¿ÜÁ¶±â¿¡ ÀÇÇÑ Æ丮¹ÌÅÍÁ¸ÀÇ °ø±âÁ¶È½Ã½ºÅÛ¿¡ °üÇÑ ¿¬±¸ / A Study on the Air Conditioning System of the Perimeter Zone with the Outdoor Fresh Air Conditioner |
¼ö·Ï»çÇ× |
´ëÇÑ°ÇÃàÇÐȸ³í¹®Áý °èȹ°è, v.14 n.10 (1998-10) |
ÆäÀÌÁö |
½ÃÀÛÆäÀÌÁö(211) ÃÑÆäÀÌÁö(8) |
¿ä¾à1 |
»ç¹«¼Ò¿¡ ±Ù¹«ÇÏ´Â Àç½ÇÀÚµéÀÇ È¯°æ¿ä±¸¼öÁØÀÌ Á¡Á¡ ³ô¾ÆÁ® °¡°í ÀÖÀ¸¸ç ±× Áß¿¡¼µµ Æ丮¹ÌÅÍÁ¸¿¡ ÀÖ¾î¼ÀÇ ½Ç³»È¯°æ¹®Á¦¿¡ ´ëÇÑ °ü½ÉÀÌ Å©Áö°í ÀÖ´Ù. Æ丮¹ÌÅÍÁ¸ °øÁ¶ºÎÇÏ󸮽ýºÅÛÀ¸·Î´Â ÀϹÝÀûÀ¸·Î FCU½Ã½ºÅÛÀÌ ¸¹ ÀÌ Ã¤¿ëµÇ°í ÀÖÀ¸³ª Æ丮¹ÌÅÍÁ¸¿¡¼ÀÇ °ÅÁÖȯ°æÀÇ Ãë¾à, IBS¼³°è¿¡ ÀÖ¾î¼ ÀÇ ¼ö¹è°ü°ú ´©¼öÀ§Ç輺, FCU°ø°£»çÀÌ¿¡¼ ¹ß»ýÇÏ´Â Äݵåµå·¹ÇÁÆ®(cold draft)Çö»ó, À¯´ÏÆ®Á¦¾î¼º´ÉÀÇ ÀúÇÏ, ÀÎÅ׸®¾îÁ¸°úÀÇ È¥ÇÕ¼Õ½Ç, â¸éÀÇ °á·Î Çö»óµîÀÌ ÁöÀûµÇ°í ÀÖ´Ù. ÀÌ¿Í °°Àº Ãø¸é¿¡¼ ¿ÜÁ¶±â¿¡ ÀÇÇÑ Ã¢ÇϺÎÈíÀԽà ½ºÅÛ¿¡ ÀÖ¾î¼ ÃëÃⱸÇü»ó, â¸é¿¡¼ ¹ß»ýÇÏ´Â Äݵåµå·¹ÇÁÆ®, Æ丮¹ÌÅÍÁ¸ÀÇ ½Ç³»È¯°æ, °á·Î»óÅÂ, ½Ã½ºÅÛÀÇ ¿¡³ÊÁöÀý¾àµîÀ» »ìÆ캸¾Ò´Ù. ¿¬±¸°á°ú¿¡ ÀÇ Çϸé ÀÌ·¯ÇÑ ¹®Á¦Á¡ÀÌ °ÅÀÇ ÇØ°á°¡´ÉÇÔÀÌ °ËÁõµÇ¾úÀ¸¸ç, º» ½Ã½ºÅÛ¼³°èÀÇ ½Ç¿ëȸ¦ ±¸ÃàÇϴµ¥ ÇÊ¿äÇÑ µ¥ÀÌÅ͸¦ µµÃâÇÏ¿´´Ù. º» ½Ã½ºÅÛÀº ³¹æÃëÃ⠿µµ¸¦ ½Ç³»¼³°è¿Âµµº¸´Ù ³·°Ô ¼ÛdzÇÔÀ¸·Î½á ¿Â¿¿ø¿ë·®ÀÇ °¨¼Ò, ÈíÀÔ°ø±â ¸¦ ÀÎÅ׸®¾îÁ¸À¸·Î ¼ÛdzÇÔÀ¸·Î½á ³Ã¿¿ø¿ë·®ÀÇ °¨¼Ò, µ¿±âÆ丮¹ÌÅÍÁ¸ÀÇ Ç³ ·®ÀÌ ÃּҿܱⷮÀ¸·Î ´ëÀÀ°¡´ÉÇÔÀ¸·Î½á ¹Ý¼Ûµ¿·ÂÀÇ Àý¾à, Æ丮¹ÌÅͺÎÇÏ¿¡ ´ëÀÀÇÏ¿© ¼Ûdz·®À» Á¦¾îÇÔÀ¸·Î½á ÇϱâÀÇ ¹Ý¼Ûµ¿·ÂÀý¾àµîÀÇ ¿¡³ÊÁöÀý¾àÈ¿°ú µµ ±â´ëÇÒ ¼ö ÀÖ¾î Æ丮¹ÌÅÍÁ¸ÀÇ ¿Ã³¸®½Ã½ºÅÛÀ¸·Î À¯È¿Çϸ®¶ó »ý°¢µÈ´Ù. º» ¿¬±¸¿¡¼ÀÇ ½ÇÇèÁ¶°ÇÀº ÀϺ»µ¿°æÁö¿ªÀ» »óÁ¤ÇÏ¿© ¼öÇàµÇ¾îÁø °ÍÀ̹ǷΠ¿©±â¿¡¼ ¾ò¾îÁø °á°ú¸¦ Àû¿ëÇÔ¿¡ À־ ±× Áö¿ªÀÇ ¼³°è¿Ü±âÁ¶°Çµî¿¡ ´ëÇÑ °ËÅä°¡ ÇÊ¿äÇÏ´Ù. Çѱ¹ÀÇ °æ¿ì´Â ¿Ü±âÀÇ ¼öºÐÇÔÀ¯·®ÀÌ ºñ±³Àû ³·À» »Ó ¾Æ´Ï¶ó Æä¾î±Û·¡½ºÃ¤¿ëÀÌ °ÅÀÇ ÀϹÝȵǾî ÀÖ´Â »óȲ¿¡¼ º»´Ù¸é, ÃëÃâ dz·®°ú ³Ã°¢¿·®À» °¨¼Ò½Ãų ¼ö ÀÖÀ¸¹Ç·Î º» ½Ã½ºÅÛÀÇ ¼³°è¹æ¹ý·ÐÀ» À¯¸® ÇÏ°Ô ÀÀ¿ëÇÒ ¼ö ÀÖÀ¸¸®¶ó »ý°¢µÈ´Ù. |
¿ä¾à2 |
The objective of is to the of thermal environment in the perimeter zone with the outdoor fresh air conditioner in office buildings. The system consists of a line diffuser on ceiling, an insulated suction chamber below the window, the fresh air conditioner for perimeter heating load and the interior air conditioner for interior cooling load. Experiments have been carried out by the environmental chamber designed to control artificially air conditioning parameters. The result of this st udy, obtained from the Parametric experimental test for the optimum air conditioning system to pre-vent the cold draft and condensation on windowpane, has shown that the most efficient and suitable conditions are as foll-ows:1)Diffusing air temperature :17'C 2)The distance of diffuser from the windowpane 100mm 3)The suction chamber from the windowpane:350mm 4)Return air volumn for design: 120 ¡ 125C MH/m 5)The distribution of vertical temperature has been within 1.5 between 1800mm and 50mm point above floor level in the perimeter zone 6)The cold radiation effect zone: about 1500mm from win- dowpane |