°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

´ëÇѼ³ºñ°øÇÐȸ|¼³ºñ°øÇÐ³í¹®Áý 2014³â 12¿ù

³í¹®¸í »ý¹°¾ÈÀü¹ÐÆó½Ã¼³¿¡¼­ Multizone°ú CFD ¿¬µ¿Çؼ®¿¡ ÀÇÇÑ ½Ç³»±â·ù ¹× Influenza A ¿À¿°³óµµÇؼ® / Applications of a Coupled Multizone and CFD Simulation to Validate Airflow and Influenza A Contaminant Dispersion in Biosafety Laboratory
ÀúÀÚ¸í ȲÁöÇö(Ji Hyun Hwang) ; È«Áø°ü½Äº°ÀúÀÚ(Jin Kwan Hong)
¹ßÇà»ç ´ëÇѼ³ºñ°øÇÐȸ
¼ö·Ï»çÇ× ¼³ºñ°øÇÐ³í¹®Áý, Vol.26 No.12 (2014-12)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(588) ÃÑÆäÀÌÁö(6)
ISSN 1229-6422
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î Biosafety laboratory ; »ý¹°¾ÈÀü ¹ÐÆó½Ã¼³ ; ¸ÖƼÁ¸ ÇØ¼® ; Àü»êÀ¯Ã¼¿ªÇÐ ; ¸ÖƼÁ¸_CFD ¿¬µ¿Çؼ® ; °ø±âÀ¯µ¿ ; ÀÎÇ÷翣ÀÚA ¿À¿°³óµµ ; Biosafety laboratory ; BSL lab. ; Multizone smulation ; CFD ; Coupled multizone and CFD simulation ; Airflow ; Influenza A contaminants concentration
¿ä¾à2 To maintain a negative pressure, the supply, exhaust airvolume are adjusted by setting volume damper and the infiltration through leakage area of the door between rooms in biosafety laboratory. Multizone simulation is useful way to predict room pressure, supply and exhaust air volume. But in a particular room, local change such as airflow and contaminants concentration distribution can not be evaluated unfortunately. Through this study, a coupled multizone and CFD simulation was performed, indoor air flow and local contaminants concentration distribution in a particular room of BSL lab are predicted. The results show that all zones of BSL lab are well ventilated by unidirectional flow without local stagnation. In addition, in case that unexpected biohazard is occured in BSL lab, multizone simulation results about the spread of pollutants along movement of the occupant also show that contaminants concentration is removing totally without the spread of the outside. In conclusion, a coupled multizone and CFD simulation can be applied to interpret differential pressure in room and local change of physical quantity in a particular room such as airflow and Influenza A contaminants concentration distribution. This simulation method is useful to enhance the reliability and accuracy of biosafety laboratory design.
¼ÒÀåó ´ëÇѼ³ºñ°øÇÐȸ
¾ð¾î Çѱ¹¾î
DOI http://dx.doi.org/10.6110/KJACR.2014.26.12.588
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
2025³â Àǹ«È­ ·Îµå¸Ê¿¡ µû¸¥ °ø°ø½Ã¼³ Á¦·Î¿¡³ÊÁö°ÇÃ๰ ÀÎÁõÁ¦µµ ½ÃÀå ¼ö¿ë¼º
À̽¹Î(Lee, Seung-Min) ; ±èÁøÈ£(Kim, Jin-Ho) ; ½Å±¤¼ö(Shin, Gwang-Su) ; ±èÀÇÁ¾(Kim, Eui-Jong) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.12 No.6 (201812)
±¹³» ÆÐ½Ãºê°ÇÃ๰ ¼³°è ¹× ½Ã°ø»ç·Ê
À̸íÁÖ - Çѱ¹±×¸°ºôµùÇùÀÇȸ Ãß°èÇмú°­¿¬È¸ ³í¹®Áý : (200911)
½Ç¹«ÀÚ¸¦ À§ÇÑ º´¿ø¼³ºñÀÇ ÀÌÇØ
¹ÚÀºµ¿ ; ±èÈ¿ÁØ - ´ëÇѼ³ºñ°øÇÐȸ ÇϰèÇмú¹ßǥȸ ³í¹®Áý : (201206)
°¡¿ì½Ã¾È ÇÁ·Î¼¼½º ¸ðµ¨À» ÀÌ¿ëÇÑ ³Ã°¢Å¾ ÃÖÀûÁ¦¾î
±èÀç¹Î(Kim, Jae-Min) ; ½ÅÇѼÖ(Shin, Han-Sol) ; ÃßÇѰæ(Chu, Han-Gyeong) ; À̵¿Çõ(Yi, Dong-Hyuk) ; ¹Ú¼ºÈ£(Park, SungHo) ; ¿©¸í¼®(Yeo, Myoung-Souk) ; ¹Úö¼ö(Park, Cheol-Soo) - Ãß°èÇмú¹ßÇ¥´ëȸ : 2018 (201811)
³Ã°¢¼ö À¯·® Á¦¾î¸¦ ÅëÇÑ ³Ã¹æ½Ã½ºÅÛÀÇ ¿¡³ÊÁö Àý°¨ È¿°ú¿¡ °üÇÑ °ËÅä
±èÇý¹Ì(Kim, Hyemi) ; ¼Û¿µÇÐ(Song, Young-hak) - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : Vol.37 No.1 (201704)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ´ë¼öÁ¦¾î¸¦ ÅëÇÑ ³Ãµ¿±â °Åµ¿ Ư¼º ¹× ¿¡³ÊÁö Àý°¨ È¿°ú ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; ¼ÕÁ¤Àº(Jeong-Eun Son) ; À̱¤È£(Kwang Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.28 No.04 (201604)
[ƯÁý¿ø°í] À¯·®Á¶Àý ½Ã½ºÅÛÀÇ Àû¿ë»ç·Ê
ÀÌâ±Ù ; ¹Ú±â¹ü - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.26 n.06 (200906)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
IoTÁ¤º¸±â¹Ý Modelica-EnergyPlus Co-simulationÀ» ÅëÇÑ ¿¡³ÊÁö¼Òºñ·® ÃßÁ¤
±èÇýÁø(Kim, Hye-Jin) ; ¼­µ¿Çö(Seo, Dong-Hyun) - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : Vol.13 No.5 (201910)
»ç¹«¼Ò °Ç¹°¿¡¼­ ³Ãµ¿±âÀÇ ºÎºÐºÎÇÏÀ² ¹× ³Ã¹æ ¿¡³ÊÁö ¼º´É Ư¼º ºÐ¼®
¼­º´¸ð(Byeong-Mo Seo) ; À¯º´È£(Byeong-Ho Yu) ; À̱¤È£(Kwang-Ho Lee) - ¼³ºñ°øÇÐ³í¹®Áý : Vol.27 No.11 (201511)