| ³í¹®¸í |
°ÇÃà¿ë ´Ü¿ÀçÀÇ Àå±â °æ½Ãº¯È¿¡ µû¸¥ ¿¼º´É Ư¼º / The Thermal Performance of Building Insulation Materials According to Long-Term Aging |
| ÀúÀÚ¸í |
ÃÖº¸Çý (Bo-Hye Choi) ; °Àç½Ä(Jae-Sik Kang) |
| ¼ö·Ï»çÇ× |
¼³ºñ°øÇÐ³í¹®Áý, Vol.25 No.11 (2013-11) |
| ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(617) ÃÑÆäÀÌÁö(7) |
| ÁÖÁ¦¾î |
¿ÀüµµÀ² ; ¿ÀüµµÀúÇ× ; ´Ü¿ÀçÀå±â °æ½Ãº¯È ; Thermal conductivity ; Thermal resistance ; Insulation materials ; Long-term aging |
| ¿ä¾à2 |
This study is to draw thermal property data during long-term aging, by testing the thermal conductivity of building insulation materials in Korea. The thermal resistance of extruded insulation within 3 days from manufacture performed well over the KS Standard. After 50 to 110 days, however, the thermal performance had deteriorated to the level of the KS standard. Eventually, after 4,000 days, the insulation performance had deteriorated to about 25.4~41.8% of the initial performance. Therefore, this research will be utilized as a reference for thermal properties during long-term aging, in order to improve standards and regulations related to building insulation materials. |