³í¹®¸í |
´Ü¿ ½ºÆäÀ̼ Àû¿ë¿¡ µû¸¥ âȣ½Ã½ºÅÛÀÇ Ç¥¸é°á·Î ¹æÁö¼º´É Æò°¡ / Evaluation of Inside Surface Condensation on the Window System with Insulation Spacer |
ÀúÀÚ¸í |
ÁÖ¼±°æ (Chu Seon-Kyung) ; ¼Û½Â¿µ (Song Seung-Yeong) |
¼ö·Ï»çÇ× |
´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý °èȹ°è, v.20 n.10 (2004-10) |
ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(311) ÃÑÆäÀÌÁö(8) |
ÁÖÁ¦¾î |
âȣ½Ã½ºÅÛ ; ½Ç³»Ãø Ç¥¸é°á·Î ; ´Ü¿ ½ºÆäÀ̼ ; Window System ; Inside Surface Condensation ; Insulation Spacer |
¿ä¾à1 |
ÃÖ±Ù ±¹³»¿¡¼´Â âȣ½Ã½ºÅÛ °ü·Ã ±â¼úÀÇ ¹ßÀü°ú ´õºÒ¾î ¿¡³ÊÁö Àý¾à¿¡ ´ëÇÑ Ãß¼¼¸¦ ¹Ý¿µ, »ó¾÷¿ë °Ç¹°Àº ¹°·Ð ÁÖ°Å¿ë °Ç¹°¿¡µµ ¿È¿À²À» ³ôÀ̱â À§ÇÑ º¹ÃþÀ¯¸®ÀÇ Àû¿ëÀÌ º¸ÆíȵǾú´Ù.??ÀÌ´Â °Ç¹° Àüü ¼Õ½Ç¿·®ÀÇ 20¢¦40%¸¦ Â÷ÁöÇϴ âȣ½Ã½ºÅÛÀÇ ´Ü¿¼º´É Çâ»óÀ» À§ÇÑ °ÍÀ̶ó°í ÇÒ ¼ö ÀÖ´Ù. ??º¹ÃþÀ¯¸®¸¦ Àû¿ëÇÑ Ã¢È£½Ã½ºÅÛÀÇ ´Ü¿¼º´ÉÀº À¯¸® Á¾·ù³ª ÇÁ·¹ÀÓ, ½ºÆäÀ̼ µî ±âŸ ºÎÀÚÀçÀÇ ¼º´É µî¿¡ ÀÇÇØ Å« ¿µÇâÀ» ¹Þ°Ô µÈ´Ù.??ÃÖ±Ù Áö¾îÁö°í ÀÖ´Â °Ç¹°¿¡´Â À¯¸® Á¾·ù·Î Low-E ±Û¶ó½º¸¦ Àû¿ëÇϱ⵵ ÇÏ°í, ÇÁ·¹ÀÓ¿¡´Â Æú¸®¾Æ¹Ìµå³ª ¾ÆÁ¸ µîÀÇ Thermal Breaker¸¦ ´ëºÎºÐ »ðÀÔÇÏ´Â µî º¹ÃþÀ¯¸®¸¦ Àû¿ëÇÑ Ã¢È£½Ã½ºÅÛÀÇ ´Ü¿¼º´ÉÀº »ó´ç ºÎºÐ Çâ»óµÇ¾ú´Ù°í ÇÒ ¼ö ÀÖ´Ù. ??±×·¯³ª ÇöÀç º¹ÃþÀ¯¸®¿¡¼ Áß°øÃþÀ» Çü¼º, À¯ÁöÇϱâ À§ÇØ À¯¸®¿Í ÇÁ·¹ÀÓÀÌ ¸¸³ª´Â ÁöÁ¡ÀÇ À¯¸®»çÀÌ¿¡ »ðÀÔÇÏ´Â ¾Ë·ç¹Ì´½ ÀçÁúÀÇ ½ºÆäÀ̼´Â °ß°íÇÔ¿¡ ÀÖ¾î ÃæºÐÈ÷ ±× ¼º´ÉÀ» ¸¸Á·½ÃÅ°°í ÀÖÁö¸¸, ¾Ë·ç¹Ì´½ °íÀ¯ÀÇ Æ¯¼ºÀÎ ³ôÀº ¿ÀüµµÀ²·Î ÀÎÇØ ¿©ÀüÈ÷ ¿±³ºÎÀ§°¡ µÇ°í ÀÖ´Ù.??ÀÌ·Î ÀÎÇØ ¾Ë·ç¹Ì´½ ½ºÆäÀ̼¸¦ ÅëÇÑ ¿¼Õ½ÇÀÌ Ã¢È£½Ã½ºÅÛ Àüü ¿¼Õ½ÇÀÇ »ó´ç ºÎºÐÀ» Â÷ÁöÇÏ°í ÀÖÀ¸¸ç, µ¿°è ½Ç³»Ãø Ç¥¸é¿ÂµµÀÇ ÀúÇϸ¦ À¯¹ßÇÏ¿© °á·Î¸¦ ¹ß»ý½ÃÅ°´Â µî ¸¹Àº ¹®Á¦¸¦ ¾ß±âÇÏ°í ÀÖ´Ù.??ÀÌ´Â µ¿°è âȣ½Ã½ºÅÛ¿¡¼ À¯¸®¿Í ÇÁ·¹ÀÓÀÌ ¸¸³ª´Â À¯¸®ÀÇ °¡ÀåÀÚ¸®ºÎÅÍ °á·Î°¡ ¹ß»ýÇϱ⠽ÃÀÛÇÏ´Â Çö»óÀ» ÅëÇØ ½±°Ô È®ÀÎÇÒ ¼ö ÀÖ´Ù.??ÀÌ·¯ÇÑ °á·ÎÇö»óÀº Ç°Áú ÀúÇÏ ¹× ÁÖÀ§ ³»ÀåÀçÀÇ ¼Õ»ó°ú ½ÉÇÑ °æ¿ì ±×¸² 1°ú °°Àº °áºùÇö»óÀ» À¯¹ßÇÒ ¼öµµ ÀÖÀ¸¹Ç·Î ¹æÁöµÇ¾î¾ß ÇÑ´Ù. ??µû¶ó¼ º» ¿¬±¸¿¡¼´Â ¾Ë·ç¹Ì´½ ½ºÆäÀ̼¸¦ ´ëü °¡´ÉÇÑ ´Ü¿ ½ºÆäÀ̼¿¡ ´ëÇØ ÆľÇÇÑ ÈÄ, âȣ½Ã½ºÅÛ¿¡¼ÀÇ Ç¥¸é°á·Î ¹æÁö¼º´É¿¡ °üÇÑ Æò°¡¹æ¹ýÀ» ¼³Á¤ÇÏ¿´´Ù.??±×¸®°í ÇöÀç ½Ã°øÁßÀÎ ºÎ»ê¼ÒÀç AÁÖ»óº¹Çհǹ°ÀÇ ¼ö¿µÀå ¹× ÁְźΠâȣ½Ã½ºÅÛÀ» ´ë»óÀ¸·Î ´Ü¿ ½ºÆäÀ̼ Àû¿ë ÀüÈÄÀÇ Ç¥¸é°á·Î ¹æÁö¼º´ÉÀ» Æò°¡, ºÐ¼®ÇÔÀ¸·Î½á º¹ÃþÀ¯¸®¸¦ Àû¿ëÇÑ Ã¢È£½Ã½ºÅÛÀÇ Ç¥¸é°á·Î ¹æÁö¼º´ÉÀ» Çâ»ó½ÃÅ°°íÀÚ ÇÏ¿´´Ù. |
¿ä¾à2 |
Double glazed window system has been commonly used in buildings of today due to energy issue.?? Insulation performance of double glazed window system is influenced by many factors such as glass type, thermal breaker in frame, spacer and so on.??In buildings constructed recently, there have been many cases to improve the insulation performance of double glazed window system by using the low-e glass and thermal breaker made of poly-amide or azon.??However aluminum spacer still becomes a thermal bridge at which the heat loss and risk of inside surface condensation increase due to its high thermal conductivity.??As inside surface condensation may cause many problems, it should be prevented. ??Thus this study aims to evaluate the surface condensation on the double glazed window system with insulation spacer made of FRP(Fiber Reinforced Plastic).??Window systems of both swimming pool and residential unit in A residential complex located in Pusan are made the target of evaluation.??The lowest inside surface temperature is calculated by the two dimensional steady state heat transfer simulation.??It is determined whether the inside surface condensation may or may not occur under the vario |