³í¹®¸í »ç¹«¼Ò °Ç¹°ÀÇ ½ÅÀ¯È¿¿Âµµ ÄèÀûÁöÇ¥¿Í ¿¡³ÊÁö¼º´ÉÀ» °í·ÁÇÑ ³Ã¼ö°ø±Þ¿Âµµ ¼³Á¤ / The Chilled Supply Water Setting considering both Comfort Index of New Effective Temperature and Energy Performance in Office Building
ÀúÀÚ¸í ¼­´ë¿õ(Seo, Dae-Woong) ; °û³ë¿­(Kwak, Ro-Yeul)½Äº°ÀúÀÚ ; ÃÖ¼±±Ô(Choi, Sun-Kyu)½Äº°ÀúÀÚ
¹ßÇà»ç ´ëÇѰÇÃàÇÐȸ
¼ö·Ï»çÇ× ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è, Vol.32 No.04 (2016-04)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(115) ÃÑÆäÀÌÁö(8)
ISSN 1226-9093
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î Åͺ¸³Ãµ¿±â ; ³Ã¼ö°ø±Þ¿Âµµ ; ½ÅÀ¯È¿¿Âµµ ; ÄèÀûÁöÇ¥ ; ¿¡³ÊÁö Àý°¨ ; Centrifugal Chiller ; Chilled Water Supply Temperature ; New Effective Temperature ; Comfort Index ; Energy Saving
¿ä¾à2 Increasing chilled water supply temperature is recommended to save the energy as a control tool in buildings using BEMS. Though indoor humidity affects occupants' thermal sensation, health, and business efficiency work efficiency in office buildings, office building operate cooling system focusing on indoor temperature. In this study, the goal of the research is to set supply air temperature using new effective temperature comfort index which is considering both temperature and humidity and to compute chilled water supply temperature using the set supply air temperature. Therefore, to prevent indoor uncomfort of misoperation and to reach energy saving, unskilled building operator can easily set chilled water supply temperature up by suggested guide line that can set chilled water supply temperature based on mixed wet bulb temperature, chilled water flow and supply air temperature. We researched comfort distribution of buildings, and readjusted comfort range of new effective temperature limit based on report of complaint. Building of subject of study exceeded comfort range 26 ET*suggested by ASHRAE, but we arranged comfort range limit to 26.6 ET* since no complaint was reported. We proposed setting guide line to have highest chilled water supply temperature based on analysis of mixed wet bulb temperature that can consider both outdoor air and indoor air at the same time, a set supply air temperature by operator, and data of cool water flow rate passing through cooling coil to find the most appropriate chilled water supply temperature for set supply air temperature.
¼ÒÀåó ´ëÇѰÇÃàÇÐȸ
¾ð¾î Çѱ¹¾î
DOI http://dx.doi.org/10.5659/JAIK_PD.2016.32.4.115
ºÐ¼®¼­Áö
°ÇÃàȯ°æ ¹× ¼³ºñ > °ÇÃ༳ºñ > °øÁ¶¼³ºñ

¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
2025³â Àǹ«È­ ·Îµå¸Ê¿¡ µû¸¥ °ø°ø½Ã¼³ Á¦·Î¿¡³ÊÁö°ÇÃ๰ ÀÎÁõÁ¦µµ ½ÃÀå ¼ö¿ë¼º
À̽¹Î(Lee, Seung-Min) ; ±èÁøÈ£(Kim, Jin-Ho) ; ½Å±¤¼ö(Shin, Gwang-Su) ; ±èÀÇÁ¾(Kim, Eui-Jong) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.12 No.6 (201812)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ´ë¼öÁ¦¾î¸¦ ÅëÇÑ ³Ãµ¿±â °Åµ¿ Ư¼º ¹× ¿¡³ÊÁö Àý°¨ È¿°ú ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; ¼ÕÁ¤Àº(Jeong-Eun Son) ; À̱¤È£(Kwang Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.28 No.04 (201604)
³Ã°¢¼ö À¯·® Á¦¾î¸¦ ÅëÇÑ ³Ã¹æ½Ã½ºÅÛÀÇ ¿¡³ÊÁö Àý°¨ È¿°ú¿¡ °üÇÑ °ËÅä
±èÇý¹Ì(Kim, Hyemi) ; ¼Û¿µÇÐ(Song, Young-hak) - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.37 No.1 (201704)
Àç½ÇÀÚ ¹ÝÀÀÀÌ °í·ÁµÈ ¿¡ÀÌÀüÆ® ºôµù ¿¡³ÊÁö ½Ã¹Ä·¹À̼Ç
±èÁ¾Çå(Kim, Jong-Hun) ; ¹Ú»ó¸°(Park, Sang-Lin) ; ±è´ö¿ì(Kim, Deuk-Woo) ; ¹Úö¼ö(Park, Cheol-Soo) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.27 n.12 (201112)
±âÁ¸ °Ç¹° HVAC ½Ã½ºÅÛ¿¡ ´ëÇÑ ´Ù¼¸ °¡Áö ±â°èÇнÀ ¸ðµ¨ °³¹ß
¶ó¼±Áß(Ra, Seon-Jung) ; ½ÅÇѼÖ(Shin, Han-Sol) ; ¼­¿øÁØ(Suh, Won-Jun) ; ÃßÇѰæ(Chu, Han-Gyeong) ; ¹Úö¼ö(Park, Cheol-Soo) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý ±¸Á¶°è : Vol.33 No.10 (201710)
BEMS µ¥ÀÌÅ͸¦ Ȱ¿ëÇÑ Ãà¿­ ½Ã½ºÅÛÀÇ ¿îÀü ¼º´É ¹× È¿À² ÀúÇÏ Æò°¡¿¡ °üÇÑ ¿¬±¸
¹Ú¼ºÃ¶(Park, Seong-Cheol) ; ±èÀ¯Áø(Kim, Yu-Jin) ; ±èȯ¿ë(Kim, Hwan-Yong) ; ¼Û¿µÇÐ(Song, Young-Hak) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.13 No.6 (201912)
IoTÁ¤º¸±â¹Ý Modelica-EnergyPlus Co-simulationÀ» ÅëÇÑ ¿¡³ÊÁö¼Òºñ·® ÃßÁ¤
±èÇýÁø(Kim, Hye-Jin) ; ¼­µ¿Çö(Seo, Dong-Hyun) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.13 No.5 (201910)
°¡¿ì½Ã¾È ÇÁ·Î¼¼½º ¸ðµ¨À» ÀÌ¿ëÇÑ ³Ã°¢Å¾ ÃÖÀûÁ¦¾î
±èÀç¹Î(Kim, Jae-Min) ; ½ÅÇѼÖ(Shin, Han-Sol) ; ÃßÇѰæ(Chu, Han-Gyeong) ; À̵¿Çõ(Yi, Dong-Hyuk) ; ¹Ú¼ºÈ£(Park, SungHo) ; ¿©¸í¼®(Yeo, Myoung-Souk) ; ¹Úö¼ö(Park, Cheol-Soo) - Ãß°èÇмú¹ßÇ¥´ëȸ : 2018 (201811)
°ÇÃ๰ÀÇ ¿¡³ÊÁöÀý¾à¼³°è±âÁØ °­È­¿¡ µû¸¥ ¾÷¹«¿ë °Ç¹°ÀÇ ¿¡³ÊÁö¼º´É °³¼± È¿°ú
±èÁöÇý(Kim, Ji-Hye) ; ¼ºÁ¦Àº(Sung, Jea-Eun) ; ±èÇý±â(Kim, Hye-Gi) ; ¹Ú´öÁØ(Park, Duk-Joon) ; ±è¼±¼÷(Kim, Sun-Sook) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.14 No.1 (202002)