| ³í¹®¸í |
°í´Ü¿ âȣ½Ã½ºÅÛÀÇ ±¸¼ººÎÀç º¯È¿¡ µû¸¥ ¿°ü·ùÀ² Æò°¡¿¬±¸ / The U-Value Evaluation of High Performance Window System according to Various Material / ÅÂ¾ç¿ °Ç¹°ºÐ°ú¥° |
| ¼ö·Ï»çÇ× |
Çѱ¹Å¾翡³ÊÁöÇÐȸ Ãá°èÇмú¹ßǥȸ ³í¹®Áý (2007-04) |
| ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(100) ÃÑÆäÀÌÁö(6) |
| ÁÖÁ¦¾î |
¿°ü·ùÀ² ; U-Value ; À¯¸® ; Glass ; ÇÁ·¹ÀÓ ; Frame ; °£ºÀ ; Spacer ; °ø±âÃþ ; Gap ; ·ÎÀÌÄÚÆÃ ; Low-e Coating ; âȣ¼º´ÉÁöÇ¥ ; Window performance index |
| ¿ä¾à1 |
º» ¿¬±¸¿¡¼´Â âȣ¸¦ ±¸¼ºÇÏ´Â À¯¸®, ÇÁ·¹ÀÓ, °£ºÀÀÇ ÀçÁú°ú Å©±â µîÀ» º¯È½ÃÄÑ ´Ü¿¼º´ÉÀ» Æò°¡ÇÔÀ¸·Î¼ ±¹³»ÀÇ ´ëÇ¥Àû °í´Ü¿ âȣ½Ã½ºÅÛ¿¡ ´ëÇÑ ´Ü¿¼º´ÉÀ» Æò°¡ÇÏ´Â µ¥ ¿¬±¸ÀÇ ¸ñÀûÀÌ ÀÖ´Ù. |
| ¿ä¾à2 |
Window System has a problem with insulation on building wall comparison with other portions. Recently, in all over the world, technologies and research for improvement of insulation performance with window system were actively studied. This study has been considered about components of window system and evaluated insulation performance of triple window system through the tests of U-Value of window system and simulated model. It was evaluated window system that widely used in domestic or overseas. Therm5.0 and Window5.0 were used for simulation available for heat analysis from stationary state of two-dimensional simulated model. As a result, the best components of each portion on window system were PVC frame, Plastic spacer and Low-e glass and the super insulation window system was triple glazing window system applied these components. The U-Value of this super insulation triple window system was 1.325W/§³K and it will be expected saving energy window system. |