| 논문명 |
SPC 합성보-기둥 접합부의 반복 이력 특성에 대한 실험 / Experimental Study on Hysteretic Characteristics of SPC Composite Beam to Column Connection |
| 저자명 |
김도범 ; 박호영 ; 배규웅 ; 강철규 ; 최병정 |
| 수록사항 |
한국강구조학회 학술발표대회 논문집 (2015-06) |
| 요약2 |
The SPC beam is composed of folding steel plates and concrete, without headed stud. The folding steel plate is assembled by high strength blot instead of welding. To improve the workability in field construction, a hat-shaped Cap was attached in the junction with slab. The shape of the connection applied the bracket way to the column. And shape was connected using bolt with spc beam after attaching steel plates like beam cross section in column surface. Three specimens with steel plate thickness of beam, were constructed. That was tested by experimental procedure proposed KBC2009. The result displayed internal force more than 1.1 to theoretical value, and it was satisfied the rotation capacity of 0.02 radian. |