³í¹®¸í |
³Ã¡¤³¹æ ºÎÇÏ°è»êÀ» À§ÇÑ Àü±¹ 17°³ µµ½ÃÀÇÇ¥Áرâ»óµ¥ÀÌÅÍ ¹× TAC ¸Ê ÀÛ¼º / Preparation The Standard Weather Data and TAC Mapfor Heating and Cooling Load Calculation in the 17-provinces of Korea |
ÀúÀÚ¸í |
±èȯ¿ë (Kim Hwan-Yong) ; ÀÌÁ¤Àç(Yee Jurng-Jae) |
¼ö·Ï»çÇ× |
´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý °èȹ°è, v.23 n.9 (2007-09) |
ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(197) ÃÑÆäÀÌÁö(8) |
ÁÖÁ¦¾î |
Ç¥Áرâ»óµ¥ÀÌÅÍ ; TAC ; °Ç±¸¿Âµµ ; »ó´ë½Àµµ ; Standard Weather Data ; TAC ; Dry Bulb Temperature ; Relative Humidity |
¿ä¾à1 |
ÃÖ´ë ³Ã?³¹æºÎÇÏ °è»ê¹ýÀº ¿Ü±âÁ¶°ÇÀÌ °¡Àå ºÒ¸®ÇÑ »óÅ¿¡¼ ³Ã?³¹æ ºÎÇϸ¦ °è»êÇÏ´Â ¹æ¹ýÀ¸·Î ³Ã?³¹æ ÀåÄ¡ ¿ë·®À» °áÁ¤Çϴµ¥ ÀÖ¾î È¿°úÀûÀ̳ª ¿¡³ÊÁö È¿À² Ãø¸é¿¡¼ ºñ°æÁ¦ÀûÀÌ µÇ±â ½±´Ù. ÀÌ¿¡ ´ëÀÀÇϱâ À§ÇØ ASHRAE??TAC(Technical Advisory Committee)¿¡¼ À§Çè·ü 2.5¢¦10£¥ ¹üÀ§ ³»¿¡¼ ¼³°èÁ¶°ÇÀ» »ïÀ» °ÍÀ» ÃßõÇÏ°í ÀÖ´Ù. TAC ¿Âµµ¶õ ³Ã?³¹æÀåÄ¡ÀÇ ¿ë·®À» °áÁ¤Çϱâ À§ÇØ?? ³Ã³¹æ ¼³°è¿ë ¿Ü±âÁ¶°ÇÀ» ÃÖÀú¿Âµµ·Î ¼³Á¤ÇÑ °ÍÀ¸·Î½á ¿¬Áß ±ØÈ÷ ÀûÀº ½Ã°£À¸·Î ÀÎÇØ ÀåºñÀÇ ¿ë·®ÀÌ °ú´ëÇØÁö´Â °ÍÀ» ¹æÁöÇϱâ À§ÇØ ÃÊ°ú È®·üÀÇ °³³äÀ» µµÀÔÇÑ ¿ÂµµÀÌ´Ù. Áï ¿Ü±â¿Âµµ¸¦ ÃÖ°í(¿©¸§), ÃÖÀú(°Ü¿ï)·Î ÇÏÁö ¾Ê°í Á¶±Ý??³·°Ô ¶Ç´Â ³ô°Ô Àâ¾Æ¼ ÀåÄ¡¿ë·®À» °áÁ¤ÇÔÀ¸·Î½á ÀåÄ¡??¿ë·®À» ÁÙÀÌ°í, ÀÌ·Î ÀÎÇØ ÃʱâÅõÀÚºñ¸¦ »è°¨Çϸç, ºÎºÐ ºÎÇϽà ±â±âÈ¿À²À» Çâ»ó½Ãų ¼ö Àֱ⠶§¹®¿¡ ¿¡³ÊÁöÀý¾à¿¡ ±â¿©ÇÑ´Ù°í ÇÒ ¼ö ÀÖ´Ù. ³Ã?³¹æ ºÎÇÏ°è»êÀ» À§ÇØ °¢ Áö¿ª¸¶´Ù Ç¥Áرâ»óµ¥ÀÌÅÍ ÀÛ¼º°ú TAC ¿Âµµ ¼³Á¤ÀÌ ÇÊ¿äÇÏ´Ù. ±¹¿ÜÀÇ °æ¿ì, ÀÌ·¯ÇÑ ¿¬±¸°¡ ±â»óûÀ¸·ÎºÎÅÍÀÇ °üÃøµ¥ÀÌÅ͸¦ ¹ÙÅÁÀ¸·Î ºñ±³Àû È°¹ßÈ÷ ÀÌ·ç¾îÁ® TAC ¿Âµµ°¡ ÀÚÁÖ ¼öÁ¤µÇ°í ÀÖ´Â ¹Ý¸é??±¹³»¿¡¼´Â ÀÌ¿¡ ´ëÇÑ ¿¬±¸°¡ ¹ÌÈíÇÑ ½ÇÁ¤ÀÌ´Ù. º» ¿¬±¸ÀÇ ¸ñÀûÀº 2003³â °Ç¼³±³ÅëºÎ¿¡¼ Á¦½ÃµÇ¾îÁø °ÇÃ๰ ¿¡³ÊÁöÀý¾à ¼³°è±âÁØÀÇ ¼³°è¿ë ¿Ü±â¿Âµµ¿¡ ºñÇØ º¸´Ù ÃÖ±ÙÀÇ ½ÇÃøµÇ¾îÁø 10³â°£ÀÇ ±â»óµ¥ÀÌÅ͸¦ ¹ÙÅÁÀ¸·Î Ç¥Áرâ»óµ¥ÀÌÅÍ¿Í TAC ¿Âµµ¸¦ ÀÛ¼ºÇÏ°íÀÚ ÇÑ´Ù. º» ¿¬±¸¿¡¼ »ç¿ëÇÑ ÀÚ·á´Â ±â»óû¿¡¼ ÃøÁ¤ÇÑ 1996³âºÎÅÍ 2005³â±îÁö ÃÖ±Ù 10³â°£ ¼¿ï, ±¤ÁÖ, ´ë±¸, ºÎ»ê µî 17°³ µµ½ÃÀÇ ¸Å½Ã°£ ¶Ç´Â ÀÏÁ¤°£°ÝÀ¸·Î ÃøÁ¤ÇÑ ±â¿Â, »ó´ë½Àµµ, Àϻ緮 ÀÚ·áÀÌ¸ç °¢ ±â»óµ¥ÀÌÅÍ¿¡¼ ¿ùÆò±Õ ±â¿Â, ¿ùÆò±Õ »ó´ë½Àµµ, ¿ùÀû»ê Àϻ緮À» ±¸ÇÏ¿© Ç¥Áرâ»óµ¥ÀÌÅ͸¦ ÀÛ¼ºÇÏ°í, TAC 2.5£¥, 5£¥ÀÇ ¼³°è¿ë ¿Â?½Àµµ Á¶°ÇÀ» ÀÛ¼ºÇÏ°íÀÚ ÇÑ´Ù. |
¿ä¾à2 |
Indoor and outdoor temperature settings are needed to calculate the cooling & heating load. Generally, in case of indoor it is needed to be set between thermal comfort zones regardless of their region in case of indoor temperature. For outdoor temperature, it is shown differently by their regional characters which depend on their altitude & longitude. Therefore TAC temperature setting is needed for writing out the standard weather data and calculating heating & cooling loads in each region. In other countries, there are lots of TAC temperature updates based on exact data by this research but for our country it is yet inactive due to the lack of research experience. The purpose for this research is that by setting temperature standard based on recent weather data compare to the Building Energy Saving Design Standard of Ministry of Construction and Transportation for planning more practical design of heating & cooling based on accurate and variable TAC temperature standard in each regional building usage.In this study, we collected main 17-provinces of Korea's recent 10 years data on every hour or fixed interval of temperature, relative humidity, solar radiation amount and used it to get monthly average temperature, relative humidity and monthly accumulated solar radiation amount. And we used these data to write standard weather data and to find out 2.5%, 5% of TAC's temperatures. |