°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > ¿¬±¸³í¹® > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 100 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â Àοë

Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ|³í¹®Áý 2006³â 2¿ù

³í¹®¸í ÃæÃ»Áö¿ª °øÁßÈ­Àå½Ç ³» ´Ù¸ñÀûÈ­Àå½ÇÀÇ Æò¸éÀ¯Çü°ú °ø°£±¸¼º¿¡ °üÇÑ ¿¬±¸ / A Study on the Floor Plan Types and the Space Composition of Multi-used Toilets InPublic-Toilets of Choongchung-Do
ÀúÀÚ¸í ±èÀºÁß
¹ßÇà»ç Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
¼ö·Ï»çÇ× Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ ³í¹®Áý, v.15 n.1(Åë±Ç 54È£) (2006-02)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(139) ÃÑÆäÀÌÁö(8)
ISSN 12297992
ÁÖÁ¦ºÐ·ù °èȹ¹×¼³°è
ÁÖÁ¦¾î ´Ù¸ñÀûÈ­Àå½Ç ; °øÁßÈ­Àå½Ç ; Æò¸éÀ¯Çü ; °ø°£±¸¼º ; °øÁßÈ­Àå½ÇÇùȸ ¸Å´º¾ó ; Multi-used toilet ; Public toilet ; Floor Plan Types ; Space Composition ; Manual of Institute of Public toilet
¿ä¾à1 º» ¿¬±¸´Â ÃÖ±Ù¿¡ ½ÅÃàµÈ ÃæÃ»Áö¿ªÀÇ °øÁßÈ­Àå½ÇÀ» Áß½ÉÀ¸·Î ´Ù¸ñÀûÈ­Àå½ÇÀÌ °ø°£ »ó¿¡ ¾î¶°ÇÑ ÇüÅ·Π±¸ÃàµÇ¸ç ÀÌ·Î ÀÎÇÑ µ¿¼±ÀÇ ¹®Á¦¸¦ ÆÄ¾ÇÇÏ°í ´Ù¸ñÀûÈ­Àå½ÇÀÇ ³»ºÎ°ø°£ ±¸¼º¿¡ ´ëÇÑ ºÐ¼®À» ÅëÇØ ÇâÈÄ °èȹµÉ °øÁßÈ­Àå½Ç¿¡¼­ÀÇ ´Ù¸ñÀûÈ­Àå½ÇÀÇ °èȹ ½Ã Âø¾È»çÇ×À» Á¦°øÇÔÀ¸·Î¼­ ´Ù¸ñÀûÈ­Àå½ÇÀÇ Àå¼Ò¼ºÀ̳ª ÇÕ¸®Àûµ¿¼± ¹× °ø°£»ç¿ëµîÀÇ È¿À²¼º¿¡ ±â¿©ÇÒ ¼ö ÀÖµµ·ÏÇϰíÀÚ ÇÑ´Ù.
¿ä¾à2 This study shows the floor plan types and the space composition of multi-used toilets in public-toilets of Choongchung-Do. The areas of multi-used toilets are various from 4.8m2 to 10.5m2. And there is usually one multi-used toilet in one public-toilet, but some public-toilets have two multi-used toilets. Multi-used toilets have several equipments such as toilet stool, urinal, washstand, change diaper, chair for baby-care, toilet stool for child, urinal for child, so on. All the multi-used toilets have toilet stool and washstand, but urinal and change diaper were used restrictively, and chair for baby-care, toilet stool for child, urinal for child were used in few cases. There are six types how the multi-used toilets are located in public-toilets, five types of multi-used toilet forms, and five types how the equipments are installed in multi-used toilets. The dotted blocks are installed partially in line type, and partially in spot type. But some cases, there was no installation of dotted block. Auto-sliding door were usually applicated, and some other types of door system were used restrictively. This study offers not only the present conditions, but also the appropriate planning directions of the multi-used toilets.
¼ÒÀåó Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ
¾ð¾î Çѱ¹¾î
ºÐ¼®¼­Áö
°ÇÃà°èȹ ¹× ¼³°è > ºñÁְŰÇÃà °èȹ > ±âŸ

ÀÌ ¿¬±¸´Â ÃÖ±Ù¿¡ ½ÅÃàµÈ ÃæÃ»Áö¿ªÀÇ °øÁßÈ­Àå½ÇÀ» Áß½ÉÀ¸·Î ´Ù¸ñÀûÈ­Àå½ÇÀÌ °ø°£ »ó¿¡ ¾î¶°ÇÑ ÇüÅ·Π±¸ÃàµÇ¸ç ÀÌ·Î ÀÎÇÑ µ¿¼±ÀÇ ¹®Á¦¸¦ ÆÄ¾ÇÇÏ°í ´Ù¸ñÀûÈ­Àå½ÇÀÇ ³»ºÎ°ø°£ ±¸¼º¿¡ ´ëÇÑ ºÐ¼®À» ÅëÇØ ÇâÈÄ °èȹµÉ °øÁßÈ­Àå½Ç¿¡¼­ÀÇ ´Ù¸ñÀûÈ­Àå½ÇÀÇ °èȹ ½Ã Âø¾È»çÇ×À» Á¦°øÇÔÀ¸·Î¼­ ´Ù¸ñÀûÈ­Àå½ÇÀÇ Àå¼Ò¼ºÀ̳ª ÇÕ¸®Àûµ¿¼± ¹× °ø°£»ç¿ëµîÀÇ È¿À²¼º¿¡ ±â¿©ÇϰíÀÚ ÇÏ¿´´Ù.
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
ÇÁ·Î±×·¥°ú ´ÙÀ̾î±×·¥ÀÇ Àû¿ëÀ» ÅëÇÑ °ÇÃà ÇüÅ »ý¼º ¿¬±¸
À±Çý°æ(Yoon Hae-Kyung) ; ±èÁÖ¿µ(Kim Ju-Young) ; È«¿øÈ­(Hong Won-Hwa) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.26 n.02 (201002)
·½ ÄðÇϽº¿Í Ä«Áî¿ä ¼¼Áö¸¶ °ÇÃà¿¡¼­ ³ªÅ¸³ª´Â ÇÁ·Î±×·¥ÀÇ Á¶Á÷°ú °ø°£±¸¼º ¹æ¹ýÀÇ ºñ±³ºÐ¼®
±Ç°æ¹Î ; ±èÁ¾Áø - Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ ³í¹®Áý : v.16 n.6(Åë±Ç 65È£) (200712)
Ãæ³²Áö¿ª °øÁßÈ­Àå½ÇÀÇ Æò¸éÀ¯Çü°ú ½Ã¼³ ÇöȲ¿¡ °üÇÑ ¿¬±¸
±èÀºÁß(Kim Eun-Joong) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.23 n.2 (200702)
[½Ã·Ð] 4Â÷ »ê¾÷Çõ¸í ½Ã´ë, °ÇÃàÀÇ ´ëÀÀ
À̸í½Ä(Lee, Myung-Sik) - °ÇÃà(´ëÇѰÇÃàÇÐȸÁö) : Vol.61 No.05 (201705)
±¹³» ÆÐ½Ãºê°ÇÃ๰ ¼³°è ¹× ½Ã°ø»ç·Ê
À̸íÁÖ - Çѱ¹±×¸°ºôµùÇùÀÇȸ Ãß°èÇмú°­¿¬È¸ ³í¹®Áý : (200911)
[ƯÁý] ģȯ°æ °ÇÃ๰ÀÇ °³³ä ¹× °èȹ ¹æ¹ý
À±Á¾È£ - °ÇÃàȯ°æ¼³ºñ(Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸÁö) : v.1 n.2 (200710)
°ø¿ø ³» °øÁßÈ­Àå½ÇÀÇ Ä£È¯°æ °ÇÃà°èȹ ¹æ¾È¿¡ °üÇÑ ¿¬±¸
¹ÚÇö¼ö(Park Hyeon-Soo) ; ÀÓ¼öÇö(Yim Su-Hyun) ; ÀÌÁö¿µ(Lee Ji-Young) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.27 n.1 (201101)
°ÇÃࡤµµ½Ã°ø°£ÀÇ Çö´ëÀû °ø°ø¼º¿¡ °üÇÑ ±âÃÊ ¿¬±¸
¿°Ã¶È£ ; ½É°æ¹Ì ; Á¶Áعè - ¿¬±¸º¸°í¼­(±âº») : 2008 n.8 (200902)
±×¸®µåü°èÀÇ º¯ÇüÀ» ÅëÇÑ ÇüÅ»ý¼ºÇÁ·Î¼¼½º ¿¬±¸
ÇÑ»ó±æ ; À̰øÈñ - Çѱ¹¹®È­°ø°£°ÇÃàÇÐȸ ³í¹®Áý : Åë±Ç Á¦22È£ (200806)