Çѱ¹ÀǷẹÁö°ÇÃàÇÐȸ|ÀǷᡤº¹Áö °ÇÃà(Çѱ¹ÀǷẹÁö°ÇÃàÇÐȸÁö) 2009³â 2¿ù

±â»ç¸í [³í¹®] ³ëÀοä¾ç½Ã¼³ Çdz­°èȹ Á¦µµÀû °³¼±¹æ¾È ¿¬±¸ / A Study on the Reform of the Evacuation Planning in the Nursing home for the Elderly
ÀúÀÚ¸í ±èÀ±Á¤ ; ±è¼®Áؽĺ°ÀúÀÚ ; À±¸í¿À
¹ßÇà»ç Çѱ¹ÀǷẹÁö½Ã¼³ÇÐȸ
¼ö·Ï»çÇ× Çѱ¹ÀǷẹÁö½Ã¼³ÇÐȸÁö , v.15 n.1(Åë±Ç 34È£)(2009-02)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(13) ÃÑÆäÀÌÁö(10)
ISSN 12260762
ÁÖÁ¦ºÐ·ù °èȹ¹×¼³°è
ÁÖÁ¦¾î Çdz­°èȹ ; ³ëÀοä¾ç½Ã¼³ ; ³ëÀ¯Àڽü³ ; °ÇÃà¹æÀç ; ¹æÀç°èȹ ; Evacuation Planning ; Nursing home for the elderly ; Fire Protection of Building ; Fire Protection Planing
¿ä¾à2 The nursing home for the elderly has a weak point for evacuation from the fire because most of all the users are suffering from a dementia or paralysis. When it comes to night shift, it is much difficult to get them evacuated due to the lack of staffs. In addition to that, the nursing home for the elderly has such a strict control system for access that does not have a utility for escape opening. That is why they need the differentiated evacuation planning. This study is to consider the point at issues on the present conditions of law, system, and evacuation plans for the nursing home for the elderly that has some difficulties because of impaired functions of residences. This study dealt with the point at facilities and operations of the emergency evacuation system. First of all, for the point at the facilities, I found that it need to be considered on the characteristics of the elderly who has any difficulties of the self evacuation. And the established regulation did not reflect the characteristics of closed area of the nursing home for the elderly. The second, for the point at the operation of the institutions, it is pointed that there seems to be a lack of ways to manage to a emergency situation and educations on the operation staff. And the last, for the point at the operation, the requirement for the managers of fire prevention facilities are similar to that of a normal building. Furthermore there is a lack of corporation with the fire station.
¼ÒÀåó Çѱ¹ÀǷẹÁö½Ã¼³ÇÐȸ
¾ð¾î Çѱ¹¾î
¡á Ãßõ¹®Çå (ÀÌ ¹®Çå°ú °°ÀÌ º» ¹®Çå)
[½Ã·Ð] 4Â÷ »ê¾÷Çõ¸í ½Ã´ë, °ÇÃàÀÇ ´ëÀÀ
À̸í½Ä(Lee, Myung-Sik) - °ÇÃà(´ëÇѰÇÃàÇÐȸÁö) : Vol.61 No.05 (201705)
³ëÀνü³ÀÇ Çdz­ÇàÅ ºÐ¼®À» ÅëÇÑ °ÇÃà°èȹ ¹× ¿î¿µ°ü¸® Áöħ¿¡ °üÇÑ ¿¬±¸
ÀÌÁ¤¼ö(Lee Jeong-Soo) ; ±èÀÀ½Ä(Kim Eung-Sik) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.20 n.6 (200406)
Çѱ¹ ³ëÀοä¾ç½Ã¼³ÀÇ À¯Çü, À§Ä¡, ÁÖº¯È¯°æ¿¡ µû¸¥ °ÇÃàÆ¯¼º ºñ±³
º¯Çý·É(Byun Hea-Ryung) ; À±¿µ¼±(Yoon Young-Sun) ; ±è´ë³â(Kim Dae-Nyun) ; Á¤¹Ì·Å(Chung Mi-Ryum) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.24 n.11 (200811)
·½ ÄðÇϽº¿Í Ä«Áî¿ä ¼¼Áö¸¶ °ÇÃà¿¡¼­ ³ªÅ¸³ª´Â ÇÁ·Î±×·¥ÀÇ Á¶Á÷°ú °ø°£±¸¼º ¹æ¹ýÀÇ ºñ±³ºÐ¼®
±Ç°æ¹Î ; ±èÁ¾Áø - Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ ³í¹®Áý : v.16 n.6(Åë±Ç 65È£) (200712)
[³í¹®] ³ëÀÎÀü¹®º´¿øÀÇ °³³ä¼³Á¤ ¹× °ÇÃà°èȹ¹æÇâ¿¡ ´ëÇÑ ¿¬±¸
±Ç¼øÁ¤ - Çѱ¹ÀǷẹÁö½Ã¼³ÇÐȸÁö : v.15 n.1(Åë±Ç 34È£) (200902)
[ƯÁý] ±¹³» ģȯ°æ °ÇÃ๰ »ç·Ê ºÐ¼®
Á¤Áö³ª ; ±è¿ë¼® ; À̽¹Π- ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.9 n.1 (200803)
³ëÀοä¾ç½Ã¼³ÀÇ °ÇÃàÇöȲ ¹× °³¼±¹æÇâ¿¡ °üÇÑ ¿¬±¸
ÀÌ¿Ï°Ç - Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ ³í¹®Áý : v.19 n.3(Åë±Ç 80È£) (201006)
³ëÀοä¾ç½Ã¼³ °ø¿ë°ø°£ÀÇ ÀÚ¿¬¿ä¼Ò µµÀÔ¿¡ °üÇÑ ¿¬±¸
Àü¸í¼÷ ; ÃÖ»óÇå - Çѱ¹½Ç³»µðÀÚÀÎÇÐȸ ³í¹®Áý : v.18 n.1(Åë±Ç 72È£) (200902)
ÀϺ» Ä¡¸Å¿ä¾ç¼ÒÀÇ °ÇÃàÀû Ư¼º°ú °æÇâ
Á¶¿µÇà(Cho Young-Hang) ; ·ùÁ¾¿ì(Lyou Joung-Woo) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.21 n.12 (200512)
ÀϺ» ³ëÀοä¾ç½Ã¼³ÀÇ °ÅÁÖȯ°æÆ¯¼º¿¡ °üÇÑ °íÂû
±è¼±ÅÂ(Kim Sun-Tae) ; À±¿µ¼±(Yoon Young-Sun) ; ±è´ë³â(Kim Dae-Nyun) ; º¯Çý·É(Byun Hea-Ryung) ; Á¤¹Ì·Å(Chung Mi-Ryum) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.24 n.10 (200810)