건축도시공간연구소

Architecture & Urban Research Institute

pdf원문보기 에러 해결방법 바로가기



문헌홈 > 연구논문 > 상세

[원문보기시 소비되는 포인트 : 100 포인트] 미리보기 인용

한국조명전기설비학회|조명전기설비학회논문지 2014년 4월

논문명 한중일의 조도기준 비교분석 / Comparative Analysis on Recommended Levels of Illumination in KoreaㆍChina?Japan: Focused on Recommended Levels of Illumination for Housing / 주택조도기준을 중심으로
저자명 송대선(DaeSun Song) ; 강혜경식별저자(HyeKyung Kang) ; 조영미(YoungMi Jo) ; 안옥희(Ok-hee An)
발행사 한국조명전기설비학회
수록사항 조명전기설비학회논문지, Vol.28 No.04 (2014-04)
페이지 시작페이지(1) 총페이지(8)
ISSN 1225-1135
주제분류 환경및설비
주제어 ; Comparative Analysis ; Recommended Levels of Illumination for Housing
요약2 This study compared the recommended levels of illumination for housing. KS Recommended Levels of Illumination (KS A 3011) in Korea, Recommended Levels of Illumination (GB 50034-2004) in China and Recommended Levels of Illumination (JIS Z 9110) in Japan are compared. The results are as below. First, recommended levels of illumination used in KoreaㆍChinaㆍJapan are suggested by different locations and activities. However, classification for application scope is set differently. There are 10 areas for classification used in Korea, 5 areas in China, and 13 areas in China. When medium levels for classification are included as classification level, total of 15 areas are used for classification in China. Second, when considering there are 15 areas of application scope in China for recommended levels of illumination, there are 7 areas that are commonly used in KoreaㆍChinaㆍJapan. 7 areas include stadium, factories, hospitals, office, shopping center, houses and hospitals. Third, working surface is considered as the height for recommended levels of illumination in KoreaㆍChinaㆍJapan. Korea and Japan consider all working positions, standing and sitting position, when deciding the height. However, China only considers the standing position. Fourth, application scope for recommended levels of illumination for housing are classified in 16 areas in Korea, 5 in China and 18 in Japan. Thus, the application scope for recommended levels of illumination in housing in Korea is similar to Japan. However, there are only 5 areas used in China such as living room, bedroom, dining room, kitchen and sanitary room. Fifth, recommended levels of illumination is classified in 3 levels such as Lowest-Moderate-Highest while China and Japan only have standard recommended levels of illumination. Sixth, when observing recommended levels of illumination by type of activities, Japan classified the activities in greatest detail followed by Korea and then China. Seventh, Recommended levels of illumination differs by each country.
소장처 한국조명전기설비학회
언어 한국어
DOI http://dx.doi.org/10.5207/JIEIE.2014.28.4.001
■ 추천문헌 (이 문헌과 같이 본 문헌)
냉방에너지 저감을 위한 PCM적용 축열벽 시스템 연구
이규영(Kyuyoung Lee) ; 류리(Ri Ryu) ; 서장후(Janghoo Seo) ; 김용성(Yongseong Kim) - 설비공학논문집 : Vol.26 No.06 (201406)
주거공간의 실내공간별 조도기준을 위한 빛환경 연구
이정은(Jung-Eun Lee) ; 최안섭(An-Seop Choi) - 조명전기설비학회논문지 : Vol.19 No.03 (200505)
광반사를 이용한 광선반 채광시스템의 기본형상 설계 및 성능평가에 관한 연구
김정태 ; 신현구 ; 김곤 - 대한건축학회논문집 계획계 : v.19 n.3 (200303)
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
광선추적기법을 활용한 곡면형 광선반시스템 설계 및 채광성능 평가
김동수 ; 윤종호 ; 신우철 ; 이광호 - 태양에너지(한국태양에너지학회 논문집) : v.31 n.4 (201108)
축소모형을 이용한 광선반의 시환경 특성 평가 연구
조일식 ; 김병수 ; 이진숙 - 태양에너지(한국태양에너지학회 논문집) : v.23 n.3 (200309)
창호의 단열성능 간이 개선방법의 비교 분석
이성진(Lee, Sung-Jin) ; 김정국(Kim, Jeong-Gook) ; 김종훈(Kim, Jonghun) ; 정학근(Jeong, Hakgeun) ; 이진숙(Lee, Jin-Sook) ; 장철용(Jang, Cheol-Yong) - KIEAE Journal : Vol.15 No.1(통권 71호) (201502)
PV 일체형 분할 광선반 시스템을 이용한 실내 주광 활용도 및 발전 효율 향상 검토
김기훈(Gi-Hoon Kim) ; 성민기(Minki Sung) ; 최안섭(An-Seop Choi) - 한국생활환경학회지 : Vol.23 No.6 (201612)
조명해석 프로그램을 이용한 광선반의 적정크기 선정 및 채광성능분석에 관한 연구
조일식(Cho Yil-Sik) ; 김병수(Kim Byoung-Soo) ; 이진숙(Lee Jin-Sook) - 대한건축학회논문집 계획계 : v.20 n.6 (200406)
단열시트(뽁뽁이)의 종류 및 부착위치에 따른 창호의 단열성능 평가
황 제(Je Hwang) ; 정아희(Ah Hee Jeong) ; 전병헌(Byung Heoun Jeon) ; 안영철(Young Chull Ahn) - 설비공학논문집 : Vol.27 No.09 (201509)