°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

´ëÇѰÇÃàÇÐȸ|´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è 2010³â 9¿ù

³í¹®¸í CCGT(Chicago Center for Green Technology) °Ç¹° »ç·Ê¿¡¼­ÀÇ ½ÇÃø°ú °ËÁõÀ» ÅëÇÑ ¿¡³ÊÁö ¼Òºñ·® ¹× ģȯ°æ °Ç¹° °ü¸®¿¡ °üÇÑ ¿¬±¸ / Actual Energy Consumption and Green Building Management Using Measurement and Verification for CCGT(Chicago Center for Green Technology)
ÀúÀÚ¸í °íµ¿È¯½Äº°ÀúÀÚ(Ko Dong-Hwan) ; ±èÇüÀϽĺ°ÀúÀÚ(Kim Hyeong-Ill)
¹ßÇà»ç ´ëÇѰÇÃàÇÐȸ
¼ö·Ï»çÇ× ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è, v.26 n.09 (2010-09)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(217) ÃÑÆäÀÌÁö(10)
ISSN 12269093
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î ģȯ°æ °ÇÃ๰ ÀÎÁõ ; ½ÇÁ¦¿¡³ÊÁö »ç¿ë·® ; ÃøÁ¤ ¹× °ËÁõ ; ¿¡³ÊÁö Àý°¨·ü ; Green Building Certification ; Actual Energy consumption ; Measurement & Verification ; Energy Conservation
¿ä¾à2 Currently, green building certification is an essential requirement for every building. In order to obtain this certification, pre-evaluation of building simulation is also required to evaluate building energy efficiency and conservation using various sustainable building strategies and technologies. However, the actual energy consumption and conservation should be verified after a building is occupied. This study focuses on the CCGT, a building that received LEED Platinum certification. Initially, various green building strategies and renewable energy technologies were introduced. Subsequently, an analysis of measurement and verification (M&V) was carried out; it consisted of the following four parts. First, the actual energy consumption was compared with the predicted simulation annual consumption. Second, some problems related to energy usage were found during building inspections. In particular, the dimming control system was not functional during the entire year, and around half of the building was not occupied. Moreover, calculation of the actual LPD(lighting power density) showed that the measured LPD was higher than the LPD derived from simulation. After changing the simulation input file on the basis of present building conditions, the annual consumption, as estimated using the new DOE2.1E simulation, was compared with the actual energy usage. Third, the problem encountered in verifying the energy conservation using renewable energy was considered. Pre-simulation indicated 42 % gas conservation, but the actual usage was higher at around 45%. Moreover, when the building was fully occupied, the actual gas consumption was 270% higher than the simulation prediction; this is even higher than the baseline simulation model without GSHP (ground source heat pump). Also the use of photovoltaic (PV) systems was monitored; however, collected data indicated that just 13% of the predicted annual electric generation would be from PV systems. Thus, it has been concluded that although pre-design and evaluation are significant factors for obtaining certification, the most important aspects are green building M&V of actual energy consumption. In a manner similar to LEED M&V, systematic analysis and management are essential for developing green and energy efficient buildings, especially for obtaining green building certification.
¼ÒÀåó ´ëÇѰÇÃàÇÐȸ
¾ð¾î Çѱ¹¾î
ºÐ¼®¼­Áö
°ÇÃàȯ°æ ¹× ¼³ºñ > ¿¡³ÊÁö > °Ç¹°¿¡³ÊÁö

ÀÌ ¿¬±¸´Â CCGT(Chicago Center for Green Technology) °Ç¹°¿¡¼­ ģȯ°æ ±â¹ýµéÀÇ Àû¿ë¿¡ µû¸¥ ¿¡³ÊÁö Àý°¨ È¿°ú¸¦ ºÐ¼®Çϰí, ÇöÀç °Ç¹° Á¶°ÇÀ» ±â¹ÝÀ¸·Î ½Ã¹Ä·¹À̼ÇÀ» ¼öÇàÇÏ¿© ½ÇÁ¦ ¿¡³ÊÁö ¼Òºñ·®°ú ºñ±³Æò°¡ÇÏ¿´´Ù. ÀúÀڴ ģȯ°æÀÎÁõÁ¦µµ¿¡¼­ ÃøÁ¤ ¹× °ËÁõÀÇ Ç׸ñÀ» ÅëÇØ ģȯ°æ °ÇÃ๰ÀÇ ÀÎÁõ ÈÄ »çÈÄ °ü¸®ÀÇ Á߿伺À» ÁöÀûÇÏ¿´À¸¸ç, °ÅÁÖ ÈÄ °Ç¹°ÀÇ ¿¡³ÊÁö ¹× ¼º´É Æò°¡°¡ ģȯ°æ °ÇÃ๰ Á¦µµ¿¡ Æ÷ÇԵǾî¾ß ÇÏ´Â µîÀÇ °³¼±¹æ¾ÈÀ» Á¦¾ÈÇÏ¿´´Ù.
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
±¹³» ÆÐ½Ãºê°ÇÃ๰ ¼³°è ¹× ½Ã°ø»ç·Ê
À̸íÁÖ - Çѱ¹±×¸°ºôµùÇùÀÇȸ Ãß°èÇмú°­¿¬È¸ ³í¹®Áý : (200911)
LEED 2009¿Í ±¹³» ģȯ°æ°ÇÃ๰ ÀÎÁõÁ¦µµ¿¡¼­ÀÇ °Ç¹°¿¡³ÊÁö È¿À²Æò°¡±âÁØ¿¡ µû¸¥ ¿¡³ÊÁö Àý°¨·ü°ú ¿¬°£¼Òºñ·® ¿¬±¸
°íµ¿È¯(Ko Dong-Hwan) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.05 (201005)
°Ç¹° ȯ°æ ¼º´É ¹× ¿¡³ÊÁö È¿À² Æò°¡¸¦ ÅëÇÑ BIM ±â¹Ý ģȯ°æ¼³°è ÇÁ·Î¼¼½º ¿¬±¸
°íµ¿È¯(Ko Dong-Hwan) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.09 (201009)
Àúź¼Ò ½Ã´ëÀÇ Ä£È¯°æ°ÇÃ๰ ±â¼ú/»ç·Ê
Á¶¿íÈñ - (»ç)Çѱ¹±×¸°ºôµùÇùÀÇȸ ⸳ 10Áֳ⠱â³ä´ëȸ : (201004)
[ƯÁý] ģȯ°æ °ÇÃ๰ÀÇ °³³ä ¹× °èȹ ¹æ¹ý
À±Á¾È£ - °ÇÃàȯ°æ¼³ºñ(Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸÁö) : v.1 n.2 (200710)
ģȯ°æ °ÇÃ๰ ÀÎÁõÀ» À§ÇÑ LEED 2009¿¡ ´ëÇÑ ¿¬±¸
°íµ¿È¯ - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : v.3 n.4 (200912)
[±×¸°ºôµù Á¤º¸] ±¹³» LEED ÀÎÁõÀ» À§ÇÑ ¼¼ºÎÆò°¡Ç׸ñ ¹× Àû¿ë»ç·Ê
¼­¿µ¹Î ; ±è´ëÈ£ ; ÀÌÁ¾À± - ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.11 n.3 (201009)
ÇÁ·Î±×·¥°ú ´ÙÀ̾î±×·¥ÀÇ Àû¿ëÀ» ÅëÇÑ °ÇÃà ÇüÅ »ý¼º ¿¬±¸
À±Çý°æ(Yoon Hae-Kyung) ; ±èÁÖ¿µ(Kim Ju-Young) ; È«¿øÈ­(Hong Won-Hwa) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.02 (201002)
¹Ì±¹ÀÇ Ä£È¯°æ°ÇÃ๰ »ç·Ê
±è»ï¿­ - Çѱ¹±×¸°ºôµùÇùÀÇȸ Ãá°èÇмú°­¿¬È¸ ³í¹®Áý : (200804)
¡á Á¦ 1 ÀúÀÚÀÇ ´Ù¸¥ ¹®Çå ½Äº°ÀúÀÚ´õº¸±â
[Remodeling Focus] Oldest but Goodest : GREEN REMODELING
°íµ¿È¯ - Remodeling(Çѱ¹¸®¸ðµ¨¸µÇùȸÁö) : Åë±Ç Á¦40È£ (201106)
°Ç¹° ȯ°æ ¼º´É ¹× ¿¡³ÊÁö È¿À² Æò°¡¸¦ ÅëÇÑ BIM ±â¹Ý ģȯ°æ¼³°è ÇÁ·Î¼¼½º ¿¬±¸
°íµ¿È¯(Ko Dong-Hwan) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.09 (201009)
[ÀÚÀ¯±â°í] Autodesk ECOTECT Analysis 2010À» ÀÌ¿ëÇÑ Ä£È¯°æ °ÇÃ๰ Æò°¡ ¹× ºÐ¼®
°íµ¿È¯ - °ÇÃà(´ëÇѰÇÃàÇÐȸÁö) : v.54 n.07 (201007)
±â»óµ¥ÀÌÅÍ ±â¹Ý µ¿Àû ÀÚ¿¬Ã¤±¤ ½Ã¹Ä·¹À̼ÇÀ» ÀÌ¿ëÇÑ À¯¿ëÁ¶µµ ºÐ¼®¿¡ °üÇÑ ¿¬±¸
°íµ¿È¯(Ko Dong-Hwan) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.06 (201006)
LEED 2009¿Í ±¹³» ģȯ°æ°ÇÃ๰ ÀÎÁõÁ¦µµ¿¡¼­ÀÇ °Ç¹°¿¡³ÊÁö È¿À²Æò°¡±âÁØ¿¡ µû¸¥ ¿¡³ÊÁö Àý°¨·ü°ú ¿¬°£¼Òºñ·® ¿¬±¸
°íµ¿È¯(Ko Dong-Hwan) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.05 (201005)
ģȯ°æ °ÇÃ๰ ÀÎÁõÀ» À§ÇÑ LEED 2009¿¡ ´ëÇÑ ¿¬±¸
°íµ¿È¯ - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : v.3 n.4 (200912)
¼Ò±Ô¸ð »ç¹«°ø°£¿¡¼­ °Ç¹° °³±¸ºÎ¿¡ µû¸¥ Á¶¸í¿¡³ÊÁö ¼º´ÉÆò°¡¸¦ À§ÇÑ ³ë¸ð±×·¡ÇÁ °³¹ß
°íµ¿È¯(Ko Dong-Hwan) ; ±èÇѼº(Kim Han-Sung) ; Á¶µ¿¿ì(Jo Dong-Woo) ; ±è°­¼ö(Kim Kang-Soo) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.20 n.3 (200403)
Áß±Ô¸ð »ç¹«°ø°£¿¡¼­ Á¶¸í¿¡³ÊÁö ¼º´ÉÆò°¡¸¦ À§ÇÑ ³ë¸ð±×·¡ÇÁ °³¹ß¿¡ °üÇÑ ¿¬±¸
±èÇѼº ; °íµ¿È¯ ; ±è°­¼ö - ž翡³ÊÁö(Çѱ¹Å¾翡³ÊÁöÇÐȸ ³í¹®Áý) : v.23 n.3 (200309)