| ³í¹®¸í |
Á¦·Î¿¡³ÊÁö žç¿ÁÖÅÃÀÇ ½ÇÁõ½ÃÇè ¿¬±¸ / Experimental study on the Zero Energy Solar House / ÅÂ¾ç¿ ºÐ°ú¥° |
| ÀúÀÚ¸í |
¹é³²Ãá ; À±Á¾È£ ; À±ÀÀ»ó ; À¯Ã¢±Õ ; ÁÖ¹®Ã¢ ; ¼Õ¼±¿ì |
| ¼ö·Ï»çÇ× |
Çѱ¹Å¾翡³ÊÁöÇÐȸ Ãá°èÇмú¹ßǥȸ ³í¹®Áý (2007-04) |
| ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(48) ÃÑÆäÀÌÁö(6) |
| ÁÖÁ¦¾î |
Á¦·Î¿¡³ÊÁö ¼Ö¶óÇϿ콺 ; Zero energy solar house ; ¼³ºñÇüÅÂ¾ç¿ ½Ã½ºÅÛ ; Active solar system ; Áö¿È÷Æ®ÆßÇÁ½Ã½ºÅÛ ; Geo-thermal heat pump system ; žçÀÇÁ¸À² ; Solar fraction |
| ¿ä¾à1 |
º» ¿¬±¸¿¡¼´Â 70%ÀÇ ¿¡³ÊÁö¸¦ ÀÚ¸³ÇÒ ¼ö ÀÖµµ·Ï ¼³°è ½Ã°øµÈ Á¦·Î¿¡³ÊÁö ¼Ö¶óÇϿ콺 µ¥¸ð ÁÖÅÃÀÎ, KIER ZeSH¸¦ ´ë»óÀ¸·Î ³¹æ±â µ¿¾È ¼º´ÉÃøÁ¤ ½ÇÇèÀ» ¼öÇàÇÏ¿©, ¿ºÎÇÏÀÇ ÀÚ¸³µµ¿¡ ´ëÇÑ Æò°¡¸¦ ½Ç½ÃÇÏ¿´´Ù. |
| ¿ä¾à2 |
This study is on the evaluation of KIER Zero Energy Solar House(ZeSH). This ZeSH was designed and constructed for the goal of 70% self sufficiency only thermal loads. Various innovative technologies for reducing thermal load such as super insulation, high performance window, passive solar systems, ventilation heat recovery system , etc are applied in this ZeSH. In this study, the performance of the active solar heating system with geothermal heat pump as an auxiliary energy system and the energy self sufficiency rate are especially analyzed by experiment. Indoor setting temperature of ZeSH is 20¡É throughout the experimental period. As a result, the performance of active solar system is 35 to 40% depending on the various ambient condition and the solar fraction for heating season is about 74%. |