°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > Àú³Î > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 50 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â

Çѱ¹»ýȰȯ°æÇÐȸ|Çѱ¹»ýȰȯ°æÇÐȸÁö 2003³â 9¿ù

±â»ç¸í [¿¬±¸³í¹®] ¿Âµ¹¹Ù´ÚÀÇ ÇÕÆÇ¸¶°¨ µÎ²²¿Í ÀÎüÀÇ ¿Â¿­»ý¸®¹ÝÀÀ ºñ±³ / A Comparison of Thermo-Physiological Responses of Human Body by Thickness Variations of Plywood Covering on ONDOL System
ÀúÀÚ¸í ¼Û±¹¼·½Äº°ÀúÀÚ
¹ßÇà»ç Çѱ¹»ýȰȯ°æÇÐȸ
¼ö·Ï»çÇ× Çѱ¹»ýȰȯ°æÇÐȸÁö , v.10 n.3(2003-09)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(169) ÃÑÆäÀÌÁö(7)
ISSN 1226-1289
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î ; Skin temperature ; ONDOL ; Floor covering ; Thermal comfort
¿ä¾à1 °ú°ÅÀÇ ¿¬±¸¸¦ Á¾ÇÕÇϸé, ³ª¹«³ª ÄÝÅ©Àç·Î°¡ °¡Àå ?Àº ÄèÀû¿Âµµ¹üÀ§¸¦ °¡Áö´Â °ÍÀ¸·Î Æò°¡µÇ´Âµ¥ °¢ Àç·áÀÇ µÎ²²¿¡ µû¸¥ ÀÎüÀÇ ¿Â¿­¹ÝÀÀ º¯È­¿¡ ´ëÇÏ¿© Á¶»ç¿ÜÁö´Â ¸øÇÏ¿´´Ù. ¿ì¸®³ª¶ó¿¡¼­´Â ÃÖ±Ù¿¡ ¿Âµ¹¹Ù´ÚÀÇ ¸¶°¨Àç·á°¡ Á¾ÀÌÀåÆÇÀ̳ª ºñ´ÒÀåÆÇ¿¡¼­ ³ª¹« ÈǷθµÀ¸·Î ±Þ°ÝÈ÷ ±³Ã¼µÇ°í ÀÖ´Â ÇüÆíÀÌ´Ù. ±×·¯³ª ³ª¹« ¸¶°¨ÀÇ µÎ²²°¡ Á¾ÀÌó·³ ¾ãÀº °æ¿ì¿¡´Â ³ª¹«ÀÇ Æ¯¼ºÀº ¾ø¾îÁø´Ù. ³ª¹«ÀÇ µÎ²²¿¡ µû¸¥ ÀÎüÀÇ ¿Â¿­¹ÝÀÀ¿¡ ´ëÇÑ Á¶»ç´Â ¾ÆÁ÷ ÀÌ·ç¾îÁöÁö ¾Ê¾Ò±â¶§¹®¿¡ º» ¿¬±¸¸¦ ¼öÇàÇÏ°Ô µÇ¾ú´Ù. º» ¿¬±¸ÀÇ ¸ñÀûÀº ¿Âµ¹¹Ù´ÚÀÇ ³ª¹«¸¶°¨ µÎ²²¿¡ µû¸¥ ÀÎüÀÇ ¿Â¿­ »ý¸®¹ÝÀÀÀ» Á¶»çÇÏ¿© ¹Ù´Ú¸¶°¨¼³°è¿¡ ÀÌ¿ëÇÒ ¼öÀÖ´Â ±âÃÊÀڷḦ Á¦°øÇÏ´Â °ÍÀÌ´Ù.
¿ä¾à2 This study aimed to investigate the thermo-physiological responses of healthy subjects who sit on the plywood covering of floor heating system, ONDOL. Environmental chambers were constructed for this study, wherein ambient temperature, and wall and ceiling surface temperature were controlled at 24oC, and relative humidity was at 50%. The temperature of supply water (tsw) flowing into the floor coil was altered from 15oC to 40oC at 5oC interval. The floor covering materials used in this experiment were mortar and 3 types of plywood with thickness of 2.7 mm, 7.5 mm, and 12 mm. The floor surface temperatures (tf) and the skin temperatures of 8 subjects were measured while they were sitting on the floor. Buttocks temperature was particularly monitored. This experiment yielded the following results: (1) The floor surface temperature (tf) was 17.0oC 35.2oC on mortar finishing and 19.1oC 30.2oC on 12 mm plywood covering. (2) The buttocks skin temperature increased at more than tsw 30oC on mortar finishing and 30oC, 25oC, and 20oC on 2.7 mm, 7.5 mm, and 12 mm plywood finishing, respectively (3) The differences of buttocks temperature between tsw 15oC and 40oC were 11.4oC on mortar, 7.9oC on 2.7 mm, 6.5oC on 7.5 mm, and 5.0oC on 12 mm plywood. (4) Using regression analysis, the neutral point temperature of buttocks was determined at 32.8oC.
¼ÒÀåó Çѱ¹»ýȰȯ°æÇÐȸ
¾ð¾î Çѱ¹¾î
¡á Á¦ 1 ÀúÀÚÀÇ ´Ù¸¥ ¹®Çå ½Äº°ÀúÀÚ´õº¸±â
°Ç°­ÇÑ Ã»³âÀÇ ´Ü½Ã°£ °øÇسëÃâ°ú ÀÏȸ¼º ¿îµ¿ÀÌ Æó±â´É°ú »ý¸®¹ÝÀÀ¿¡ ¹ÌÄ¡´Â ¿µÇâ
±è¹ÎÁÖ(Min-Joo Kim) ; ÀÌ´ëÅÃ(Dae-Taek Lee) ; ¼Û±¹¼·(Gook-Sup Song) ; ¹æ½Â±â(Seung-Ki Pang) - Çѱ¹»ýȰȯ°æÇÐȸÁö : Vol.22 No.1 (201502)
µµ½ÃÀÇ º¸Ç൵·Î ÁÖº¯ Ư¼º¿¡ µû¸¥ ¿©¸§Ã¶ ¹Ì¼¼±âÈÄ º¯È­
¼Û±¹¼·(Gook-Sup Song) ; ¾ÈŰæ(Tae-Kyung Ahn) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.20 n.7 (201312)
µµ½É º¸Çà·ÎÀÇ ³ìÈ­°¡ ¿©¸§Ã¶ ¹Ì¼¼±âÈÄ º¯È­¿¡ ¹ÌÄ¡´Â ¿µÇâ
¼Û±¹¼· - ´ëÇѰÇÃàÇÐȸ Çмú¹ßÇ¥´ëȸ ³í¹®Áý : v.33 n.2 (201310)
¹Ù´ÚÀÇ ¿Âµµ°¡ ½ÉºÎ¿Âµµ, ÇǺοµµ, Ç÷·ù·®¿¡ ¹ÌÄ¡´Â ¿µÇâ
¼Û±¹¼·(Gook-Sup Song) ; ¾È°¡¿¬(Ga-Youn Ahn) ; ÀÌÁ¤¹ü(Jeong-Bum Lee) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.18 n.1 (201102)
¹Ù´ÚÀÇ ¿Âµµ°¡ ½ÇÇèÁãÀÇ ¼ºÀå°ú ¹ø½Ä¿¡ ¹ÌÄ¡´Â È¿°ú
¼Û±¹¼·(Gook-Sup Song) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.17 n.3 (201006)
[ƯÁý] ±×¸°ºôµù°ú ¿Âµ¹ÀÇ ¿Â¿­È¯°æ
¼Û±¹¼· - ±×¸°ºôµù(Çѱ¹±×¸°ºôµùÇùÀÇȸÁö) : v.10 n.4 (200912)
ºÒ±ÔÀÏÇÑ ÈÖµµºÐÆ÷ÀÇ ±Û·¹¾î±¤¿ø¿¡¼­ ºÎºÐÈÖµµ°¡ ºÒÄè±Û·¹¾î°¨¿¡ ¹ÌÄ¡´Â ¿µÇâ
±è¿ø¿ì ; ¼Û±¹¼· - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : v.3 n.2 (200906)
ºÎ»ê½Ã ¿¡³ÊÁö¸¶Àϸ®ÁöÁ¦ ½Ã¹ü¿î¿µÀ» ÅëÇÑ °¡Á¤¿ë Àü·Â ¼ÒºñÀý°¨ È¿°úºÐ¼®
ÀÌÀºÁÖ ; ¹è¹ÎÈ£ ; ±èÀç¹Î ; ¼Û±¹¼· ; °û³ë¿­ ; ¿Á¼º¾Ö - ´ëÇѼ³ºñ°øÇÐȸ ÇϰèÇмú¹ßǥȸ ³í¹®Áý : (200906)
¿Â¿­»ý¸® ¹ÝÀÀ ÃøÁ¤¿ë Á¤¹Ð ¿Âµµ°èÀÇ °³¹ß
¼Û±¹¼·(Cook-Sup Song) ; Àå¹®³à(Moon-Nyeo Chang) ; ±è±âÈÆ(Ki-Hoon Kim) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.15 n.4 (200812)
¹Ù´Ú¿Âµµ¿Í ´ë»ç·®ÀÌ ³¶½ÉÀÇ ¿Âµµ¿¡ ¹ÌÄ¡´Â ¿µÇâ
¼Û±¹¼·(Gook-Sup Song) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.12 n.3 (200509)