°ÇÃ൵½Ã°ø°£¿¬±¸¼Ò

Architecture & Urban Research Institute

pdf¿ø¹®º¸±â ¿¡·¯ ÇØ°á¹æ¹ý ¹Ù·Î°¡±â



¹®ÇåȨ > Àú³Î > »ó¼¼

[¿ø¹®º¸±â½Ã ¼ÒºñµÇ´Â Æ÷ÀÎÆ® : 50 Æ÷ÀÎÆ®] ¹Ì¸®º¸±â

Çѱ¹»ýȰȯ°æÇÐȸ|Çѱ¹»ýȰȯ°æÇÐȸÁö 2002³â 3¿ù

±â»ç¸í [¿¬±¸³í¹®] ÁöÇÏö°ø°£ ¿­È¯°æÀÇ ½ÇÃø ¿¬±¸ / Examination of Thermal Condition of Subway Space for Utilization of Exhausted Heat from Subway
ÀúÀÚ¸í ÀÌö±¸½Äº°ÀúÀÚ
¹ßÇà»ç Çѱ¹»ýȰȯ°æÇÐȸ
¼ö·Ï»çÇ× Çѱ¹»ýȰȯ°æÇÐȸÁö , v.9 n.1(2002-03)
ÆäÀÌÁö ½ÃÀÛÆäÀÌÁö(74) ÃÑÆäÀÌÁö(5)
ISSN 1226-1289
ÁÖÁ¦ºÐ·ù ȯ°æ¹×¼³ºñ
ÁÖÁ¦¾î ; Unused Heat Source Utilization ; Subway ; Exhausted Heat ; Thermal Condition
¿ä¾à1 Unused energy sources like underground water, river water and exhausted heat from subway, have been used for the conservation of energy and earth environment. Thermal condition of subway space was examined for the basic materials of utilization of exhausted heat from subway by measuring air temperatures, air humidities, air velocities, wall temperatures etc. The air temperature at ventilation tower was about 15oC higher than outdoor air temperature in winter. This temperature difference seems to be sufficient for utilization as a heat source of heat pump. Moisture absorption was little during air inlet and air outlet in subway tunnel, so there are little possibility of enthalpy decrement according to air humidity decrease. As operation of ventilation fan scacely inflenced on the air velocity in tunnel, fan capacity increase for more heat recovery in ventilation tower will not have problem. Generally, heat movement is formed from tunnel air to tunnel wall. This phenomenon seems to be one of the reason for gradual air temperature increase of subway space.
¼ÒÀåó Çѱ¹»ýȰȯ°æÇÐȸ
¾ð¾î Çѱ¹¾î
¡á Á¦ 1 ÀúÀÚÀÇ ´Ù¸¥ ¹®Çå ½Äº°ÀúÀÚ´õº¸±â
°ÇÃà±â°è¼³ºñ°ø»ç ÇÏÀÚ»ç·Ê Á¶»ç¸¦ ÅëÇÑ ½Ã°ø°³¼± ¿¬±¸
ÀÌö±¸ ; ±èÁ¾´ë ; ÀÓżø ; ÃÖ¸í½Ä - Çѱ¹°ÇÃàģȯ°æ¼³ºñÇÐȸ ³í¹®Áý : v.6 n.2 (201206)
[ÀϹݿø°í] ¿¡³ÊÁöÀý¾à¡¤ÀÚ¿øÀý¾àÇü Ŭ¸°°øÁ¶½Ã½ºÅÛ °³¹ß
ÀÌö±¸ ; À̹οì - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.29 n.04 (201204)
[ÀϹݿø°í] °ÇÃà¿¡¼­ÀÇ °¡½ÃÈ­(ʦãÊûù)ÀÇ Á߿伺
ÀÌö±¸ ; À̹οì - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.29 n.02 (201202)
[ƯÁý] ±³À°½Ã¼³ÀÇ ¼³ºñ½Ã½ºÅÛ °èȹ
ÀÌö±¸ - ±³À°½Ã¼³(Çѱ¹±³À°½Ã¼³ÇÐȸÁö) : v.16 n.1 (200901)
BIPV ½Ã½ºÅÛÀÇ Â÷¾ç È¿°ú¿¡ µû¸¥ ÇÇÅ© ³Ã¹æºÎÇÏ Àý°¨È¿°ú¿¡ °üÇÑ ¿¬±¸
ÀÌÃæ½Ä ; ÀÌÀÀÁ÷ ; ÀÌö±¸ - ž翡³ÊÁö(Çѱ¹Å¾翡³ÊÁöÇÐȸ ³í¹®Áý) : v.28 n.5 (200810)
½Ç³»¿­È¯°æÀÇ ÃÖ±Ù ¿¬±¸µ¿Çâ¿¡ °üÇÑ °íÂû
ÀÌö±¸(Chul-Goo Lee) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.15 n.2 (200806)
¾î¸°ÀÌ Àü¿ëº´¿øÀÇ ¿­¿ø¼³ºñ ´ë¾Èº° Life Cycle Cost ºÐ¼®
¹æ½Â±â(Seung-Ki Pang) ; 俵ÅÂ(Young-Tae Chae) ; ÀÌö±¸(Chul-goo Lee) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.13 n.1 (200603)
¼³°è´Ü°è¿¡¼­ °ÇÃ๰ÀÇ Á¾ÇÕ¼º´É Æò°¡
¹æ½Â±â(Seung-Ki Pang) ; ¹é¿ë±Ô(Young-Gyu Baik) ; ÀÌö±¸(Chul-Goo Lee) ; Á¶Çö(Hyun Cho) - Çѱ¹»ýȰȯ°æÇÐȸÁö : v.12 n.4 (200512)
[ÀϹݿø°í] ¸ñ¿å½Ã¼³ÀÇ ÄèÀû¼º°ú ¾ÈÀü¼º
ÀÌö±¸ ; À̹οì - ¼³ºñ | °øÁ¶ ³Ãµ¿ À§»ý(Çѱ¹¼³ºñ±â¼úÇùȸÁö) : v.22 n.10 (200510)
Åë½Å±¹»ç°Ç¹° °øÁ¶¼³ºñ ±â±âÀÇ ½Å·Ú¼º Æò°¡ ¹× °íÀåÀ̷µ¥ÀÌÅͰ¡ ³ëÈĵµ Æò°¡¿¡ ¹ÌÄ¡´Â ¿µÇâ
°û³ë¿­(Kwak Ro-Yeul) ; ÀÌö±¸(Lee Chul-Goo) ; ¾Èº´¿í(Ahn Byung-Wook) ; À±¿µ¿ì(Yoon Young-Woo) - ´ëÇѰÇÃàÇÐȸ³í¹®Áý °èȹ°è : v.21 n.7 (200507)