한국생태환경건축학회|KIEAE Journal 2018년 6월

논문명 100% 에너지자립 제로에너지주택을 위한 비용효과적 신재생 설비시스템 최적구성에 관한 연구 / Cost-Effective Optimal Configuration of Renewable Energy Equipment System for 100% Self Sufficient Zero Energy House
저자명 최민주 ; 백영민 ; 윤종호식별저자
발행사 한국생태환경건축학회
수록사항 KIEAE Journal, Vol.18 No.3(통권 91호) (2018-06)
페이지 시작페이지(41) 총페이지(6)
ISSN 2288-968X
주제분류 환경및설비
주제어 100% 자립 제로에너지 주택 ; 태양광발전 ; 지열히트펌프 ; 공기식히트펌프 ; 전기난방 ; 경제성평가 ; 100% Self-sufficient ; Photovoltaic ; Ground source HP ; Air source HP ; Electrical Heating ; Economic analysis
요약2 Purpose: The domestic thermal insulation standard value has significantly increased to realize the Zero Energy House and many passive houses or zero energy houses are being built recently. Passive technology, which is represented by high thermal insulation and high density, shows relatively stable implementation by development of building materials and accumulated construction experience. On the other hand, there are not matured technologies for heating and cooling, hot water supply and ventilation including new and renewable energy. This study investigated the possibility of constructing optimal renewable energy and facilities system in terms of cost and effectiveness for zero energy houses that can achieve 100% of energy independence rate at current level. Method: The target building is a single story house with a floor area of 100 ㎡ located in Gyeonggi-do. Outer wall and roof floor are composed of 200mm SIP (Structural Insulation Panel) structure and window is vacuum window with U = 0.5 w/㎡℃. As a building equipment, this study considered following systems: ground source heat pump (GSHP), air source heat pump (ASHP), electric heating boiler (EHB), electric cable heating (ECH), electric air conditioner (EAC), solar domestic hot water system (DHWS), and solar PV. Finally, this study selected four combinations of systems (GSHP, ASHP+EAC, EHB+EAC, ECH+EAC) for the investigation. Result: This study assumed that all the loads in the building are covered by electric energy, and the calculation of the annual energy cost was based on the current electric charge system. Therefore, all loads are supplied by domestic electricity except GSHP. In addition, this study assumed that all renewable energy facilities for 100% energy self-reliance are supplied by solar power and then calculated the capacity to cover all household electricity with PV to derive the range of required PV capacity. Finally, this study calculated the initial investment cost range for each system configuration and the investment payback period, and determined the cost effective system configuration.
소장처 한국생태환경건축학회
언어 영어
■ 추천문헌 (이 문헌과 같이 본 문헌)
[특집] 국내 친환경 건축물 사례 분석
정지나 ; 김용석 ; 이승민 - 그린빌딩(한국그린빌딩협의회지) : v.9 n.1 (200803)
사례분석을 통한 제로에너지 건축물 인증 등급별 설계 요소와 공사비 분석
김미연(Kim, Mi-Yeon) ; 김형근(Kim, Hyung-Geun) ; 홍구표(Hong, Goopyo) - KIEAE Journal : Vol.18 No.2(통권 90호) (201804)
공동주택 제로에너지 건축의 핵심기술에 관한 연구
강기남(Kang, Ki-Nam) ; 박민주(Park, Min-Ju) - 대한건축학회 학술발표대회 논문집 : Vol.37 No.2 (201710)
[시론] 4차 산업혁명 시대, 건축의 대응
이명식(Lee, Myung-Sik) - 건축(대한건축학회지) : Vol.61 No.05 (201705)
국내 패시브건축물 설계 및 시공사례
이명주 - 한국그린빌딩협의회 추계학술강연회 논문집 : (200911)
독일 패시브하우스 단열 기준을 통한 국내 패시브하우스 사례 비교 분석
김주환 ; 이태구 ; 조경민 ; 김주수 - 한국생태환경건축학회 학술발표대회 논문집 : 통권18호 (201005)
[특집] 친환경 건축물의 개념 및 계획 방법
윤종호 - 건축환경설비(한국건축친환경설비학회지) : v.1 n.2 (200710)
건축물에너지효율등급 인증 현황 분석을 통한 제로에너지건축물의 설계 영향인자 분석
김진호(Kim, Jin-Ho) ; 조수영(Jo, Su-Young) ; 김창민(Kim, Chang-Min) ; 장향인(Jang, Hyang-In) ; 김선숙(Kim, Sun-Sook) - 한국건축친환경설비학회 논문집 : Vol.12 No.4 (201808)
냉각수 유량 제어를 통한 냉방시스템의 에너지 절감 효과에 관한 검토
김혜미(Kim, Hyemi) ; 송영학(Song, Young-hak) - 대한건축학회 학술발표대회 논문집 : Vol.37 No.1 (201704)
노원에코센터(제로에너지건물) 연간 에너지모니터링 결과 분석 연구
임인혁(Lim, In-Hyok) ; 이응신(Lee, Eung-Shin) ; 이명주(Lee, Myoung-Ju) - 대한건축학회논문집 계획계 : v.30 n.10 (201410)