³í¹®¸í |
¿ªÁöºØ ³ìÈ¿Á»ó½Ã½ºÅÛ(KICT-GRS2004)ÀÇ ¿ì¼öÀ¯Ãâ Æ¯¼º¿¡ °üÇÑ ½ÇÇèÀû ¿¬±¸ / A Experimental Study on Effluence Characteristic of the Rainfall in the IRMA Green Roof System of KICT |
ÀúÀÚ¸í |
Àå´ëÈñ ; ±èÇö¼ö ; À̰ÇÈ£ ; ¹®¼ö¿µ |
¼ö·Ï»çÇ× |
Çѱ¹»ýÅÂȯ°æ°ÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý, Åë±Ç8È£ (2005-05) |
ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(63) ÃÑÆäÀÌÁö(6) |
ÁÖÁ¦¾î |
¿Á»ó³ìÈ ; ¿Á»ó½Ã°ø ; ¿ªÁöºØ ; µµ½Ã±âÈÄÁ¶Àý ; ¿¼º´É ; green roof ; roof construction ; IRMA ; city-climate-control ; thermal conductivity |
¿ä¾à1 |
º» ¿¬±¸´Â ÇöÀç Çѱ¹°Ç¼³±â¼ú¿¬±¸¿øÀÇ ±âº»¿¬±¸»ç¾÷À¸·Î ÁøÇàÁßÀΡ°Plus50 ȯ°æ°ø»ýºôµù Á¶¼º ±â¼ú °³¹ß¡±ÀÇ ¼¼ºÎ°úÁ¦ Áß ÇϳªÀΡ°º¹ÇÕ±â´É »ýÅÂÀû °Ç¹°¿ÜÇÇ Á¶¼º ±â¼ú °³¹ß¡±ÀÇ ÀÏȯÀ¸·Î ÀÌ·ç¾îÁø ¿¬±¸ ³»¿ëÀÇ ÀϺÎÀ̸ç, ƯÈ÷ À¯·´°ú ¹ÌÁÖÀÇ ½Ã°øÇöÀå¿¡¼ ±â»óº¯È¿¡ ¹Î°¨ÇÑ ¿Á»óºÎ°ø»çÀÇ ¾àÁ¡À» °³¼±ÇÏ¸é¼ ÇÕ¸®ÀûÀÎ ½Ã°øÀ¸·Î ÀÎÇÑ °ø±â´ÜÃà°ú ³»±¸¼º Çâ»ó¿¡ ÀÇÇÑ ¼ö¸í¿¬Àå µîÀ¸·Î °æÁ¦¼º ¶ÇÇÑ ÀÔÁõµÇ¾î °¡Àå ³Î¸® ÀÚ¸® Àâ°í ÀÖ´Â ¿ªÁöºØ ³ìÈ¿Á»ó(IRMA GRS. : Insulated Roof Membrane Assembly Green Roof System)ÀÇ ±¹³»Àû Çö½Ç Àû¿ë ¹æ¾ÈÀ» ¸ñÇ¥·Î °³¹ßµÈ KICT- GRS2004 Prototype °³¹ß¹æÇâ°ú À̸¦ Ȱ¿ëÇÑ ³ìÈ¿Á»óÀÇ ¿ì¼öÀ¯Ãâ Æ¯¼ºÀ» ºÐ¼®ÇϰíÀÚ ÇÏ¿´´Ù. ÀÌ ½Ã½ºÅÛÀº Àå±âÀûÀ¸·Î ±¹³»¿¡¼µµ ¼±ÁøÀû ¿Á»ó³ìȰø¹ýÀ¸·Î¼ ÇâÈÄ¿¡ ÀÚ¸®Àâ°Ô µÉ °ÍÀ̶ó´Â Àü¸Á¾Æ·¡ °¡´ÉÇÑ ±¹³»ÀÇ ±âÈÄÀû ±×¸®°í ½Ã°øÇöÀåÀÇ ¿©°ÇÀ» °í·ÁÇÏ¿© Çѱ¹Àû Çö½Ç¿¡ ÀûÇÕÇÑ °ø¹ýÀ¸·Î °³¹ßÇÏ¿© ¿ªÁöºØ ³ìÈ¿Á»ó½Ã½ºÅÛÀ» Ȱ¼ºÈÇϱâ À§ÇÔÀ̸ç, ÀÌ¿Í ÇÔ²² ½Ã½ºÅÛÀÇ Àû¿ë¿¡ µû¸¥ ¿ì¼öÀ¯Ãâ Æ¯¼ºÀ» ºÐ¼®ÇÔÀ¸·Î¼ ±Ã±ØÀûÀ¸·Î ¿Á»ó³ìȰ¡ µµ½Ã¹Ì±âÈÄÁ¶ÀýÀ̳ª È«¼ö¾ïÁ¦±â´ÉÀÇ Â÷¿ø¿¡¼ ¾î¶°ÇÑ È¿°ú¸¦ Áö´Ï°í ÀÖ´ÂÁö º¸´Ù ÃÑüÀûÀÎ °üÁ¡¿¡¼ »ìÆìº¼ ¼ö ÀÖ´Â ¹æ¹ý·Ð°ú °á°úÄ¡¸¦ Á¦½ÃÇϰíÀÚ ÇÑ´Ù. |
¿ä¾à2 |
The Purpose of this study is development and analysis of Effluence Characteristic of the Rainfall in the IRMA Green Roof System(developed in KICT) Generally, a Green Roof System has a positive effect on the thermal conductivity in winter, the micro cooling effect on building and city by evaporation in summer, the flood-control effect by runoff-reduction or the treated rainwater-quality of green roof system and so on. However, inspection of the physical effect of green roof system does not consider in Korea. Above all, long-term monitoring and a whole observation of green roof system is needed to probate the effect. So a new experimental method could be tried in this research, which is never attempted in Korea. The measurement by a bucket with a great volume, 1L, gives a new dimension of measuring green roof effect to measure the permanent running flood from a wide roof. This offers a reasonable result on a long-term measuring of a running water. Additionally, the thermal behavior of the IRMA(Insulated Roof Membrane Assembly), known in the western europe as a reasonable solution at green roof system by economical benefits and easy construction, would be experimented. |