³í¹®¸í |
Áְŵ¿À¯ÇüÀ» °í·ÁÇÑ °øµ¿ÁÖÅà ´ÜÁöÀÇ ¿¼º´É °ËÅä / Thermal Performance in Apartment with respect to Building types - Focused on Apartment complex in Haengbok-dosi, Sejong city- / ¼¼Á¾½Ã Çູµµ½Ã Áö¿ªÀ» Áß½ÉÀ¸·Î |
¼ö·Ï»çÇ× |
KIEAE Journal, Vol.17 No.3(Åë±Ç 85È£) (2017-06) |
ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(69) ÃÑÆäÀÌÁö(6) |
ÁÖÁ¦¾î |
°øµ¿ÁÖÅà ´ÜÁö ; Áְŵ¿À¯Çü ; ÄÄÇ»ÅÍ ½Ã¹Ä·¹ÀÌ¼Ç ; Apartment Building Complex ; Building Type ; Computer Simulation |
¿ä¾à2 |
Purpose: The apartment complex constructed recently is composed of very various types of building, plan, and orientation etc. However, it is difficult to remark conclusively that these various types of buildings are designed energy-effectively, since it is difficult for architects to find useful energy design guideline for decision making. By the preceding study, the present condition and problem about this subject was grasped, apartment building types were examined and representative types were extracted. Method: Large apartment building complex having 1940 households, located in haengbok-dosi, sejong city, Korea is used as an example to conduct this study. Representative building types are extracted first. Then, heating and cooling load of households is analyzed. Lastly, effect of outdoor air cooling is investigated by computer simulation. Result: Results of this research are summarized as follows: 1. Besides solar gain, household layout of building, orientation, and plan have compositive effects on heating and cooling load. 2. The effect of outdoor air cooling in apartment can be improved by arranging windows of households. |