°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

Çѱ¹Àü»ê±¸Á¶°øÇÐȸ|Çмú´ëȸ ³í¹®Áý 2014³â 4¿ù

³í¹®¸í 39Ãþ ö°ñÁ¶ ±¸Á¶¹°ÀÇ ½Ã½ºÅ۽ĺ° / System Identification of 39-story Steel Structure / 24-ÃʰíÃþ °Ç¹°ÀÇ Ç³Áøµ¿Á¦¾î
ÀúÀÚ¸í ÀÌ»óÇö(Lee, Sang-Hyun) ; Á¤¶õ(Chung, Lan) ; ¿ì¼º½Ä(Woo, Sung-Sik)½Äº°ÀúÀÚ
¹ßÇà»ç Çѱ¹Àü»ê±¸Á¶°øÇÐȸ
¼ö·Ï»çÇ× Çѱ¹Àü»ê±¸Á¶°øÇÐȸ Çмú´ëȸ ³í¹®Áý, Vol.27 No.1 (2014-04)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(431) ÃÑÆäÀÌÁö(4)
ÁÖÁ¦ºÐ·ù ±¸Á¶
ÁÖÁ¦¾î ; Active Mass Damper ; System Identification ; Sine Swept Test
¿ä¾à1 º» ³í¹®¿¡¼­´Â ´Éµ¿Çü Á¦ÁøÀåÄ¡ÀÇ ½Ç½Ã°£ Á¦¾î¾Ë°í¸®Áò ±¸ÃàÀ» À§ÇØ 39Ãþ ö°ñÁ¶ ±¸Á¶¹°¿¡ ¼³Ä¡µÈ ´Éµ¿Áú·®°¨¼è±â¸¦ ÀÌ¿ëÇÑ sine swept ½ÇÇèÀ» ¼öÇàÇÏ¿©, ¸ðµåÁøµ¿¼ö, °¨¼èºñ, ±×¸®°í ¸ðµåº¤Å͸¦ ÃßÃâÇÏ¿© ½Ã½ºÅÛ Çà·ÄÀ» ±¸¼ºÇϰí, À̸¦ Á¦¾î¾Ë°í¸®Áò¿¡ ¹Ý¿µÇÏ¿© ½ÇÁ¦ Á¦ÁøÀåÄ¡ °¡Áø½Ã ¹ß»ýÇÑ ±¸Á¶¹° ÀÀ´ä°ú ÇØ¼®°á°ú¸¦ ºñ±³ÇÏ¿© ÃßÃâµÈ ¸ðµå Ư¼ºÀÇ Á¤È®¼ºÀ» È®ÀÎÇÏ¿´´Ù.
¼ÒÀåó Çѱ¹Àü»ê±¸Á¶°øÇÐȸ
¾ð¾î Çѱ¹¾î