ ; ¼Û¿µÇÐ
¹ßÇà»ç ARCHITECTURAL INSTITUTE OF KOREA(´ëÇÑ°ÇÃàÇÐȸ)
¼ö·Ï»çÇ× ARCHITECTURAL RESEARCH(´ëÇÑ°ÇÃàÇÐȸ ³í¹®Áý), Vol.19 No.4 (2017-12)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(101) ÃÑÆäÀÌÁö(8)
ISSN 12296163
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î ; Mist Spray ; Outdoor Unit ; Evaporative Cooling ; Operating Cost ; Cooling Efficiency
¿ä¾à2 The use of the air conditioner is increasing due to the rise of the outdoor temperature during summer, and the problems of the fire and the cooling performance deterioration are caused due to lack of maintenance of the outdoor unit. In particular, overall performance of cooling system and efficiency in outdoor units have been degraded due to an intake of high-temperature outdoor air thereby increasing cooling energy and operating cost. Thus, this study aimed to increase efficiency of outdoor units by evaporating and cooling intake air through mist spray at the intake port surface in the outdoor unit. The measurements results showed that total power consumption of misting outdoor unit compared to that of conventional outdoor units was reduced by 21% approximately, and total power consumption of the entire system including pump was reduced by 16.7%. In addition, the operating cost including water use was reduced by 13.5% approximately. In summary, if a mist-spray nozzle kit is installed in air-cooled outdoor units, the reduction in the usage of cooling energy and operating cost will be achieved without replacement of existing cooling systems or a large scale of repairs.
¼ÒÀåó ´ëÇÑ°ÇÃàÇÐȸ
¾ð¾î ¿µ¾î
DOI https://doi.org/10.5659/AIKAR.2017.19.4.101
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
2025³â Àǹ«È­ ·Îµå¸Ê¿¡ µû¸¥ °ø°ø½Ã¼³ Á¦·Î¿¡³ÊÁö°ÇÃ๰ ÀÎÁõÁ¦µµ ½ÃÀå ¼ö¿ë¼º
À̽¹Î(Lee, Seung-Min) ; ±èÁøÈ£(Kim, Jin-Ho) ; ½Å±¤¼ö(Shin, Gwang-Su) ; ±èÀÇÁ¾(Kim, Eui-Jong) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.12 No.6 (201812)
°¡¿ì½Ã¾È ÇÁ·Î¼¼½º ¸ðµ¨À» ÀÌ¿ëÇÑ ³Ã°¢Å¾ ÃÖÀûÁ¦¾î
±èÀç¹Î(Kim, Jae-Min) ; ½ÅÇѼÖ(Shin, Han-Sol) ; ÃßÇÑ°æ(Chu, Han-Gyeong) ; À̵¿Çõ(Yi, Dong-Hyuk) ; ¹Ú¼ºÈ£(Park, SungHo) ; ¿©¸í¼®(Yeo, Myoung-Souk) ; ¹Úö¼ö(Park, Cheol-Soo) - Ãß°èÇмú¹ßÇ¥´ëȸ : 2018 (201811)
³Ã°¢¼ö À¯·® Á¦¾î¸¦ ÅëÇÑ ³Ã¹æ½Ã½ºÅÛÀÇ ¿¡³ÊÁö Àý°¨ È¿°ú¿¡ °üÇÑ °ËÅä
±èÇý¹Ì(Kim, Hyemi) ; ¼Û¿µÇÐ(Song, Young-hak) - ´ëÇÑ°ÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.37 No.1 (201704)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ´ë¼öÁ¦¾î¸¦ ÅëÇÑ ³Ãµ¿±â °Åµ¿ Ư¼º ¹× ¿¡³ÊÁö Àý°¨ È¿°ú ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; ¼ÕÁ¤Àº(Jeong-Eun Son) ; À̱¤È£(Kwang Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.28 No.04 (201604)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ºÎºÐºÎÇÏÀ² ¹× ³Ã¹æ ¿¡³ÊÁö ¼º´É Ư¼º ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; À¯º´È£(Byeong-Ho Yu) ; À̱¤È£(Kwang-Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.27 No.11 (201511)
IoTÁ¤º¸±â¹Ý Modelica-EnergyPlus Co-simulationÀ» ÅëÇÑ ¿¡³ÊÁö¼Òºñ·® ÃßÁ¤
±èÇýÁø(Kim, Hye-Jin) ; ¼­µ¿Çö(Seo, Dong-Hyun) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.13 No.5 (201910)
°Ç¹° ¿¡³ÊÁö ½Ã¹Ä·¹À̼ÇÀÇ À¯¿ë¼º
±è´ö¿ì(Kim, Deuk Woo) ; ¹Úö¼ö(Park, Cheol Soo) ; À̽¾ð(Lee, Seung Eon) - ´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý ±¸Á¶°è : Vol.33 No.05 (201705)
¹Ì½ºÆ® ºÐ¹« ½Ç¿Ü±âÀÇ ½Ç³»¿ÜÁ¶°Ç º¯È­¿¡ µû¸¥ ¿¡³ÊÁö Àý°¨ È¿°ú °ËÅä
±è¹Î¼®(Kim, Min-seok) ; ±èÇý¹Ì(Kim, Hyemi) ; ¼Û¿µÇÐ(Song, Young-hak) - ´ëÇÑ°ÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.37 No.1 (201704)
±â°èÇнÀ ±â¹Ý ÀÚµ¿È­ ¾Ë°í¸®ÁòÀ» È°¿ëÇÑ °øÁ¶±â ±Þ±â ¿Âµµ ¿¹Ãø
¾ÈÀ¯¼±(Yusun Ahn) ; È«±¸Ç¥(Goopyo Hong) ; ±èº´¼±(Byungseon Sean Kim) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.32 No.1 (202001)
Àΰø½Å°æ¸Á ¸ðµ¨À» ÀÌ¿ëÇÑ ³Ãµ¿±â ¹× °øÁ¶±â ÃÖÀû ±âµ¿/Á¤Áö Á¦¾î
¹Ú¼ºÈ£(Park, SungHo) ; ¾È±â¾ð(Ahn, Ki Uhn) ; Ȳ½ÂÈ£(Hwang, Aaron) ; ÃÖ¼±±Ô(Choi, Sunkyu) ; ¹Úö¼ö(Park, Cheol Soo) - ´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý ±¸Á¶°è : Vol.35 No.02 (201902)