³í¹®¸í |
´ë±¸Áö¿ª ÁöÇϰø°£ ½Ç³»°ø±âÁú ÃøÁ¤ ¹× Æò°¡¿¡ °üÇÑ ¿¬±¸ / A Study on the Measurement and Evaluation of Indoor Air Quality in Daegu underground space |
ÀúÀÚ¸í |
±èÅ¿ì ; ±èÇöÅ ; ¹ÚÇö½Ä ; È«¿øÈ |
¼ö·Ï»çÇ× |
Çѱ¹»ýÅÂȯ°æ°ÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý, Åë±Ç8È£ (2005-05) |
ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(89) ÃÑÆäÀÌÁö(5) |
ÁÖÁ¦¾î |
ÁöÇÏ¿ª»ç ; ½Ç³»°ø±âÁú ; Èֹ߼ºÀ¯±âÈÇÕ¹° ; Æ÷¸§¾Ëµ¥È÷µå ; Subway station ; Indoor Air Quality ; VOCs ; HCHO |
¿ä¾à1 |
º» ¿¬±¸´Â ´ÙÁßÀÌ¿ë½Ã¼³ Áß ÁöÇϰø°£¿¡ ´ëÇÑ ½Ç³»¿À¿°¿ø ÀÎ ÃÑÈֹ߼ºÀ¯±âÈÇÕ¹° ¹× Æ÷¸§¾Ëµ¥È÷µå ³óµµ¸¦ ÃøÁ¤ÇÏ¿© ½Ç³»°ø±âÁú ºÐ¼®À» À§ÇÑ ±âÃÊ µ¥ÀÌÅ͸¦ ±¸ÃàÇÏ°í ¿À¿° Á¤µµ¸¦ Æò°¡Çغ¸°íÀÚ ÇÑ´Ù. |
¿ä¾à2 |
Many people have lived in indoor space. Indoor air pollution from airtight space has become one of the many problems awaiting solution to human society. Indoor air pollution is caused by TVOCs and HCHO, whose density takes measurement, and this study analyzes an pollution level and a basic data. The results of this study on underground space are as follows: In case of a subway station, TVOCs and HCHO seem to be numerical value both an existing station and a new station. Because building materials get out of a pollutant, pollution value seems to be decreased by ventilation facilities and flue facilities. Although an underground store is also lower pollution value, indoor air quality is polluted by using of adhesives and decorative veneer. The difference of an pollution degree seems to be high in shops. Therefore, there is a need today for measures against this problem. |