°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > Àú³Î > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 50 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â

Çѱ¹±¸Á¶¹°Áø´ÜÀ¯Áö°ü¸®°øÇÐȸ|³í¹®Áý 2025³â 10¿ù

±â»ç¸í ÇÁ¸®Ä³½ºÆ® ½½·¡ºê¿¡¼­ 180µµ °¥°í¸® ö±Ù °ãħÀÌÀ½ÀÇ °Åµ¿¿¡ ´ëÇÑ ½ÇÇèÀû ¿¬±¸ / Experimental Study on the Behavior of 180¡Æ Hooked Bar Lap Splices in Precast Slabs
ÀúÀÚ¸í À̹®¼®(Moon-Seok Lee) ; ÃÖâ½Ä(Chang-Sik Choi) ; ¹è¹éÀÏ(Baek-Il Bae)
¹ßÇà»ç Çѱ¹±¸Á¶¹°Áø´ÜÀ¯Áö°ü¸®°øÇÐȸ
¼ö·Ï»çÇ× Çѱ¹±¸Á¶¹°Áø´ÜÀ¯Áö°ü¸®°øÇÐȸ ³í¹®Áý , Vol.29 No.5(2025-10)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(149) ÃÑÆäÀÌÁö(8)
ISSN 2234-6937
ÁÖÁ¦ºÐ·ù
ÁÖÁ¦¾î 180¡Æ °¥°í¸® ö±Ù; °ãħÀÌÀ½±æÀÌ; ÇÁ¸®Ä³½ºÆ® ÄÜÅ©¸®Æ® ; 180¡Æ hooked reinforcing bar; Lap splice length; Precast concrete
¿ä¾à1 º» ¿¬±¸´Â ÇÁ¸®Ä³½ºÆ® ÄÜÅ©¸®Æ® ±¸Á¶¿¡¼­ °¥°í¸® ö±ÙÀº Á÷¼±¿¡ ºñÇØ ªÀº ÀÌÀ½±æÀ̷εµ ÃæºÐÇÑ Á¤Âø¼º´ÉÀ» È®º¸ÇÒ ¼ö ÀÖ¾î ½Ã°ø¼º°ú °æÁ¦¼ºÀ» ³ôÀÏ ¼ö ÀÖ´Â ´ë¾ÈÀ¸·Î ÁÖ¸ñ¹Þ°í ÀÖ´Ù. PC ºÎÀç°£ ÀÌÀ½±æÀ̸¦ »êÁ¤ÇÒ ¶§ ÇöÇ༳°è±âÁØÀÇ °¥°í¸® ö±ÙÀÇ Á¤Âø±æÀÌ »êÁ¤½ÄÀº º¸- ±âµÕ Á¢ÇպΠ½ÇÇèÀ» ¹ÙÅÁÀ¸·Î µµÃâµÈ °ÍÀ¸·Î, °¥°í¸® ö±ÙÀ» ÀÌ¿ëÇÑ °ãħÀÌÀ½¿¡ Á÷Á¢ Àû¿ëÇϱ⿡´Â ÇѰ谡 ÀÖ´Ù. ÇÁ¸®Ä³½ºÆ® ½½·¡ºê¿¡¼­ »ç¿ëµÇ´Â 180µµ °¥°í¸® ö±ÙÀÇ °ãħÀÌÀ½ÀÇ °Åµ¿¿¡ ´ëÇÑ ½ÇÇèÀ» ¼öÇàÇÏ¿´´Ù. ÃÑ 10°³ÀÇ ½ÇÇèü¸¦ 4Á¡ ÈÚ½ÇÇèÀ» ¼öÇàÇÏ¿´°í Á¤Âø±æÀÌ ¼³°èÀÎÀÚ(ÄÜÅ©¸®Æ® ¾ÐÃà°­µµ ö±ÙÀÇ Ç׺¹°­µµ, Á¤Âø±æÀÌ)¸¦ º¯¼ö·Î ÇÏ¿´´Ù. ½ÇÇè°á°ú, ÀÌÀ½±æÀÌÀÇ Áõ°¡´Â ö±Ù¿¡ Àü´ÞÇÒ ¼ö ÀÖ´Â ÀÀ·ÂÀÇ Å©±â¸¦ ¼±ÇüÀûÀ¸·ÎÁõ°¡½ÃŰ´Â °ÍÀ¸·Î ³ªÅ¸³µÀ¸¸ç, ªÀº ÀÌÀ½±æÀ̸¦ °¡Áø ½ÇÇèü¿¡¼­´Â Âɰ·ÆÄ±« ¹× ÇÁ¶óÀ× °Åµ¿ µî Ã뼺ÀûÀÎ ÆÄ±«°¡ ¹ß»ýÇÏ¿´´Ù. ¸ð¸àÆ® °î·ü ´Ü¸éÇØ¼®À» ÅëÇØ ÇöÇà ¼³°è±âÁذú ºñ±³Æò°¡ÇÏ¿´À¸¸ç, Á¤Âø±æÀÌ »êÁ¤½ÄÀÌ ½ÇÇè°á°ú¸¦ 1.03À¸·Î Àß ¿¹ÃøÇϰí ÀÖ´Â °ÍÀ» È®ÀÎÇß´Ù. ÃßÈÄ ¿¬±¸¸¦ ÅëÇØ Ⱦº¸°­±Ù ¹× ÇǺ¹µÎ²²µî ´Ù¾çÇÑ ¼³°èÀÎÀÚÀÇ Æò°¡°¡ ÇÊ¿äÇϸç, ö±ÙÀÇ Ç׺¹À» À§ÇÑ °ãħÀÌÀ½±æÀÌ¿¡ ´ëÇÑ Á¶»ç°¡ ÇÊ¿äÇÏ´Ù.
¿ä¾à2 In precast concrete (PC) structures, hooked bars have attracted attention as an alternative to straight bars, as they can achieve sufficient anchorage performance with shorter lap lengths, thereby improving constructability and cost efficiency. When determining lap lengths between PC members, the development length equations for hooked bars specified in current design codes (ACI 318-25, KDS 14 20 52) are derived from beam? column joint tests, and thus their direct applicability to hooked bar lap splices is limited. This study experimentally investigates the performance of 180¡Æ hooked bar lap splices by testing 10 precast slab specimens under four-point bending.
The key variables considered were splice length, bar diameter, concrete compressive strength, and yield strength of reinforcement, which were determined based on the ACI 318-25 hooked bar development length equation. Splice lengths were set to 0.3?1.0 times the code-based development length to examine the effective lap length of hooked bars required in practice. Test results indicated that the bar stresses measured in spliced specimens were 1.07?1.08 times greater than the stresses predicted by the KDS 14 20 52 equations, suggesting that the current provisions can be reasonably applied to estimate lap splice lengths of 180¡Æ hooked bars.
¼ÒÀåó Çѱ¹±¸Á¶¹°Áø´ÜÀ¯Áö°ü¸®°øÇÐȸ
¾ð¾î Çѱ¹¾î
DOI https://doi.org/10.11112/jksmi.2025.29.5.149