This study measured the thermal environment and residents' cooling behavior of the apartments' living rooms in summer in Seoul. The purpose of this study is to find out the present thermal environment of the living rooms and to find out the target figure of passive cooling system. The surveys and measurements took place in six apartments of Seoul for 60days(2004. 7. 3~2004. 8. 31). The result were summarized as follows; The thermal environment of apartments' living rooms were almost neutral, and residents felt a little uncomfortable. Residents turned on the air conditioner at 27.31¡Éof indoor temperature, and 28.89¡Éof SET*. Therefore, cooling critical temperature of the passive cooling system can be figured out from this result. |